Web Analytics Made Easy - StatCounter

Transcriptome Analysis Tenders

Get complete information related to latest Transcriptome Analysis Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Transcriptome Analysis Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Transcriptome Analysis Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :43270629 Due date: 12 Jan, 202612 Jan, 2026 NA
Tender For supply of title - aluminium extension ladder, 11m aluminium ladder extension wall support ladder 24/40 asspecification given below aluminum alloy wall support extension ladder proved with top hand rallis and platform steps made of 26" 3 mm round corrugated flutted pipe main extrusion made up of aluminum alloy section 66*32*4mm thickness of he 30 grade t6 tempe hindalco make closed height 24 feet additional msguide pipe fixed insideheight 40 feet additional msguide pipe fixed inside of the ladder at 1 mir internal for stability of ladder arms., aluminium tower ladder of tiltable (inclined) tower ladder with bucket type having reach height of 31-40 (detailed descripbon/specification as per product # 1of gem contract no. gemc-511687717666536 dt. 15/12/2024) make-alied, alco, sumer, s.j. ladders, aluminium ladder self support & feet, anti skidding make-caw or superior , supply of heavy duty manual drum trolley suitable for handling standard 200-250 liter drums, capacity 250 kg. made of ms with powder-coated finish, suitable for titing, lifting and rotating operations, provided with 3 puirubber wheels for easy movement, equipped with mechanical drum holding damp, rotatable up to 3607, lifting height approx. 300-500 mm, manual handle operated, robust construction, without sharp edges , supply of heavy duty long life hydraulic operated manual stacker as per description: capacity 2000 kg. overall length 17:50 mm, fork arm length 1150 millimeter, overall fork width 650 mm (adjustable), lowered fork height 85 mm, mast height (close height) 2000 mm, tuming radius 1450 mm, lifting speed 14 mm per stroke, tandem pu rollers (80-70 mm), pump made of cast steel with powder-coated finish, construction ms (6 mm), service weight 234 kg, controllable lowering speed, and without sharp edges, supply of heavy duty aluminium, telescopic ladder, 14 steps (approx.) maximum extended height 18 ft (approx.), made of aluminium alloy with 1.5 mm thickness (approx.) foldable design, overall dimensions 109.27 48.57 8.8 cm (all approx.), weight 13.5 kg (approx), load capacity 150 kg (approx.), supply of aluminium platform ladder, height 5 ft (approx.), 4 steps (approx.), load capacity 100 kg (approx.), foldable design with top platform, made of aluminium, robust construction, without sharp edges, light weight moped trolly, push trolley b.g. with umbrella complete for p.way track inspection as per rdso specification no. tm/sm/lw/pt dated 03.02.2014, push trolley b.g. with umbrella complete for p.way track inspection as per rdso specification no. tm/sm/lw/pt dated 03.02.2014, digital cooking oil tester for total polar compounds (tpc meter). sample to be approved by competent authority before supply., poly proplene rope 18mm dia, unbranded pvc flexible waste pipe length 1200 mm brand: na (detailed description/ specification as per product # 1 of gem contract no. gemc-51168776088276 đi. 05/03/2025), upvc column pipe 50 mm dia type "heavy" pressure 27 kg/cm2, item code (colhvy200c) & equivalent. make: kisan kml, ashirwad kasta, retro reflective sticker golden yellow colour size width 4 feet, thick 0.40 to 0.45 mm.for slr brand mor avery dennison or orajet or similar, ss. self drilling screw 19x6 mm,, as per din and isi standard, bib cock as per cat. no. 29037 fusion range of m/s jaquar or mso-2080 of m/s marc, or fno-011 of m/s eauset or hr03 of essess or se-00202 of m/s agmeco, as approved by cde/rcf, subject to compliance of firm with clause 3 to clause 7 of section a of rdso/2008/cg-05, chain pulley block-2 ton chain length 10msingle fall isi marked, chain pulley, material- casting and forging, max lifting height: 3m - 10m, chain length: 3m-10m, weight: 20 kg (for 3m chain). make: ferreterro model number: ll020, indef 2000 kg (2 ton) & bajaj, retro reflective stop disc 600 mm dia red disc from minimum 20 swg gi sheet with a vertical stiffening "v' or 'u' bend in the middle having red reflector buttons/luminous stripes facing the road traffic. the dis

