Tender For shock pulse meter fortraction motor bearing testing with shock pulse measurement, vibrati on measurement of all three parameters(displacement,acceleration, & velocity), laser tachometer measure ment, stethoscope for easy location of machinery noise, lcd display, along with standard supply: shock puls e probe, head phone, vibration sensor, powerfull magnetic base,hand held probe rod, cable with cannectors, laser tachometer probe,charger,instrument manual. detailed specification as per specification no: clw/tm/4 111/24-25/029 dated 15/01/2025.make/brand: spm/mcm/skf/fluke. [ warranty period: 30 months after t he date of delivery ]
Tender For supply, installation, testing and commissioning of digital coating thickness gauge for all m etal substrates (elcometer, for both ferrous and non-ferrous materials with external probe for measurement of galvenization of item no. 2 above), high contrast color display, automatic base material identification, m easuring principle eddy current & magnetic induction method, resolution 0.1 micrometer, measuring rang e 0 -1250 micrometer, supplied with certificate of calibration [ warranty period: 30 months after the dat e of delivery ]
Tender For supply, installation, testing and commissioning of digital coating thickness gauge for all m etal substrates (elcometer, for both ferrous and non-ferrous materials with external probe for measurement of galvenization of item no. 2 above), high contrast color display, automatic base material identification, m easuring principle eddy current & magnetic induction method, resolution 0.1 micrometer, measuring rang e 0 -1250 micrometer, supplied with certificate of calibration [ warranty period: 30 months after the dat e of delivery ]
Tender For corrigendum : supply of surgical consumables items - b.p. cuff adult b.p. apparatus, b.p. cuff for automatic bp apparatus m size peadiatrics, b.p. cuff for automatic bp apparatus s size infant, b.p. cuff for automatic bp apparatus ss size neonates, b.p. cuff for manual bp apparatus l size peadiatrics, b.p. cuff for manual bp apparatus m size peadiatrics, b.p. cuff for manual bp apparatus infant s size peadiatrics, b.p. cuff for manual bp apparatus infant ss size, b.p. instrument mercury free (isi mark), bipap mask for non-invasive ventilator, battery for monitor (philips goldway g30), battery for monitor (philips gs20), ecg clamp set for ecg machine, ecg electrode, ecg electrode with blub for ecg machine, ecg gel 250ml, ecg lead for computrised for edan and bpl ecg machine, ecg lead for multipara monitor (goldway-g30 and gs20 philips), ecg roll bpl 6108 foldable, ecg roll bpl 9108 straight, ecg roll bpl-9108d, eeg conductive paste (450gms) jar, eeg gold plated electrods (25 nos. each set), flow sensor sle 5000 ventilator re-usable, hfnc filter for airwo 2, hose pipe for multipara monitor, laryngoscope bulb (white light), nibp cuff for multipara monitor, o2 flow meter (for o2 cylinders) (calibrated from 0-15 lit/min- unit with pressure gauze), o2 flow meter with humidifier bottle (for o2 cylinders) (calibrated from 0-15 lit/min- unit with pressure gauze), o2 mask adult (light weight, tranparent), o2 mask paediatrics (feathered edge for patient comfort- - nose clip -pull through adjustable elastic band), oxygen sensor for dragar ventilator, oxygen sensor for aeonmed ventilator, oxygen sensor for bel ventilator, oxygen sensor for meditec england allied ventilator, pulse oxymeter probe spo 2 measurement, spo2 probe for multipara monitor, thermal print roll 57mm x 30 mtrs., ultra sound gel 250ml (bottle water soluble, usg print roll type-i normal size 11mm x 20m (sony make)
