Get complete information related to latest Tranreceiver Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Tranreceiver Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Tranreceiver Tenders.
Tender For corrigendum : design, supply, installation, testing and commissioning of plc based terminal automation system comprising of tank truck loading system, tank farm management system, access control system, fire alarm system etc along with associated works at bitumen
Tender For supply, termination installation, testing and commissioning of ventilation system on roof of paint shop of lower parel workshop along with complete installation, frame work of suitable size with ms 50mmx 50 mmx 5mm, cabling, cable try work, wiring and protection system with 4 pole 20a mcb for each and mcb board along with 2.5 sqmm cable 4 core and 10 sqmm cable from panel to distribution board for main supply and power full exhaust system of length and height minimum 1 meter with width minimum 400 mm, diameter blades 900 mm, blades rotational speed -620 r/min or more. air flow 30,000 m?/h, noise level shall be less than 70 db, power shall be minimum 750 watt with the flap system and motor starter of 1 hp or as per suitable and confirming to s/iec 60947-4-1 or latest. all electrical works shall be carried out in accordance with the provision of indian electricity act 2003 and indian electricity rules 1956 amended to date and all the safety codes and procedures outlined in the safety codes shall be complied with general and safety requirement shall be governed by is 13947 (pt i) 1993 and is:8623/1993, amended to date. termination of all cables shall be done with bimetallic terminal connector suitable for 2.5 dia aluminium tubular busbar for 20a copper palm copper cu etp cw 0041a and aluminium barrel aluminium al 99.5 cable connector temperature resilience, corrosion resistance size: 2.5 sqmm confirming to is: 5561-1970 with maximum temperature rise of 90 degree celsius. material shall be confirmed to designation a6 of is: 617-1959. breaking resistance for barrel 85 n/m sq m and for palm 225 n/m sq m with stretching a5% for barrel must be for palm 2.5. type test certificate from nabl or any other govt agency lab report shall be attached along with the offer without which offer will be rejected. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply installation & commission of tss (terminal support system) & datacom equipment under crew management system for crew and guard lobby et,rkmp,bina.05 kiosk lobby terminal support system (tss) equipment with integrated breath analyzer, biometric and camera device according to cris specification no. no.2007/cris/ndls-hq/cms/project / rollout - ii / 0030 / pt -ii, dated 26.07.2024 or latest attached. (remark - 01 number to be delivered at crew and guard lobby et,03 number to be delivered at crew and guard lobby bpl, & 01 number to be delivered at crew and guard lobby bina.) [ warranty period:30 months after the date of delivery ] ]
Tender For tender for supply of operation and routine maintenance of water cooled chiller hvac system , 3x500tr i/c ahus and cooling tower , vrv system at various locations inside the terminal building and medical centre , various pumps and other installation of wtp and stp , ro , water coolers and split/tower/window ac units at various locations , water fountains inside the terminal building , ensuring serviceability/ satisfactory working condition of the systems i/c maintenance of records/logbook/ documents etc. on all days i/c saturday , sunday and holidays as per tender specifications , terms and conditions by supplying of following min. no. of man power- (a) supervisor (highly skilled) - 01 no. (i.e. 01 no. in general shift on 06 days in every week) (b) ac technician / mechanic (skilled) - 03 nos. (ie 01 no. round the clock on all days in every week for operation of chiller , reliever shall be provided on weekly off). (c) ac technician / mechanic (skilled) - 02 nos. (ie 02 no. in general shift on all days in every week for operation and routine maintenance of r.o. , water coolers and split/tower/window ac units at various