Web Analytics Made Easy - StatCounter

Transformer Foundation Tenders

Get complete information related to latest Transformer Foundation Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Transformer Foundation Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Transformer Foundation Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :41868691 Due date: 25 Sep, 202525 Sep, 2025 48.10 Lacs
Tender For construction of 1 no. 20/25 mva transformer foundation bay and 1.0 no. bus coupler bay at 132 kv gss deeg

CTN :41868708 Due date: 25 Sep, 202525 Sep, 2025 13.68 Lacs
Tender For construction of foundation for 40/50 mva transformer and its bay at 220 kv gss khushkhera

CTN :41868711 Due date: 25 Sep, 202525 Sep, 2025 40.60 Lacs
Tender For construction of 1 no. 20/25 mva transformer foundation bay at 132 kv gss kaman

CTN :41868714 Due date: 25 Sep, 202525 Sep, 2025 13.99 Lacs
Tender For construction of foundation for 20/25 mva 3rd transformer and its bay at 132 kv gss tizara

CTN :41868715 Due date: 25 Sep, 202525 Sep, 2025 14.15 Lacs
Tender For construction of foundation for 20/25 mva 3rd transformer and its bay at 132 kv gss shahjahanpur

CTN :41858096 Due date: 17 Sep, 202517 Sep, 2025 45.7 Thousand
Tender For shifting of 100 mva transformer main tank from foundation to yard

CTN :41868713 Due date: 25 Sep, 202525 Sep, 2025 14.17 Lacs
Tender For construction of foundation for 40/50 mva transformer and its bay at 220 kv gss kishangarh bas

State Government

CTN :41844068 Due date: 10 Oct, 202510 Oct, 2025 NA
Tender For pcc of open area in 220kv switchyard in front of rtss bimlagarh feeder (adjacent to 220kv transformer-ii foundation) at 220/33kv grid substation, bonai under eht (o&m) division, rourkela

CTN :41841946 Due date: 29 Sep, 202529 Sep, 2025 8.38 Lacs
Tender For construction of foundation for transformer at redwani bala, installation of htlt distribution network with link set padder mohalla and magrey mohalla at cr pora and installation of 100 kv transformerwire at hajam mohallah bugam

Central Government/Public Sector

CTN :41596971 Due date: 27 Sep, 202527 Sep, 2025 42.58 Lacs
Tender For corrigendum : provision of external electric supply for 661 sailors inliving accommodation at visakhapatnam - supply, installation, testing and commissioning of outdoor type step down transformer 1000 kva 11kv/433v dyn11 oil filled (onan) distribution transformer double copper wound with radiator wall with conservator tank & porcelain bushing for ht, lt with off circuit tap changer, marshalling box all as per is 1180 (part-1) : 2014, bee certified, energy efficiency level ii (as per latest ammendment no 4) complete as directed., a) off circuit tap changer (octc), tapping range +5% to -10% in a steps of 2.5% per step (7 positions)b) temp. rise shall be 40/45 deg. c for oil/winding resp. over an ambient of 50deg.c tempc) insulation class: ad) losses ( subject to is 1180 efficiency level 2/ star 2 as per latest amendment 4) max. total loss @ 50% loading: 2620 w and max. total loss at 100% loading: 7000 w.e) % impedance (%z) shall be 5.00% (subject to is tol.)f) rating & diagram (r&d) plate (fitted on transformer)g) oil temp. indicator (oti) with alarm and trip contacth) winding temp. indicator (wti) with alarm and trip contactj) rated temp class of transformer compartment k10 upto 1000kvak) lifting lugs/ hooks for transformer.l) oil filling inlet pipe with plug.m) air release valve and drain out pipe with plug.n) conservator tank with level guage.o) silica gel breatherp) first oil fill up to recommended level by manufacturer with new oil as per is 335.q) cable terminal boxes with bushes on both ht and lt sides.r) hv winding: delta & lv winding: star.note: civil work for the construction of foundation including necessary earthwork etc is deemed to be included in quoted rates of the item., supply and fixing main lt panel cpri approved made out of crca sheet 3.15 mm thick outdoor pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size, weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per al bus bar rated with insulators suitable for three phase and four wire lt ac, 50 hz 415 v 2000 a capacity complete with powder coating, necessary internal electric connection as required and provision of the following : (main lt panel)., incoming:air circuit breaker 1600 amps, 50 ka, mdo type, 4 pole, micro processor release, with adjustable type overload protection, short circuit protection, with necessary cts, meters and cable boxes. - 1 no.outgoing:a) mccb 250 amps, 25 ka, 4 pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection - 07 no (bldg vtpn 02 nos, bldg panels 04 nos + spare)b) mccb 140 amps, 25 ka, 4 pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection - 01 no (dg amf panel)c) mccb 160 amps, 25 ka, 4 pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection - 01 no (ff panel)d) mccb 100 amps, 25 ka, 4 pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection - 01 no (apfc panel)e) intelligent panel meter to measure voltage, current, frequency, power factor, kwh etc with all connected cts.f) led indicating lamps with colour red, yellow, blue of 03 sets.note: civil work for the construction of foundation including necessary earthwork etc is deemed to be included in quoted rates of the item., supply & fixing of perforated gi cable tray of size 150 mm width x 50mm depth x 1.6mm thickness with perforations not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with gi suspenders including bolts & n
 Loading, Please wait...

Connect us via What's Up