Tender For supply and installation and commissioning of spm analyzer - supply, installtion & commossioning of spm analyzer with tuv. as per specifications, the system should have the below features as desired by cpcb.a) the spm analyzer should have continuous quality check for zero and spa point, prferably without human intervention to ensure continuous daya validity and credibility. (please refer guidelines for continuous emission monitoring system july 2017 page 8/100)b) the system should have feature of automatic range setup.c) the system does not required manual adjustment and should operate without any human intervention.d) the system should have autotic drift compensation.e) the system doen not have optical windows to be cleaned.f) the system should not required any alignment for smooth operation.g) the system doen not have any effect of vibrations on the system accuracy and readings.h) the system should have tuv with qal (en15267 parts 1 to 3) with appropriate certification range as per cpcb guidelines.measurement principle: inductive electrificationmeasurement objects: solid particles in a gas flowparticle size : 0.3 um or largermeasurement range: approx 0.1 mg/m3 to 1 kg/m3probe length: as per requirement (standard 500,750,1000,1500,2000 mm)probe dia: 10 mm, max temperature: upto 300 degree c. (optional upto 700 degre c)max pressure: 3 bargas velocity: min 4 m/sresponse time: less than 1 secondself zero span check: yessignal averaging: adjustable 0-300 seondoutput signals: isolated 4-20 ma serial communicaiton rs-485 modbus - two spdt relays:5a-24 vac/dcambient temperature: 20 to +60 degree chumidity: 95% rh (non- condensing)vibration: 5 m/s2 or lessprobe: ss316 linsulation of probe: peekenclosure: aluminmb alloypower supply: 230 vac, 15 vac, 24 vdcpower consumption: 3 wprotection: ip65certification: tuv with qal1, chief engineer
Tender For non-destructive examination of various equipments and process piping at hwpk site during mta-2025 - ultrasonic flaw detection of weldments on towers, tanks, equipment, nozzles, large dia gas lines and process pipe lines as per standard practice using reputed make ut flaw detector probes by asnt/isnt ut level ii/iii qualified and experienced persons including surface preparation with pre/post cleaning of weldments, interpretation of data and submission of reports., ultrasonic flaw detection of weldments on towers, tanks, equipment, nozzles, large dia gas lines and process pipe lines as per standard practice using reputed make ut flaw detector probes by asnt/isnt ut level ii/iii qualified and experienced persons including surface preparation with pre/post cleaning of weldments, interpretation of data and submission of reports., thickness measurement/mapping with grid marking at identified locations of xu towers/tanks and piping using standard ut thickness gauges and probe by asnt/isnt ut level ii/iii qualified and experienced persons including surface preparation with pre/ post cleaning, interpretation of data and submission of reports., phased array ultrasonic testing/time of flight diffraction of weld joints of exchange unit towers / tanks /pipelines as per standard practice using standard equipment and probes by asnt/isnt ut level ii/iii qualified and experienced persons including surface preparation with pre/post cleaning of weldments, interpretation of data, preparation and submission of reports ., liquid penetrant testing of weldments of heat exchangers, stiffening rings, equipment skirt/saddle supports, equipment nozzles d of xu towers, tanks and weldments of pipe lines (including supply of consumables and dp kit) by asnt/ isnt lpt level ii/iii qualified and experienced persons including surface preparation with pre/post cleaning of weldments and submission of reports, liquid penetrant testing of weldments of heat exchangers, stiffening rings, equipment skirt/saddle supports, equipment nozzles d of xu towers, tanks and weldments of pipe lines (including supply of consumables and dp kit) by asnt/ isnt lpt level ii/iii qualified and experienced persons including surface preparation with pre/post cleaning of weldments and submission of reports, long range ultrasonic testing (lrut) of process liquid piping and large dia gas piping connected to tower and tank with in 1st isolation valve of size from 4 inch nb to 36 inch dia.
