Tender For corrigendum : design, supply, installation, testing and commissioning, training and camc of x-ray baggage scanner, door frame metal detector (dfmd), hand held metal detector (hhmd), q-managers and ladies frisking booth for metro stations of nagpur metro rail pro - supply, installation, testing & commissioning, training and camc of x-ray baggage scanner, door frame metal detector (dfmd), hand held metal detector (hhmd), q-managers and ladies frisking booth for metro stations of nagpur metro rail project phase-ii
Tender For construction of heliport at jaskot tehsil and distt. hamirpur (h.p) (sh- supply, installation, testing and commissioning dual view x-ray baggage scanner, door frame metal detectors and hand metal detectors therein)
Tender For : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of spares for diese
Tender For procurement of modern gadgets for ks&dl security department - x-ray baggage scanner(paradigm make x-ray baggage scanner with ai feature pts-5030 ai tunnel size- 500mmx300mm, door frame metal detector(paradigm make eighteen zone door frame metal detector model no-pts -mzmd-018), hand held metal detector (paradigm make hand held metal detector model no-pts-003, boom barrier, breathing analyzer
Tender For request for proposalselection of agency for supply, installation, testing & commissioning (sitc) ando&m of adaptive traffic control system (atcs) and trafficenforcementsystem(tes) in gandhinagar city (2nd attempt)
Tender For annual rate contract for year 2026 - 2027 material supply & maintenance for existing c.c.t.v. security surveillance systems, hand metal, doors frame metal detector, walky-, talky, l.e.d. screen & tv, sound pa system, luggage scanner & intercom system at ambaji temple at gujarat, india” (estimated annual value 20.00 lacs)
Tender For tggenco ytps c andi unit4 assembling or dessembling , cleaning ,purging , testing, servicing, calibration and refixing of c and i equipments or instuments of main boiler , boiler auxiliaries id, fd, pa fans and lubeoil systems, blade pitch control dampers, guns and igniters, flame scanners, fuel oil valves and solenoids and instrumentation pertains to bowl mills,hot air and cold air gates of all mills, mill rejection system and gravimetric feeders, seal air and scanner air fans , sadcs power cylinders, smart positioners, transmitters, solenoid valves , limit switches, o2 analysers, aslds,seals replacement of pneumatic cylinders of had,cad,idf,paf,fdf dampers, burner tilt, movs pertaining to flue gas path gates and boiler valves, seperators and hwl valves, eco flow valves , bcw pumps, aph scaph system, soot blowing system, ervs, metal temperatures, flue gas temperatures, pressures and analysers and replacement of spare parts in unit 4 from commencement to 31.3.27