locations , reliever shall be provided on weekly off). (d) asst. ac mechanic cum operator (semi skilled) - 09 nos. (i.e. 01 no. round the clock for operation of ahu , 01 no. round the clock for operation and maintenance of wtp , 01 no. round the clock for operation of stp on all days in every week , reliever shall be provided on weekly off). (e) asst. ac mechanic cum operator (semi skilled) - 01 no. (i.e. 01 no. in general shift for maintenance of stp , reliever shall be provided on weekly off). (f) helper (unskilled) - 03 nos. (i.e. 01 no. round the clock on all days in every week for hvac , reliever shall be provided on weekly off). (g) helper (unskilled) - 02 nos. (ie 02 no. in general shift on all days in every week for operation and routine maintenance of ro , water coolers and split/tower/window ac units at various locations , reliever shall be provided on weekly off). , operation and routine maintenance of vrv system at ats cum technical block and precision air conditioning system at new mssr building including maintenance of records/logbook/ documents etc. on all days including saturday , sunday and holidays as per tender specifications , terms and conditions by supplying of following minimum number of man power - (a) supervisor (highly skilled) - 01 nos. (i.e. 01 no. in general shift on 06 days in every week) (b) ac technician / mechanic (skilled) - 01 nos. (i.e. 01 no. in general shift on all days in every week for operation and routine maintenance of vrv system at ats cum technical block and pac system at new mssr building , reliever shall be provided on weekly off). (c) asst. ac mechanic cum operator (semi skilled) - 06 nos. (i.e. 01 no. round the clock for operation and routine maintenance of vrv system in ats block and 01 no. round the clock for operation and routine maintenance of pac system at new mssr building on all days in every week , reliever shall be provided on weekly off). , operation and routine maintenance of packaged air conditioning system at old mssr building including maintenance of records/logbook/ documents etc. on all days including saturday , sunday and holidays as per tender specifications , terms and conditions by supplying of following minimum number of man power - (a) asst. ac mechanic cum operator (semi skilled) - 03 nos. (i.e. 01 no. round the clock for operation and routine maintenance of packaged air conditioning system at old mssr building on all days in every week , reliever shall be provided on weekly off). , annual all inclusive comprehensive maintenance contract of central ac plant (hvac) for 3x500tr (make- mcquay) centrifugal chiller type comprising of 3 no. cooling tower (make- advance) and 1no cooling tower (make- bell) with make-up tank , associated pumps as condenser water pump - 03 no(40hp) , primary water pump - 03no (25hp) , secondary water pump 12 hr - 03 no.
Tender For material supply for the installation of 4 line hanging solar power fence at perambra estate - hanging solar power fence, p.p reel insulator-must be of virgin plstic material.polypropylene or equivalent with break down voltage of 15 kv(weight 25gm avh, length 4.6 cm avg), strain insulator- must of poly polypropylene plstic rated for 15 kv uv stabilized,(weight 40gm avg, length 7 cm avg), gi post 12 feet-2" gi pipe guage thickness, total 14.5 ft length modified to 12 feet length and cut and welding to 90 degree bend 2.5 feet length at top end and having diametrically opposite holes of size 6mm at end of bend pipe, intermediate post (t angle post)-6ft.,paited(25mmx25mmx3mm)having holes of size 6mm at required interval of fencing installation, supporting post- 10ft., gi-1",14 guage thickness,painted, stay (t angle)-2 ft., painted(25mmx25mmx3mm), 12 swg ht wire-12 guage,25mm dia high tensile with zinc coating for use as conducting wires for binding strain inulator, 14 swg binding wire- high quality zinc coating wire for binding reel insulators,tighing support post with corner post, 1.5 mm stainless steel wire rop 304 grade-1.5 mm stainless steel wire rop 304 grade, aluminium ferruel- aluminium ferrule inner dia 3mm, wire tightner- permanent wire