Get complete information related to latest Training Wall Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Training Wall Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Training Wall Tenders.
Tender For corrigendum : reconstruction/repair of civil structures and laying of damaged rising main and distribution at various locations under sassci work wise details given annexure i - restoration works of jal shakti (phe) city division no.i including reconstruction / repair of civil structure and laying of damaged rising main and distribution at various locations uinder sasci (phe sector). name of works:a.restoration of rising main and washed away supports of 8" rising main in lower roop nagar. b.damage of compound wall at tibba section of sub- division dhounthly. c.constuction of main gate / barbed wire fencing / road/ wall damaged near gsr 22.50 lacs glns at lohar station. d. restoration of boundary wall, roof and floor of the pump room building at phase iind muthi pumping station. e. improvement / restoration of damage chain link fencing around intake structure at cps nai muthi. f. construction of protection work to protect tube well and pump room at muthi left and muthi 6 and muthi 7 tube well at cps nai basti. g. providing and laying damage rising main at tube well muthi left, tube well no.6 and tube well no.7 nai basti at cps nai basti. h. repairement of the tube well buildings at muthi left, muthi 6, muthi 7 and cps naibasti. i. raising of udheywala station and construction of manifold and allied works of welding at tube well no.5 udheywala and suryavanshi nagar station of sub-division muthi. j. uplifting the central pumping station samadhian by way of shifting civil, electromechanical infrastructure of sub-division dhounthly under phase 1st. k. uplifting the central pumping station samadhian by way of shifting civil, electromechanical infrastructure of sub-division dhounthly under phase 2nd. l. uplifting the central pumping station samadhian by way of shifting civil, electromechanical infrastructure of sub-division dhounthly under phase 3rd. m. construction of 200000 glns sump tank at cps samadian. n. shifting of pipe utiliies at brick klin tube well and its allied works. o. reconstruction / repairment of bath room at sub-division dhounthly and muthi. p. restore the front area by way of laying paver blocks at cps gujjar nagar. q. erection of truss over the damage roof top central pumping station cps muthi goan. r. erection of truss over the damage roof top central pumping station and dismentaling of staff qtr at station cps gujjar nagar. s. reconstruction of damage operator qtr at cps gujjar nagar under dhounthly sub-division.
Tender For corrigendum : repair / maint of floor tiling , wall tiling, roof false ceiling, plinth protection , plaster kitchen bath wc, pressed steel, chaukhat and connected works of dibrugarh, chaubua and ganeshbari area under ge dinjan no 2
Tender For vertical extension on existing g plus floor bharat ratna abdul kalam boys hostel building rcc framed structure from 5th to 9th floors completion of hostel rooms in all respect in 5th and 6th floors including water supply sanitary installations and drainage and construction of a fire escape lift with lobby from ground floor to 9th floor and providing iei and fans dbs ug cables earthing and lighting protection manual fire alarm system and fire extinguishers extension of firefighting with down comer system upgradation of manual fire alarm system upgradation of existing 13 passenger lift 16 passenger fire man lift 20 kva ups system cctv system lan networking system and solar hot water system etc in indian institute of information technology design and manufacturing iiitdm kurnool campus at jagannatha gattu hill dinnedevarapadu kurnool district andhra pradeshsubwork/packages:providing additional light or fan or call bell points power points wall mount fans replacement of ups batteries installations of ac unit in the office of ee c cpwd at iiitdm campus kurnool
Tender For providing grouting to dam body, curtain grouting to drainage gallery, treatment to river trainingwall of kabini dam under drip phase-ii (package-1)
Tender For ca no. ge af no.1 / gur-32 / 2026-27 repair to floor, sanitary fittings, internal water supply, plinth protection, wall and other allied works in airmen mess, sncos mess, dsc line, dsc md accn, madhur milan, offrs mess, civ quarters, smq at 13 brd - : repair to floor, sanitary fittings, internal water supply, plinth protection, wall & other allied works in airmen mess, snco's mess, dsc line, dsc md accn, madhur milan, offrs mess, civ quarters, smq & offrs living accn area of 13 brd and 16 brd at af stn palam under ge (af) gurgaon no. 1
Tender For maint and repair of street lights security lights and solar lights and its connected items including repair to lt distribution network at mh and 41 arty div under ge mh and rh khadki - taking down old unserviceable lt ug cables of size upto 50 sq mm from trenches / poles / ducts etc complete all as specified and directed., supplying, laying, jointing, commissioning and testing xlpe insulated screened pvc bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade confirming to is-7098 (part-i-1988) laid in trenches/ducts/wall / floor / pipes/ poles including cable glands and aluminium lugs of appropriate size, pvc sleeve etc complete all as directed by engr in -charge for following sizes . make :- polycab/havells / gloster / finolex note :- earth work , bricks , riddled earth , gi pipe for protection of cable will be measured & paid under relevant items of schdule . , 50 sq mm 3.5 core ., 35 sq mm 3.5 core, 25 sq mm 3.5 core, 16 sq mm 4 core., 10 sq mm 2 core, 6 sq mm 2 core, excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5mtr in depth for foundation of poles stays laying of electric cables, pipes etc and getting out in soft/loose soil complete all as specified and directed., ditto item no 3 but in hard/dense soil., removing excavated material soil to a distance not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and directed, returning, filling in, including spreading, levelling watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed., material and labour for riddled earth for cushioning to under ground electric cable including spreading , levelling and hand punning complete all as directed. note - punned thickness shall only be measured & paid ., material and labour for road cutting/foot path and making good with pcc 1:3:6 type c-2 ( using 40 mm graded stone aggregate ) of 150 mm depth complete all as specified and directed., supply and laying un-reinforced precast concrete cable cover lv, type i, flat, size 250mm x 150mm x 40mm for under ground cable all as specified and directed., supply and laying gi tubes light grade, galvanized, 40 mm bore in repair ,laid in trenches or under floor or fixed with poles/walls for protection of electric cable all as directed, ditto item no -10 but 80 mm bore., material and labour for plain cement concrete (pcc) 1:3:6 type c2 using 40mm graded stone aggregate for making foundation of pole/stay assembly complete all as specified and directed., material and labour for plain cement concrete (pcc) 1:3:6 type c1 using 20mm graded stone aggregate for making copings of poles etc complete all as specified and directed. ., material and labour for earthing complete with galvanised steel earth plate eletrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5mtr below normal ground level, connected to the earth lead wire 4.0 mm dia (gi wire) size, by means of bolts, nuts, check buts and washers of galvanised iron, earth lead wire 4.0 mm dia protected by provision of gi medium grade pipe 15 mm bore including provision of 40 mm thick cover of rcc (1:2:4) 20mm graded stone aggregate re-inforced with xpm (weight not less than 4 kg per sqm) and frame of angle iron 40x40x3 mm with lugs 02 nos and with 6 mm dia ms bar handle made to shape, gi light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in hard/dense soil, returning filling in distance not exe 50 mtr and removal of surplas soil to plate no 3 of ssr 2009 part-i and connecting to earth test point all as specified or indicated including testing on completion complete all as specified and directed. , material and labour fo
Tender For providing of custom bid for services - addition & alteration construction of bio-chemistry lab at second floor. - dismantaling and disposal work; (a) first floor roof existing fibre sheet removal and disposal (16x5)feet , (b)second floor(bio chemistry) existing brick wall 9" th. dismantling and disposal , ( c) existing window removal (6x4'-6") , (d) existing floor dismantling and disposal , " 6.4.1 brick work with common burnt clay f.p.s (non modular) bricks of class designetion 7.5 in superstructure above plint level in all shapes and sizes in cement mortar1:6(1cement 6 coarse sand) " , plaster inside 12mm with 1: 6 ratio with fine sand , external plaster 15mm 1 :4 ratio 18mm cement plaster in two coats under layer 12 mm thick cement plaster1:5 ( 1cement :5 coarse sand ) and a top layer 6mm thick plaster , providing and laying reinforcement work , providing and laying rienforce cement concrete in retaining walls including attatched pilasters, colmns,piers,abutments pillars,posts,struts,buttresses,string,or lacing courses,parapets,coping,bed blocks,anchor blocks window sills ,fillllets,sunken floor etc.up to floor five level ,excluding the cost of centering ,shuttering ,reinforcement and finishing (5.2.2) , floor and roof protection work ;(4.20a.2.2) concrete of m15grade with minimum cement content 240kg/cum , 11.49.2 floor tiles; providing and laying full body vitrifiedtile in floor of minimum thickness 15mm with water absorption less than 0.06% and confirming to is:15622,of approved make, brand and manufacturer.laid on 20 mm thick cement mortar 1:4 . including grouting the joints with white cement /matching grout size600x600 , skirting , structural steel work welded in built up sections /framed work including cutting ,hoisting ,fixing in position and applying a priming coat of approved steel primer using structural steel .(250x125) , "red stone for slab providing sand stone slab for roofing and laying them in cement mortar1:4 ( 1 cement : 4 coarse sand ) over wooden karris or rcc battens or structural steel section (karries or battens or or structural steel. " , providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: , counter slab stone work , 8.2.2 . providing and fixing 18mm thick gang saw cut mirror polished, premoulded and prepolished,machine cut for kitchen platforms ,vanity counters,window sills ,facias and similar locations of required size approved shade ,colour and texture laid over20 mmthick base cement mortar, joint treated with white cement mixed matching pigment,including rubbing curing ,moulding and polishing of edges excluding hosting and transportation , counterslab stone skirting , providing edge moulding to 18 mm thick marble/granite stone counter,vanities etc. , p\ fteak wood frame ,providing wood work in frames of doors windows and other frames wrought framed and fixed in position with hold fast lugs or with dash fasterners of requireddia and length( hold fastlugs or dash fastenershall be paid for separetely. , p\f flush door , providing and fixing is markedflush door shutters confirming to is ;22029 part 1) non decorative type core of construction with frame of first class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters (9.21.1) 35 mm thick including isi markedsteel but hinges with necessary screws , fixing of aluminium window with all necessary at site available at site , providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : , finishing walls with acrylic smooth exterior