Tender For item wise procurement and supply of laboratory items for a period of 12 months - equipments, digital turbidity meter/ nephelometer -(a).parameter range- 0 to 200 & 200 to 1000 ntu*. (b). readability - 0.1 ntu & 1.0 ntu. ( c). accuracy - 3% of range. (d). repeatability - 2% of range. (e). light source - tungsten halogen lamp. (f). detector - photo diode. (g). data presentation - 31/2 digit 7 segment led of 12.7 mm height. (h). accessories - matched test tubes- 5 nos. (i). useful for determination of sulphate, phosphate, chloride, zn, ag, etc. by astm procedure. (j). extendable for measurement of inhibition growth of semantic microbial agent .brands-systronic,techlab,elko, digital conductivity meter with conductivity cell type cc-03b. (a). conductivity range : 0 to 20,200 m s*, to 2,20 & 200 m s*, (b) readability : 0.05% of range, (c) accuracy ; +_1% of range, (d) repeatability;+_1% of range, (e) data presentation: 31/2 digit 7 segment led of 12.7 mm height, (f) operating frequency: 1000hz, (g) temp. compensation: 0 to 500 c manual, (h) cell constant: 0.05, 0.1 or 1.0 (selectable), (i) out put: 20mv full scale into 10kz resistive impedance, (j) accessories: cell stand with cell holding clip.brands-systronic,techlab,elko, digital ph meter with combined ph electrode type cl - 51b (a). ph range: 0 to 14, +_1999 emf (mv), (b) readability : 0.1 ph, 1emf(mv), (c) accuracy ; +_0.01 ph, +_1 emf (mv), (d) repeatability;+_0.01 ph, +_1 emf, (e) temp. compensation: 0 to 1000 c manual, (f) data presentation: 31/2 digit 7 segment led of 12.7 mm height with polarity, (g) accessories: stand with electrode holding clamp, buffer tablets and polythine bottle, (h) physical dimensions: size 295 x 165 x 140 & weight - approximate 3, (i) manual 2 point calibration for ph, digital salinity meter (micro processor based water analyzer with magnetic stirrer), (a) measures directly ph, emf, temperature, electrolyte conductivity(ec), total dissolved solid (tds), dissolve oxygen (do), sanitary colorimeter (abs & %t) and turbidity in water sample one at a time. (b) data presentation: 2 lines 16 character dot matrix lcd modules, (c) light weight portable and easy to carry on field, (d) operates on rechargeable battery & mains supply, (e) ph: range- 0-14, readability- 0.001, accuracy - +_0.001,repeatability - +_0.1, (f) emf (mv): range- +_1999,9, readability - 0.1, accuracy - +_0.1, repeatability- +_0.1, (g) temp: range - 0-1000 c, readability - +_0.1, accuracy - +_0.5, repeatability - +_0.1, (h) ec; : range - 0-200 ms (5 ranges), readability - 0.05% of range, accuracy - +_0.1 of range, repeatability - +_0.5% of range, (i) tds: range- 0 to 100 ppt 5 range with pds factor 0.5, readability - +_0.05% of range, accuracy - +_1% of range, repeatability - +_0.5% of range, (j) do: range - 0-20, readability - 0.1, accuracy - +_0.1, repeatability - +_0.1 (k) colorimeter: range- +_2 abs & 0 to 100% t, readability - 0.001, accuracy - +_0.05 abs, repeatability - +_0.01 abs, (l) turbidity: range - 0 to 100 ntu, readability - 0.001, accuracy - +_2%, repeatability - +_0.1% (m) salinity ranger: 0 to 40 ppt, accuracy - +_1%, temp, compensation - 0 to 500c, sensor- ise (chloride) & re- bnc, (n) accessories: ce, dip type conductivity cell of 1.0 cell constant, do probe, thermo probe, magnetic stirrer, mains operated electromagnetic stirrer gi 631, stirring capsules, electrode stand with holding clamp, gas permeable membranes and 10mm & 30mm test tubes., zerological water bath superior quality(manufactures specification should be uploaded), ph meter (pocket type), brands-tamp,techlab,scientix, tds meter (pocket type) ,brands-tamp,techlab,scientix, magnetic stirrer superior quality (manufactures specification should be uploaded), heating mantle superior quality (manufactures specification should be uploaded), rainguage with measuring cylinder superior quality (manufactures specification should be uploaded), water purifier (dew drops)superior quali