Web Analytics Made Easy - StatCounter

Transformer Breather Tenders

Get complete information related to latest Transformer Breather Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Transformer Breather Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Transformer Breather Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45314170 Due date: 01 Jun, 202601 Jun, 2026 1.17 Crore
Tender For providing erd for 4 no lifts, extension expansion of expansion of electric sub station and air conditioner for conference hall in the campus of mini sectt., distt sonipat.(pdg. 500 kva transformer, 400 kva diesel generator set and cabling work only). recall

CTN :45197592 Due date: 28 May, 202628 May, 2026 NA
Tender For corrigendum : tender for supply of terminal block 4 sqmm screw connector type , fuse , 6.3a , 5 x 20 , terminal block 4 sqmm , control relay glass type 2c/ o 110vac with base , mcb 2 pole 10 a c curve , pilot lamp white , indication lamp 110v ac 22mm diameter (red) , indication lamp 110v ac 22mm diameter (amber) , control cable 8 x 1.5 sqmm pvc insulated 80 mtr , limit switch , direct drive motor , controller transformer 1p 300va 380// 110v , stainless steel ss304 encl 500x500x210(control panel) , proximity sensor , luna light skewing system steel structure assembly , power cable 3 x 2.5 sqmm pvc insulated 15 mtr , joystick controller 2 direction 22mm diameter , electric motor direct drive controller , main switch disconnector 3 pole 25a , stainless steel ss304 encl 175x150x150(operating station)

CTN :45277957 Due date: 10 Jun, 202610 Jun, 2026 NA
Tender For rate contract for supply of materials for 33kv lines and 33 by 11kv recieving stationsfor the year 2026-27. - 33 kv & 11 kv cable kits indoor/outdoor (make hot set or any other reputed make conforming to relevant is specifications) a) cable kits 33 kv single core heat shrinkable indoor 630 mm2, b) cable kits 33 kv single core heat shrinkable indoor 300 mm2, c) cable kits 33 kv single core heat shrinkable outdoor 630 mm2, d) cable kits 33 kv single core heat shrinkable outdoor 300 mm2, e) cable kits 11 kv single core heat shrinkable indoor 630 mm2, f) cable kits 11 kv single core heat shrinkable outdoor 630 mm2, g) cable kits 11 kv 3 core heat shrinkable indoor 400 mm2, h) cable kits 11 kv 3 core heat shrinkable indoor 300 mm2, i) cable kits 11 kv 3 core heat shrinkable indoor 240 mm2, j) cable kits 11 kv 3 core heat shrinkable indoor 185 mm2, k) cable kits 11 kv 3 core heat shrinkable indoor 120 mm2, l) cable kits 11 kv 3 core heat shrinkable outdoor 400 mm2, m) cable kits 11 kv 3 core heat shrinkable outdoor 300 mm2, n) cable kits 11 kv 3 core heat shrinkable outdoor 240 mm2, o) cable kits 11 kv 3 core heat shrinkable outdoor 185 mm2, p) cable kits 11 kv 3 core heat shrinkable outdoor 120 mm2, q) cable kits 11 kv 3 core (straight through joint), heat shrinkable 120 mm2, r) cable kits 11 kv 3 core (straight through joint), heat shrinkable 185 mm2, s) cable kits 11 kv 3 core (straight through joint), heat shrinkable 240 mm2, t) cable kits 11 kv 3 core (straight through joint), heat shrinkable 300 mm2, u) cable kits 11 kv 3 core (straight through joint), heat shrinkable 400 mm2, v) cable kits 11 kv single core (straight through joint), heat shrinkable 630 mm2, w) cable kits 33 kv single core (straight through joint), heat shrinkable 630 mm2, 11 kv cts of different ratios, make mei/ bicco lawrie / crompton greaves / bhel/ er/ ssg/ alstorm for 11 kv ocb/ vcb panelsi) 800/400/5-5, ii) 750/375/5-5, iii) 600/300/5-5, iv) 400/200/5-5, v) 300/150/5-5, vi) 150/75/5-5, spares for power transformersa) breather for 6.3 mva 33/11 kv transformer (2 kg), b) breather for 1.6 mva 33/11 kv transformer (kg), c) breather for 3.15 mva 33/11 kv transformer (kg), d) breather for 10 mva 33/11 kv transformer (3 kg), e) breather for 5 mva 33/11 kv transformer (2 kg), f) 20 mm lt bush rod for 33/11 kv transformer, g) 12 mm lt bush rod for 33/11 kv transformer, h) 20 mm copper bush rod assembly for 33/11 kv, 10 mva power transformer with oil seal, i) 12 mm copper bush rod assembly for 33/11 kv, 6.3 mva power transformer with oil seal, j) silica gel, k) oil seal for 33/11 kv power transformer, l) adaptor for bush rod extension for 33/11 kv power transformers, relays a) numerical relay (24-50 v) 3 o/c and 1 e/f relay of different make .(scada compatible), b) numerical relay (24-50 v) 3 o/c and 1 e/f relay of different make.(non-scada compatible), c) master trip relay 24-50 v ,of different make, 33 kv & 11 kv insulators make iec, bhel, rastriya, top line, tcpl or any other reputed make conforming to relevant is specification a) 33 kv pin insulator with pins (porcelain type), b) 33kv pin insulators for panther conductor with pins (polymer type), c) 33kv pin insulators for wolf conductor with pins (polymer type), d) 33kv pin insulators for dog conductor with pins (polymer type), e) 33 kv g.i. pins, f) 11 kv pin insulator (polymer type) with pins, g) 11 kv pin insulator (porcelain type) with pins, h) 11 kv g.i. pins, i) 11 kv disc insulator (b & s type) 70 kn (porcelain type), i) 11 kv disc insulator (b & s type) 120 kn (porcelain type), j) 33kv disc insulators (polymer type), k) 33 kv post insulator, l) 22 kv post insulator, m) 11 kv post insulator, n) drive insulator of sorts, o) shackle insulator, p) 11 kv guy insulator, q) 33 kv guy insulator, 33 kv tension fittings for acsr dog conductor, b&s 3 u-bolts type, 33 kv tension fittings for acsr wolf conductor, b&s 4 u-bolts type, 33 kv tension fittings for acsr panther conductor, b&s