Tender For purchase of equipments ( s.no 1 to s.no 5 ) for civil department - purchase of equipment s, sand replacement test apparatus metal tray / base platesquare metal tray with a central hole (e.g., 300 mm 300mm with 100 mm hole). another common size: 450 mm square, 50 mm deep with 200 mm central hole for larger kitsseamless steel cylinder with no sharp edges. common size: 100 mm internal diameter, 127 175 mm length (varies by kit). mkpequipments.com +1wall thickness ~3 mm (industrial products) common size: 100 mm internal diameter, 127 175 mm length (varies by kit). mkpequipments.com +1 wall thickness ~3 mm (industrial products), core cutter aim 161 model core cutter: seamless steel tube (typically 100mm id, 130mm height, 3mm wall thickness). steel dolly: 25mm high, 100mm id, to prevent damage while driving. steel rammer: for driving the cutter. tools: spade, straight edge (knife), moisture containers. , slump cone apparatus 300mm ht, bottom dia 200mm,top dia 100mm with base plate andtamping rod material make : mild steel, jar test apparatus uniform stirring of up to 6 samples simultaneously. stirring rods should be adjusted individually during mixing digital display which should clearly indicate the speed of rotational variable speed 1-200rpm. heavy duty 1/20hp motor with gear train mounted on a mild steel housing. stainless steel stirring paddlers with adjustable height. paddles to be driven by electronically controller variable speed. locking collars or stirring rods permit adjustment height of paddle height. spacing of 6 (150mm) between stirring rods so as to permit use up to 1000ml beaker. the digital timer to be set to count down from 1 to 99 minutes. housing material: crc / ms sheet duly powder coated. power consumption : 220/230v ac supply 50hz single phase motor : 1/ 20hp motor good quality illumination : built in illuminator beaker : 6 nos 1000 ml beaker 1, compression testing machine 1000kn capacity capacity: 1000 kn type: hydraulic,floor-mounted accuracy: 1% of indicated load load application:smooth, uniform, controlled platens:hardened steel platens, suitable for concrete cubes/cylinders safety:overload protection, pressure relief valve, emergency stop, safety guard standards: is 516 / astm / iso compliant power supply: 415 v, 3-phase, 50 hz accessories: platens,spacers, pressure gauge, operating manual calibration: factory calibrated with certificate installation & training: included
Tender For bid to ras supply of br or em and office misc items d d - dwc high density polythlene pipe having corrugation on the outed wall plain surface ib tge ineer wall confirming to isi 14930 part i or ii for protection of ug cable of outer dia 50mm inner dia 38mm , portable air purifier machine make philips or equivalent , floor cleaning machine 1500w heavy duty isi marked , carpet size 6 feet x 142 feet heavy duty isi marked , thermosteel water bottle 1 ltr make milton borosil or equivalent , water dispenser mini magic pure 500watt make voltas blue star or equivalent , flushing cistern assembly make prayag shakti cera seiko or equivalent , pvc water storage tank 500 ltrs capacity triple layer make sintex or equivalent , pvc water storage tank 1000 ltrs capacity triple layer make sintex or equivalent , cp bib tap short body 15mm make prayag shakti cera seiko or equivalent , cp bib tap long body 15mm make prayag shakti cera seiko or equivalent , cp pillar tap 15mm make prayag shakti cera seiko or equivalent , cp angle cock 15mm make prayag shakti cera seiko or equivalent , cp health faucet 15mm make prayag shakti cera seiko or equivalent , urinal waste pipe make prayag shakti cera seiko or equivalent , cp urinal spindale 15mm make prayag shakti cera seiko or equivalent , glass shelf assembly make prayag shakti cera seiko or equivalent , teplon tap isi marked , ewc l pipe o ring make prayag shakti cera seiko or equivalent , cabinet mirror make prayag shakti cera seiko or equivalent , ewc l pipe washer make prayag shakti cera seiko or equivalent , ewc seat cover make prayag shakti cera seiko or equivalent , cp two way angle cock 15mm make prayag shakti cera seiko or equivalent ) /bid number : gem/2026/b/7517131 * /dated: 08-05-2026 & & / bid document 1 / 19
Tender For supply, installation, testing and commissioning of phase wire and street light and vairious electrical equipment needed for implementation of budget announcement 2025-26 - providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in, led street light fixture with minimum lumen output 5600 lm, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgear is to be paid extra )(d)wiring between components within switchgear and incoming / outgoing cable shall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap-offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be point to point (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)floor mounted panel sh