Web Analytics Made Easy - StatCounter

Traction Motor Repair Tenders

Get complete information related to latest Traction Motor Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Traction Motor Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Traction Motor Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :40796667 Due date: 16 Jul, 202516 Jul, 2025 NA
Tender For supply, installation, foundation work, erection and commisioning of rotary screw electric dri ven air compressor cap-500 cfm, 10 kg/cm2. detailed specification as per annexure-a. supplyitem descri ption: supply & commissioning of electric air compressor of neutral screw type including air dryer, capacit y 500 cfm, working pressure-08-10 kg/ sq.cm, 3-phase, 415 v, with warranty/guarantee and test certificat e. required technical specification: 1. type of drive: gear drive, 2) type of prime mover: tefc (totally encl osed fan - cooled) 3) cooling system: air cooled 4) max pressure : 9-10 kg/sq.cm, 5) electric motor capacit y: 100 hp (min) 6) inter cooler / after cooler: finned & tube type of fin material- aluminium 7) no. of phas es: 3 phase with neutral 8) discharge air purity in respect of humidity, liquid water & solid particles: class- 1 as per iso 8573-1 9) compressor - isi marked to is: 5456. [ warranty period: 30 months after the date of delivery ]

State Government

CTN :40756934 Due date: 02 Jul, 202502 Jul, 2025 10.04 Lacs
Tender For supply and installation of some articles to the residential office of the honble deputy speaker, tripura legislative assembly, bardowali, agartala during the year 2025-26 - providing of split type high wall 2.00 tr (rated cooling capacity should not be less than 6,000 kcal/hr or 24000 btu/hr or 7000 kw) split a.c. machine with inverter compressor technology operating on non-cfc refrigerant (r-410a/r-32/equivalent refrigerants) suitable for wall mounting conforming to is:1391 (part-ii) specification (evaporator & condenser must be of pure copper) not less than 3 (three) star rating (latest standard), operates on single phase 230 volt, 50hz, ac supply maximum current drawn 11.0 ampere, including supply of 3.0 mtr copper pipe (both for suction & liquid line), 3.0 mtr 4 (four) core electrical connecting cable, remote control unit in/c batteries, 16 amps power top etc complete, capable of performing a) cooling b) dehumidifying c) air circulation d) filtering as per direction of the engineer-in-charge., standard installation of 1.5 tr/2.00 tr capacity high wall split air conditioner i/c providing of electrical plug top of required capacity, flling up/ repairing of drilled portions by cement mortar, painting etc. as per direction of the engineer-in-charge., fabrication of m.s. platform for placement of condensing unit by using m.s. angle of (50x50x5) mm size base plate, nuts & bolts or cradle of suitable sizes i/c painting, fitting, fixing grouting by cement mixer as per direction of the engineer-in-charge., providing hard pvc pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the engineer-in-charge., supply and installation of additional length of copper pipe of suitable diameter for suction and liquid line between indoor and outdoor units (for 1.5 tr & 2 tr ac) beyond the standard length as per direction of the engineer-in-charge. (if required), providing and connecting electric control cables between mcb to indoor/outdoor. 3c x 2.5 sq. mm copper cable., supplying & fixing of 1200 mm sweep white color ac ceiling fan capacitor type double ball bearing complete with 300 mm down rod, canopies, shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm pvc insulated copper conductor cable(fr) (isi marked, bee 1 star/minimum service value 4.0 m /min/w): -, supplying and fixing of 20 mm dia extra down rod (gi pipe medium guage) with necessary hole for installation of ceiling fan as required., wiring for light/fan/ exhaust fan/ call bell point with 2x1.5 sq. mm pvc insulated copper conductor cable (fr) in pvc conduit (medium gauge) recessed in slab/ walt complete with 6/10 amps modular type switch, cover plate, gl box including necessary connection etc. as required, supplying and fixing of the following modular accessories including necessary connection etc. as required 3/6 pin 16/20 amps socket outlet (2m), supplying and fixing of the following modular accessories including necessary connection etc. as required4 step fan regulator (1m), supplying and fixing of the following modular accessories including necessary connection etc. as required20/25 amps single phase motor starter switch (2m), wiring for circuit/sub-main with the following sizes pvc insulated copper conductor cable (fr) in pvc conduit (medium gauge) recessed in slab/ wall etc. as required, earthing with 40 mm dia g.i. earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top cl cover plate size 12"x 12" having locking arrangement including cc work, holes on earth pipe etc. as required, proving and fixing/drawing of 4.06 mm dia (8 swg) g.i. 10 wire on surface or in existing g.j/pvc/ polythene pipe for loop earthing as required., executive desk with return unit, size: 2100(w)x 2250(d) x 750 (h) mm, executive revolving chair, visitor chair, godrej 4 door bookcase (1742 h x 914 wx 320 d) mm