CTN :45271786 Due date: 10 Jun, 202610 Jun, 2026 NA
Tender For rate contract for supply of material required for repair/maintenance /restoration of 33kv lines and 33/11kv receiving stations in respect of std-iv kalakote, for the year 2026-27 or till next contract. - 33 kv & 11 kv cable kits indoor/outdoor (make hot set or any other reputed make conforming to relevant is specifications) a) cable kits 33 kv single core heat shrinkable indoor 630 mm2, b) cable kits 33 kv single core heat shrinkable indoor 300 mm2, c) cable kits 33 kv single core heat shrinkable outdoor 630 mm2, d) cable kits 33 kv single core heat shrinkable outdoor 300 mm2, e) cable kits 11 kv single core heat shrinkable indoor 630 mm2, f) cable kits 11 kv single core heat shrinkable outdoor 630 mm2, g) cable kits 11 kv 3 core heat shrinkable indoor 400 mm2, h) cable kits 11 kv 3 core heat shrinkable indoor 300 mm2, i) cable kits 11 kv 3 core heat shrinkable indoor 240 mm2, j) cable kits 11 kv 3 core heat shrinkable indoor 185 mm2, k) cable kits 11 kv 3 core heat shrinkable indoor 120 mm2, l) cable kits 11 kv 3 core heat shrinkable outdoor 400 mm2, m) cable kits 11 kv 3 core heat shrinkable outdoor 300 mm2, n) cable kits 11 kv 3 core heat shrinkable outdoor 240 mm2, o) cable kits 11 kv 3 core heat shrinkable outdoor 185 mm2, p) cable kits 11 kv 3 core heat shrinkable outdoor 120 mm2, q) cable kits 11 kv 3 core (straight through joint), heat shrinkable 120 mm2, r) cable kits 11 kv 3 core (straight through joint), heat shrinkable 185 mm2, s) cable kits 11 kv 3 core (straight through joint), heat shrinkable 240 mm2, t) cable kits 11 kv 3 core (straight through joint), heat shrinkable 300 mm2, u) cable kits 11 kv 3 core (straight through joint), heat shrinkable 400 mm2, v) cable kits 11 kv single core (straight through joint), heat shrinkable 630 mm2, w) cable kits 33 kv single core (straight through joint), heat shrinkable 630 mm2, 11 kv cts of different ratios, make mei/ bicco lawrie / crompton greaves / bhel/ er/ ssg/ alstorm for 11 kv ocb/ vcb panelsi) 800/400/5-5, ii) 750/375/5-5, iii) 600/300/5-5, iv) 400/200/5-5, v) 300/150/5-5, vi) 150/75/5-5, spares for power transformersa) breather for 6.3 mva 33/11 kv transformer (2 kg), b) breather for 1.6 mva 33/11 kv transformer (kg), c) breather for 3.15 mva 33/11 kv transformer (kg), d) breather for 10 mva 33/11 kv transformer (3 kg), e) breather for 5 mva 33/11 kv transformer (2 kg), f) 20 mm lt bush rod for 33/11 kv transformer, g) 12 mm lt bush rod for 33/11 kv transformer, h) 20 mm copper bush rod assembly for 33/11 kv, 10 mva power transformer with oil seal, i) 12 mm copper bush rod assembly for 33/11 kv, 6.3 mva power transformer with oil seal, j) silica gel, k) oil seal for 33/11 kv power transformer, l) adaptor for bush rod extension for 33/11 kv power transformers, relays a) numerical relay (24-50 v) 3 o/c and 1 e/f relay of different make .(scada compatible), b) numerical relay (24-50 v) 3 o/c and 1 e/f relay of different make.(non-scada compatible), c) master trip relay 24-50 v ,of different make, 33 kv & 11 kv insulators make iec, bhel, rastriya, top line, tcpl or any other reputed make conforming to relevant is specification a) 33 kv pin insulator with pins (porcelain type), b) 33kv pin insulators for panther conductor with pins (polymer type), c) 33kv pin insulators for wolf conductor with pins (polymer type), d) 33kv pin insulators for dog conductor with pins (polymer type), e) 33 kv g.i. pins, f) 11 kv pin insulator (polymer type) with pins, g) 11 kv pin insulator (porcelain type) with pins, h) 11 kv g.i. pins, i) 11 kv disc insulator (b & s type) 70 kn (porcelain type), i) 11 kv disc insulator (b & s type) 120 kn (porcelain type), j) 33kv disc insulators (polymer type), k) 33 kv post insulator, l) 22 kv post insulator, m) 11 kv post insulator, n) drive insulator of sorts, o) shackle insulator, p) 11 kv guy insulator, q) 33 kv guy insulator, 33 kv tension fittings for acsr dog conductor, b&s 3 u-bolts type, 33 kv tension fittings for acsr wolf