tightner made of special aluminium alloy designed for kv,uv stabilized, earth rod- copper plated earth rod 14mm -3 ft. length, earthing compound- earthing compound 8kg, gate handle- gate handle and spring assembly. handle made of polyethyelene, leadout cable- lead out cable for fencie system double insulated gi cable inner core wire 2 sq.mm. hot dipped galvanlsed steel core, cable of with standing 15 kv should be provided to prevent bimetal salt formation at connections, single core 2.5 mm sq. cable- 2.5 mm2 single core copper cable for connecting the solar panel to the tuber battery through charge control unit with required terminal sockets, nut and bolt, washer, lightining diverter- 15 kv rod gap arrester,must be capable of diverting stray lightining and adjustable for spark raps adequate earthing to be provided, 100 watt solar panel- 100 watt/12 volt and above poly crystalline with 10 year warranty having iec/mnre certification, charge control unit- 20a, 12/24 v pwm charge controller unit of standard make suitable to control the charging of the tubular battery, energizer- energizer with 10 kv output safety standerds to be followed and bis 302-2-76 iec60335-2-76. switch high,medium and low power of settings, fence alarm system- fence alarm system conering area of 1.5 km, solar panel supporting stand with metal box painted ( for battery and energiser)- 18 guage thickness metal box (lockabe). gi sheet, painted should be capable of housing battery, charge controller and energizer and fixed with required clamps and nud and bolt on solar panel support stand made of gl pipe of 50mm daimeter and b class type with suitable arrangement for holding the panel, warning sign- polyethylene plastic with satuatory warning with signs, tubular battery 12v,100ah- 12v, 100 ah c10 rating with full 5 year replacement warranty(tower battery) for energising the energiser
Tender For supply of indication lamp red , led indicator 110v ac red , pilot lamp white complete , pilot lamp green complete , pilot lamp amber complete , pilot lamp red complete , led lamp , indication lamp green 110v , indication lamp green 230v , indication lamp red 230v , led indicator 24v dc green , apex system 22.5 mm dia pilot lamp green , apex system 22.5 mm dia pilot lamp yellow , transistor 2n 2647 for pcb , transistor 2n2906a for pcb , transistor 2n 3054 for pcb , diode 3z15a for pcb zener , diode 400v 35a , silicon diode 15a 50v , silicon diode 100a 50v , mosfet irf 840 , transistor 2n 2222 , rectifier silicon diode , push button red 1 no , push button green 1 no , push button yellow 1 no , push button with lamp green 1 no and 1 nc , oil tight push button start , variable potentiometer 1k for pcb , 3 heat switch 16a 500v for cooking range , thermistor relay , single phasing preventer vsp 3 , switch 6a 220 v dp , mcb ge 2 pole 6a 110 v ac , timer 0 to 30 min , contactor 30a , auxiliary contacts for 140a contactors , main contacts for 140a contactors , auxiliary contactor for 4 no 115v , contactor 44a , aux contactor 2no and 2 nc with 110v ac coil , overload relay 56 6 90a , relay overload 0.47 to 0.75a , overload relay2.2 to 3.1a , overload relay 4.5 to 6.5a , overload relay 17.4 to 24a , over current relay , olr 12 to 18a , fuse link 4a , fuse link 80a , hrc fuse link 200a , hrc fuse link 16a , hrc fuse fittings with fuse link 4a , fuse 80a , 100a hrc fuse link , hrc fuse link 10a , terminal board 10 sq mm , terminal board 2.5 sq mm , terminal board 6.0 sq mm //bid details 2 / 48
Tender For supply of superstructure of small living shelter of size 6 point10 m x 5 point 22 m x 4 point75 m height with 1 point 50 m enclosed verandah , ceramic tiles of size 600 mm x 600 mm for floor thickness between 9 to 10 mm , white cement conforming to , curtain arrangement drapery and rod made of 25 mm dia and 1600 mm long , distribution box 8 way spn comma 240 volts copper bus bar , mcb spn 240 volts 32 amps , mcb sp 6 to 32 amps , pvc tape 19mm wide 5m long , cable pvc insulated electric cables copper conductor of size 1 point 5 sqmm single core , cable pvc insulated electric cables copper conductor of size 2 point 5 sqmm