CTN :43185676 Due date: 05 Jan, 202605 Jan, 2026 NA
Tender For purchase of various apparatus/instruments required for department of chemistry, chaudhary ranbir singh university, jind - stirrer- the stirrer should be made up of ceramic coated aluminium alloy top with digital speed and temperature control. the stirring speed should be 50-1500 rpm or better. the stirrer should be operational up to a temperature range of 300oc with an accuracy of 1.0oc and ip 42 protection class. the input power should be 600 w or above. the stirrer should be supplied with hemispheric bowl (100 ml= 1 no; 250 ml= 1 no) to replace oil baths and mantles in order to perform clean and safe analysis with round bottom flasks.warranty must be one year., electronic balance- the electronic balance should have a maximum weighing capacity of 200 g or more with a resolution and repeatability of 0.1 mg, and a response time of 5 sec or better. the system should have automatic internal calibration with touch screen display. the system should have internal database capacity of 2500 or more with multiuser password protection feature. warranty must be one year., vaccum pump - the pump should be operational at a maximum power of 65 w or more with a max. vaccum of 99 mbar or more. the pump should be fitted withvacuum and filter cartridge., hot air oven- the inner chamber should be made of stainlesssteel and the outer chamber should be m.s powdercoated. the maximum capacity of the oven shouldbe 100 ml or more. the operational temperatureshould be between ambient to 250oc or more witha temperature accuracy of 1o c. pid based digitaltemperature control., double distillation unit- the unit should be pyrogen free with a distillation water output capacity of 1.5 l/h. the minimum cooling water requirement should be 1lt/min. auto-power cut facility in case of halted supply of water., circulating oil bath- the oil bath should be made up of stainless steel with 4 digit 7 segment led display for temperature and time. the bath should have s.s perforated tray for holding flasks. the bath should have a capacity to accommodate flask of 1l. the working temperature range should be +5 to 240oc (0.1oc increment) with a temperature stability of 1oc, water bath- the water bath should have a capacity of 20 l within built water level sensor. the bath should be made up of stainless steel and supplied with 8 concentric rings. the bath should have digital temperature control with pt100 sensor. the system should have stirring capability with ptfe magnetic bars., ph/ condutivity meter - operational between a ph range of -2 to 16.00 with a resolution of 0.01 ph and an accuracy of 0.02 ph. 5 points calibration. the ec range shouldbe in between 0.00 to 29.99 s/cm, uv cabinet- operational at two uv wavelengths (254 and 365 nm). the cabinet should also be equipped with one visible light. the external body should be coated with ms powder/epoxy., flame photometer- application: the flame photometer is used for qualitative and quantitative determination of several cations, especially for metals that are easily excited to higher energy levels at flametemperature. these metals include na+, k+, ca2+, ba2+ and li2+.specification requirementmeasuring range na+: 0 to 99.9 ppm k+:0 to 99.9 ppm ca 2+ :0-99.9 ppmli 2+: 0 to 99.99 ppmsensitivity na+= 0.1 ppmk+ = 0.1 ppmspecificity less than 0.5% interference when concentrations are equal to test sample concentrationsgas control-adjustable with knobsignition system-auto ignition systemflame failure-auto detectiongas cut off-automaticreproducibility-less than 1% coefficient of variation for 20 consecutive samplesusing 10 ppm na set as maximum standardlinearity-less than 1%display led, 12.5 mm (1/2")fuel supply-high-grade propane/butane mixture regulated at approximately30 psiair supply-6 l/min at 12 psi; oil and moisture freerecorder-output 0.05 to 5 v (switchable)operating manuals, service manuals, other manuals should provide user, technical and maintenance manuals in english language list of equipment and procedures required