Central Government/Public Sector

CTN :40772721 Due date: 11 Jul, 202511 Jul, 2025 NA
Tender For supply of elgi make screw compressor spares > - consumable spares list, air filter element, oil filter, element separator (e90-160), minimum pressure valve kit, intake valve kit (e132-160), coupling element e90-160, blow down valve kit, pressure transmitter, temperature sensor, air inlet system, nc intake valve 4 inch hpkg-120, ss t bolt clamp jt6a20-dia 170, elbow; rubber 6 , indicator: air filter clog, drive coupling,dia 80/60, a/e pkg gr:1.326 axis 284, connector; pvc hose 3/4", steel reinforced pvc hose 60mm, after and oil cooler assy-e-160, base assembly-e160, bracket - airend, vertical tank e132-e160, hose-3 inch discharge, bracket air filter assy, filter head 360 lpm machining, dia 550 pusher fan 400v, oil return line assembly, exhaust fan 6" sq 220v, pressure regulator prne, ball valve 3, hose set e90-e160 wc (4nos), filter assy. -360 lpm, fan dia. 42" with hub ee160, steel reinforce pvc hose 20mm gre, o/c &a/c assy ee160 alu.coler, tank rec e90-e160 horizone, pipe assy mpv hose to cool, hose assy mpv to cooler, pipe with elbow assy, hose assy 1 1/2 tv to oil out, hose assy tv to oil in, pipe with flange assy, pipe tee assy, hose with metallic bellow 32nb, hose assy airend to tank, hose assy 1 1/2 tank to tee, air end package 1.11: 1, steel reinforce pvc hose 10mm gre, steel reinforce pvc hose 20mm gre, steel reinforce pvc hose 50mm gre, control system of model e90- e160, hex reducing nipple 1/4 (m) x 1/8 (m), pr regulator, tms elbow x (t), tee pipe , tms coupling x (t), hex nipple , connector hose adapter , hose x 1000l (e132-160), tube 2 mts, spares for compressor of model e132- e160, base & drive system, anti vibration mount - e132- e160, cooling and lubrication system 90-160 wc, o ring 54.2 x 47.2 x 3.5, element, therm valve 155 deg, elbow tms 1 x 1 , tee; pipe; npt, pr transmitter 16 bar, 4.20 ma, filter oil, oil filter indicator, nipple; hex; npt, seperator element 1200 cfm, gasket flange 2 for e160-8 bar, mpv with check valve -mpvl65, pr. releif valve, plug, hex 1 npt, oil sight glass, nipple ; pipe; npt x 300, elbow tms x npt, transparent tube 8x6 1.2, coupling; tms; 1/4 x1/8 npt, o ring id 80.0x2.5 thick, hex nipple, tee pipe, pressure switch 0.2-7.5 bar, pressure guage, spares for compressor of model e75-85, consumable spares list, neuron ii, air filter element, oil filter, element seperator, minimum pressure valve kit, intake valve kit, pr. regulator, coupling drive (or) coupling element, pressure transmitter, temperature sensor, hose assy-a/e to tank, blowdown valve kit, actuator kit, oil sight tube6mmx 4mm - 0.5m, ferrule 6 mm, pipe sets dis sys e75-horizon, pipe assy mpv to hose, hose assy mpv to cooler, pipe assy ms to ball valve, discharge hose, hose oil line, fan assy 23 inch, air inlet & control system, 5/8 x m10 bush reducer, intake valve nc, hex nipple x 1/8 npt, pressure regulator, tee branch x npt, tubing 6mm 1.5m, coupling tms x 1/8 npt, connector npt, ss t bolt clamp dia 170, connector rubber 6 , rubber hose duct connector, ss t bolt clamp, elbow npt, elbow tms x npt, temp sensor, discharge system, tms elbow, minimum pressure valve, water seperator, hose mpv out to ac, scavenging line pipe, tms elbow npt, tms elbow, pressure releif valve 1 npt, o ring, hex reducing nipple, assy strainer, tms elbow, hose assy 80 nb, hex plug 1 npt, oil sight glass tube 0.5m, pipe nipple npt, tube nylon 6x4 1.5m, tms elbow, seperator, pressure transmitter, cooling system, oil cooler & after coller assembly, fan motor 2 hp, lubrication system, elbow 1 x m42, pipe tank to tv, tee branch 1 npt, spin on filter, filter head, element thermal valve, housing thermal valve 1 npt, swivel elbow connector 1 npt, pms coupling 1 bsp x 1 od, swivel elbow connector 1 bsp x 1 od, swivel banjo connector m27 x 2, motor and base assembly system, coupling drive, anti vibration mount motor, anti vibration mount airend, recommended spares for e18-e22 & & e30-e7.5 ac 415v for horizon series kit of spares upto 2500