single core , cable pvc insulated electric cables copper conductor of size 4 sqmm single core , pvc casing capping 1 inch medium grade snow white , pvc casing capping of size 3 oblique 4 inch medium grade snow white , switch piano 5 amp 230 volts flush type one way snow white , led tuble light fittings 15w 230v box type 4 feets , steel screw full thread with rawl plug plug of size 1 1 oblique 2 inch , pvc switch board 7 inch x 4 inch , pvc switch board 8 inch x 10 inch for main switch oblique db , pvc l bend and t junction joint for pvc casing and caping conforming , switch socket combination multipurpose 2 in 1 comma 15a 230v , switch socket combination snow white 5a 230v , service bracket 40mm dia gi tubing medium grade 1 point 5m long , service cable pvc insulated aluminium conductor comma 10 sqmm 2 core , ceiling rose three terminal snow white , led bulk head fitting with glass cover with led lamp 10 watts , pvc flexible wire copper conductor multi stranded , pvc flexible conduit pipe 15mm dia , pvc round oblique square block , exhaust fan 230 volts 300 mm sweep plastic body alongwith louvers and complete fittings , fire exitingusher of 1 kg capacity , monoblock pump set suitable for 230 v single phase system having capacity 2hp , distribution box 2 way with mcb spn 240 volts 10 amps , pvc flexible suction hose pipe 25mm dia heavy duty , non return valve nrv metal 25mm dia , earthing plate 600x600x6mm galvanised steel , ci earthing pit cover of size 300x300x6mm with angle iron isa 20x20x3mm thick ms frame , funnel fitted with 20mm dia gi pipe 1 point 5m long , gi wire 4mm diameter for earthing , charcoal , salt normal , air terminal single pointed aluminium rod 12mm dia and 300mm long , testing point terminal block make of gun metal and phosphorus bronzesize 75x75x25mm , aluminium strips 25x3mm , galvanised iron strip 32x6mm , earthing plate 600x600x6mm galvanised steel suitable for gi strip fittings , insulating pvc block 75x75x30 mm with insulating clamp nut and bolt , individual standalone plastic body smoke alarm , individual standalone plastic body heat alarm , fire ball extinguisher 1 point 3 kg with suitable provision for wall mounting , double sleeping bunk with matress complete , steel bed side locker of size 1000mm x 1520mm x 450mm complete , study chair of size length 56 cm comma height 82 cm and width 56 cmcomma lacquered finish , study table of size 900mm x 600mm x 760mm wih 18 mm thick prelaminated particle complete , looking mirror of size 18 inch x 4 inch fixed with 4 mm thick ply , water dispenser of 230 v 500 watts without refrigerator capacity of 5 lts oblique hour , protable indoor type high quality kero heater metal body ignites type min 8 hrs and above with capacity 4 ltrs , plastic dustbin of capacity 40 ltrs //bid details 2 / 40
Tender For corrigendum : supply and commissioning of igbt based 3-phase drive propulsion equipment with physical medium i.e. esd/ emd/ ofg for multi - functional vehicle bus (mvb) as per iec61375, terminal bracket, bus bar link and cu braid required for connection between main transformer and traction converter, auxiliary converter, interfacing connectors, cables and cable loom required for connection from vcu1/2 to sb1/2 panel. as per spec. no. i) rdso/2008/ el/spec/0071, rev. 5 for igbt based 3-phase drive propulsion equipment, ii) clw/es/3/0458 alt. e for cont rol cables, iii) clw/es/3/0459 alt. c for screened cable, iv) clw/es/3/0124 alt. p. in addition to above description, the propulsion system should also comply requirement mentioned in "schedule of requirement" (sor) doc no. plw/el/propulsion system/sor/002 rev. 02 with annexure a, b , c , d & e [sept-25]., copy attached with tender documents. annual maintenance for three (03) years will be as per comprehensive annual maintenance specification no. clw/amc/c-d&d/01 issued in march 2016. [ warranty period: 72 months after the date of delivery ] ]