State Government

CTN :42756383 Due date: 29 Dec, 202529 Dec, 2025 NA
Tender For corrigendum : purchase of biomechanical equipments - nord board, it should be portable and should have 2 load cell sensors per unit with easy to attach hooks pivoting 360 degrees joint improving sensor accuracy it should have knee position indicator for replication of test position in each time. should have sample rate per sensor: upto 400hz, capacity per sensor: 100 kg/980-1000n safe over load per sensor: 150kg/1500n, max over load per sensor: 200kg/ 2000n, resolution: 1n and sensitivity: 22.0+/-mv/v. should have rechargeable battery & battery life should be100 active hours approx. should have working temperature range 5-40 c. (all weather proof) latest upgradable software should have both wired & wireless connectivity connectivity through usb (wired) bluetooth low energy (ble) for ipad & iphone i.e. (wireless connectivity) should provide 4 years warranty on hardware,should be provided with latest upgradable software and free software updates. should have software available in mobile & laptop (desktop) application with cloud analytics platform applications. should have ability to collect data both local i.e. laptop and on ios devices. local software:- for data collection & data analysis locally. cloud software:- for athlete data management and analysis. local (desktop /laptop) software should be compatible with windows 10 desktop applicationios 13 or later application (ipad & iphone). should have ability to collect data of over 10000 athletes or more to choose with simple name search / grouping them. cloud analytics platform for analysis. software (application) must give real time feedback of testing. license must be valid for 4years. cloud software: - should automatically sync all data collected on local mobile and laptop application when connected to internet.o should have a dashboard to see overview of organization s athletes data and different tiles(data indicators) to see athletes within and outside threshold zones. report section:- should have port section to able to compare different groups/athletes on longitudinal data. should have ability to compare same athlete s data over the period. athletes profile:- should have functionality to enter anthropometry (i.e. upper body & lower body measurement). athletes profile should be auto sync to local application and flexibility to move across different groups or teams with in organization and functionality to pick any athlete from large pool (1000 or more athlete). should be able to setup different access to different people i.e. to physiotherapist, sports scientist and s&c trainer within the organization to secure data access.api integration:- should have open-source api code for integration into athlete management system to integrate in ams system. should have software license valid for 4years. wi-fi tablet 64gb, space grey-1year warranty (as provided by oem) - service by customer service of oem only.hsn:8471.training for installation and demonstration shall be provided at olympian balbir singh senior international hockey stadium, sector- 63, mohali, punjab., electromyography (open), the system should be supplied with minimum 16 high speed wireless emg channel with built in imu sensor. should have analog+ digital base station should have analogy output option to facilitate integration with third party hardware and software sensor should have fixed inter sensor delay of 0.5 milliseconds or less sensors should have fixed spacing between electrodes preferably less than 15 mm to avoid motion artifacts and cross-talk sensor contacts should be made up of a metal for better contact and better-quality signal should be supplied with a charging/transmitting station that communicates with sensors to get information on their charging, recording and signal strength sensors, sensor skin interface, cable, power adapter and accessories sensors facilitate emg and imu measurements emg data analysis software for stand-alone usage with live recording of at least

Central Government And Public Sector

CTN :43268201 Due date: 30 Dec, 202530 Dec, 2025 6.50 Lacs
Tender For providing of selection of laboratories for testing of products/material - drinking water; buyer to use custom filter to input technical specification of the product/material so that service provider may provide price offering accordingly; sample; chemical

State Government

CTN :43241409 Due date: 12 Jan, 202612 Jan, 2026 7.35 Lacs
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; tube bending services from supplied straight tubes as per opgc provided bend sample / approved drawing; service provider

Central Government/Public Sector

CTN :43225683 Due date: 07 Jan, 202607 Jan, 2026 3.48 Lacs
Tender For providing of selection of laboratories for testing of products/material - camel milk; buyer to use custom filter to input technical specification of the product/material so that service provider may provide price offering accordingly; sample; lcms(q-tof), jram & ..

State Government

CTN :43173406 Due date: 12 Jan, 202612 Jan, 2026 7.35 Lacs
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - manufacturing unit; tube bending services from supplied straight tubes as per opgc provided bend sample / approved drawing; service provider

Corporations And Associations And Others

CTN :43158958 Due date: 02 Jan, 202602 Jan, 2026 44.2 Thousand
Tender For providing of selection of laboratories for testing of products/material - drinking water; buyer to use custom filter to input technical specification of the product/material so that service provider may provide price offering accordingly; sample; complete analysi..

Central Government And Public Sector

CTN :43109447 Due date: 31 Dec, 202531 Dec, 2025 NA
Tender For supply of integrated transcriptome analysis of human genome -for detail specification check boq file a , integrated transcriptome analysis of human genome -for detail specification check boq file b , integrated transcriptome analysis of human genome -for detail specification check boq file c , integrated transcriptome analysis of human genome -for detail specification check boq file d , integrated transcriptome analysis of human genome -for detail specification check boq file e
 Loading, Please wait...

Connect us via What's Up