State Government

CTN :40780333 Due date: 09 Jul, 202509 Jul, 2025 30.54 Lacs
Tender For e-206/1/2025-estate/rate contract for supply of a.c. items for estate dept of nia jaipur/2025-26 - a.c. items, supplying of r-22 refrigerent gas, maflon/freeon/floron & equilent, supplying of r-32 refrigerent gas,maflon/freeon/floron & equilent, supplying of r-410 refrigerent gas, maflon/freeon/floron & equilent, supplying of copper pipe inch (12.7 mm), total line/max flow & equilent, supplying of copper pipe inch (6.4 mm), total line/max flow & equilent, supplying of copper pipe 3/8 inch (9.5 mm) , total line/max flow & equilent, supplying of copper pipe 5/8 inch (15.9 mm) , total line/max flow & equilent, supplying of insulation seleve (1 box : 200 pcs) (15.9 mm), supremen/total line/armaflex & equilent, supplying of insulation seleve (1 box : 200 pcs) (3.8 mm), supremen/total line/armaflex & equilent, supplying of insulation seleve (1 box : 200 pcs) (12.7 mm) , supremen/total line/armaflex & equilent, supplying insulation seleve (1 box : 250 pcs) (6.4 mm) , supremen/total line/armaflex & equilent, supplying of drain pipe 19 mm, any good quality, supplying of breezing rod, any good quality, supplying of maascule tape (black colour) , any good quality, supplying of maascule tape (white colour) , any good quality, supplying of electric tape (1 box : 30 pcs) steelgrip, any good quality, supplying of single phase contactor 220 walt , any good quality, supplying of lpg cane (1 box : 30 pcs) , any good quality, supplying of brizing torch (double barrel) , any good quality, supplying of service jacket 48 inch (reflective), any good quality, supplying of service jacket 54 inch ( reflective) , any good quality, supplying of vacume pump single stage , any good quality, supplying of vacume pump double stage , any good quality, supplying of pvc salution tube , any good quality, supplying of taflon tape, any good quality, supplying of pin valve, any good quality, supplying of flayer nut 5/8 inch, any good quality, supplying of flayer nut inch, any good quality, supplying of flayer nut inch, any good quality, supplying of ptc relly , any good quality, supplying of ac service pump 1800 watt, any good quality, supplying of mini fold guage, any good quality, supplying of clamp meter, any good quality, supplying of 8 mm fastner (1 box : 50 pcs) , any good quality, supplying of empty refrigerator gas cylinder (60 kg.), any good quality, supplying of capacitor 50 + 4 mfd, any good quality, supplying of 2.5 sqmm three core frls pvc sheathed flat flexible copper cable as per is:694-2010., polycab/havells/kei/rr & equilent, supplying of 2.5 sqmm four core frls pvc sheathed flat flexible copper cable as per is:694-2010., polycab/havells/kei/rr & equilent, supplying of inlet copper tube spring bender for 1/2 inch copper pipe, polycab/havells/kei/rr & equilent, supplying of inlet copper tube spring bender for 5/8 inch copper pipe, any good quality, panasonic/voltas/hitachi/carrier/daiken/l.g./toshiba split ac 1.5 ton, indoor pcb, outdoor pcb, indoor sensor, outdoor sensor, indoor motor, outdoor motor, compressor, cooling coil, condensor coil, fan blade, panasonic/voltas/hitachi/carrier/daiken/l.g./toshiba split ac 2 ton, indoor pcb, outdoor pcb, indoor sensor, outdoor sensor, indoor motor, outdoor motor, compressor, cooling coil, condensor coil, fan blade, electrolux/videocon window ac 1.5 ton, cooling coil, condensor coil, fan blade, motor, compressor, sensor, grill, blue star 3 ton tower ac(tonner capcity 750 grams, printing 15000 pages), pcb, single phase previnatum, contactor 3 phase, outdoor motor, indoor motor, indoor sensor, fan blade, voltas 4 ton tower ac, pcb, single phase previnatum, contactor 3 phase, outdoor motor, indoor motor, indoor sensor, fan blade, casate ac daiken 2 ton(tonner capcity 120 grams, printing 1500 pages), pcb, blower motor, outdoor motor, sensor, drain pump, fan blade, casate ac voltas 3.5 ton, pcb, blower motor, outdoor motor, sensor, drain pump, fan blade