Tender For purchase of ece department lab electronics equipments - equipments for ece, dual output regulated dc variable power supplyinput voltage : 230v/50hz acoutput voltage :(0-30)v dcoutput current :(0-2)a dcprotection circuit : over voltage, over current, and short-circuit protectionhigh efficiency : greater than 85%low ripple and noise : less than 50 mvdigital display, function (signal) generatorspecs:frequency range : 0.1hz to 5mhzdisplay :4 to 6 digit led displayoutput waveforms : sine, triangle, square, pulse, rampamplitude :0-20 vpprise time :100 nsdistortion : 1% within specified frequency rangepower supply : 230v ac 10% , 50-60 hzoutput amplifier protection : short circuit and 15voverload protectiondc offset: 0 to 10 v adjustableattenuation: 0 to -60 db, decade resistance box range : 1 to 1m rotary switch selection with 6 dialssteps : 1 , 10 , 100 , 1k , 10 k , 1m accuracy : 1%, decade capacitance box range : 100 pf to 100 frotary switch selection with 6 dialsmaximum voltage : 350vaccuracy : 1%, decade inductance box range : 10 h to 10 hrotary switch selection with 6 dialslow-loss inductorsaccuracy : 1%, sim reader trainer kitpower supply :operates on 230v ac 10%, 50hz mains supplybuilt-in regulated smps power supplyoperating dc supply : 5v/12v with overload and short-circuit protectionsim card interface :supports gsm sim cards compatible with 2g / 3g / 4g / 5g networkssim card read/write interfacesupports sim card initialization, authentication and communication functionscompatible with standard 6-pin / 8-pin sim card socketscommunication interface :usb 2.0 interface for pc communicationrs-232 serial communication interfaceuart communication facility for embedded system interfacingsim operating parameters :selectable sim clock frequencies3.579 mhz7.159 mhz14.318 mhzsim supply voltage selection facilitysim reset and activation controlsupported protocols and standards :gsm etsi 07.07 and etsi 07.05 at command supportiso/iec 7816 smart card communication supportsim communication command monitoring facilityhardware features :on-board sim card socketled indication for :power statussim detectionreset activityuser manualutility software cd / downloadable software packagedata transmission/receptionbuilt-in keypad for standalone operation.lcd display module (128 64) for menu and status display.on-board microcontroller-based control section.software support:at command execution and monitoring software.sim manager utility software.data logging and communication terminal utility.pc-based gui software for sim data communication experiments.trainer features:fault simulation facility for troubleshooting experiments.simulation of faults such as:sim not detectedclock failurevcc failurereset failuremultiple on-board test points for signal observation.test points for:sim rstsim_clksim iovccuart tx/rxsuitable for cro/dso signal monitoring.glass epoxy pcb with educational block diagram layout.compact tabletop enclosed cabinet design.construction:front panel with printed block diagram.banana test points and patching facility.standard accessories:gsm sim trainer unit.usb communication cable.rs-232 communication cable.power cord., microwave test bench with reflex klystron oscillatormicrowave source :relex klystron tube with klystron mountoperating frequency in x-band (8.2ghz to 12.4ghz)electronic tuning through repeller voltage controlsuitable for cw microwave generationklystron powersupply:regulated klystron power supply unitbuilt-in modulation facilityoverload and short circuit protectionoperates on 230v ac 10%, 50hz mains supplywaveguide components:isolator variable attenuatorfrequency meterslotted line section with tunable probecrystal detector mountmatched loadmovable short / terminationwaveguide stands and accessoriesmeasurement unit:solid state vswr meter with high sensitivityswr measurement facilitysuitable for detector output monitoringtechnical specification :frequency range : 8.2 ghz to 12.4 ghzwaveguide types : wr-90detector type : crys
Tender For s&t work in connection with provision of e-1 communication channel through optical fiber cable from rcc to remote terminal unit (rtu) at 09 nos. of switching posts (nob/ssp, bzc/ssp, simr/ssp, sona/sp, psf/ssp, kyb/ssp, rngr/ssp, mtip/ssp & msae/sp) over adra division for installation of high speed tcp/ip based scada system.