Central Government/Public Sector

CTN :40566409 Due date: 27 Jun, 202527 Jun, 2025 NA
Tender For corrigendum : supply of bearings for fd los lt motor-3.7 kw , bearings for id los lt motor-30 kw , bearings for pa los lt motor-5.5 kw , bearings for cs air fan lt motor-7.5 kw , cooling fan for fd los lt motor-3.7 kw , cooling fan for id los lt motor-30 kw , cooling fan for pa los lt motor- 5.5 kw , cooling fan for cs fan lt motor- 7.5 kw , motor terminal block for lt motor-3.7 kw , motor terminal block for lt motor- 30 kw , motor terminal block for lt motor-5.5 kw , motor terminal block for lt motor-7.5 kw , bearings for lt motor of cs fan-7.5 kw , cooling fan for ltm of cs fan-7.5 kw , motor terminal block for lt motor-7.5 kw

CTN :40790011 Due date: 11 Jul, 202511 Jul, 2025 12.55 Lacs
Tender For procurement of four 04 number cooling tower fan motor 415v 110kw for stage i under emoph department sgtpp wbpdcl

Central Government/Public Sector

CTN :40781272 Due date: 23 Jun, 202523 Jun, 2025 NA
Tender For cooling fan for three phase induction motor(25hp) suitable for abb make motor to part no- 3 gzv 304 014-3. one sample should be got approved before effecting bulk supply. [ warranty period: 30 months after the date of delivery ]

Central Government/Public Sector

CTN :40753627 Due date: 21 Jun, 202521 Jun, 2025 1
Tender For repair, maintenance, and installation of plant/ systems/equipments (version 2) - office space; repair/ renewal service of various office assets; service provider-the ro purifier/ plant in rest room not absorbing water view suspected r0 01 job membrane worn out/ defective. same is to be replaced/ renewed including qty the ro-cum-water purifier in dsc block damaged and motor with coil burned 01 job out due to power fluctuation including adapter damage with suction pipe. the ro cum purifier to be repaired with replacement of burned motor and adapter including complete servicing and proving. (e)exhaust fan motor of pantry worn out due to ageing and not working. same to 01 job be replaced/ renewed and refitted for satisfactory working including set up and renewal of various electrical fittings. heavy noise observed in 1.5 ton split ac of ops room with continuous seepage 01 job of water. the outdoor unit of the ac malfunctioning due to outdoor pcb unit damage view short circuit. the pcb to be replaced and cooling unit (internal unit) to be cleaned/ serviced for satisfactory working with proving including internal wiring job and refilling of gas (r 410). cooling unit of the split ac at mt section not working due to gas exhaustion. 01 job gas to be refilled with servicing of the unit. the doutble door refrigerator of pantry not working due to defect and damage 01 job in pcb and compressor found malfunctioning. the colling effect not satisfactory. the pcb and compressor to be rectified and replaced with filling of r 134 gas. same to be proved for satisfactory working. additional terms and conditions officer's washroom various fitments viz. showers, mirrors, wash basin, soap 01 job stand, curtain rod and 03 in no. conmmodes deteriorated. to be renewed as per sample. in addition the 02 ceiling light broken and uprooted from base of ceiling. to be renewed and replaced with wiring from sockets..

CTN :40717669 Due date: 05 Jul, 202505 Jul, 2025 NA
Tender For supply of repair of 30 kva gen set cooling fan and motor repair , repair of 30 kva gen set self starter , repair of 30 kva gen set head , repair of 30 kva gen set alternator , repair of 30 kva gen set ac output , repair of 30 kva gen set blower

CTN :40703879 Due date: 04 Jul, 202504 Jul, 2025 2.00 Lacs
Tender For supply of repair of 2 ton split ac , filling of gas , replacement of capacitor , replacement of pcb , repair of leakage in cooling , repair of compressor fan , welding charges , fitting charges , rewinding of cg power motor , repair of refrigerator , repair of mixer grinder , repair of induction cooker
 Loading, Please wait...

Connect us via What's Up