State Government

CTN :45296419 Due date: 08 Jun, 202608 Jun, 2026 NA
Tender For providing of custom bid for services - new transformer installment/augumentation of transformer/strenghtening of 11kv/lt electric line etc work in business plan 2026-27 under edd jhansi

Central Government/Public Sector

CTN :45220322 Due date: 25 May, 202625 May, 2026 NA
Tender For auction sale of rolling stock - condemned electric loco no.23479 wag5ha eddx as is where is condition with all available ferrous -non ferrous-wooden fittings- excluding the following reclaimable items- (1) wheel set with bull gear- 6 sets (2) axle box with ferrous components-12 nos. removed items- (1) battery-10 nos (2) head light-2 nos (3) cab fan-4 nos (4) cab fan transformer(tfvt)-1 no . loco no- 23479 wag5ha. ds8 no. 063630-25-07381 dt:12-02-2026 location: dsl-ed. cus- sse-dsl-ed. pl.no. 98980889. note: (1) two smoothning reactors available in shed floor saleable. (2) rc items to be handed over to custodian at specified location before final delivery. (3) cutting permitted to loadable size only. (4) crane loading permitted. (5) purchaser should take safety precaution while cutting of loco.(6) at the time of delivery all items including zero value items such as rexene, rubber, frp etc., should be removed and cleared by purchaser from railway premises and should be disposed as per the existing norms of central/state government.

State Government

CTN :45028919 Due date: 25 May, 202625 May, 2026 NA
Tender For supply of line materials under electric supply area medininagar - electrical items :, hot dip galvanized from fabricated iron materials - 33 kv v cross arm (100x50x6) 19.7 kg (galvanized) for rail , 33 kv pole top bracket (100x50x6) 2.9 kg for rail (galvanized), , back clamp for 33kv v cross arm for rail 3.2kg, , 33kv dp channel (100x50x6mm) 45.5kg, , support clamp for 33 kv dp channel for rail 1sets=4pairs 9kg, , 33 kv v cross arm (100x50x6) 19.7 kg (galvanized) for psc pole 400 kg. 19.2kg, , 33 kv pole top bracket (100x50x6) 2.9 kg for 400kg.psc pole (galvanized), , 33kv tapping channel (100x50x6) mm 23 kg, , back clamp for 33kv cross arm for psc pole 400kg.3 kg, , 33kv dp channel (100x50x6) mm 45.5 kg, , support clamp for 33 kv dp channel psc pole 400kg. 1sets=2pairs 6kg, , side stay clamp 400 kg psc pole (galvanized) 1.92kg, , angle stay clamp 400 kg psc pole (50x8) 1.92 kg (galvanized), , 33 kv cross bracing for dp structure (50x50x6) 64.3 kg 1 set=4 pc, , clamp for cross bracing suitable for rail/psc pole 400 kg 1 set 4 pc 3.6 kg, , 11kv v cross arm (100x50x6) 14.6 kg (galvanized) for psc pole 200 kg., , 11 kv pole top bracket (100x50x6) 2.1 kg for 200kg.psc pole (galvanized), , back clamp for 11kv cross arm for psc pole 200kg. 2.8kg, , 11kv dp channel 75x40x6mm 41.3 kg, , support clamp for 11 kv dp channel psc pole 200kg. 1sets 2pairs 4.4 kg, , 11kv tapping channel 75x40x6mm 21 kg, , side stay clamp 200 kg psc pole (galvanized) 1.08kg, , angle stay clamp 200 kg psc pole (50x8) 1.08 kg (galvanized), , 11 kv cross bracing for dp structure (50x50x6) 64.3 kg 1 set=4 pc, , clamp for cross bracing suitable for rail/psc pole 400 kg 1 set 4 pc 3.6 kg, , transformer base channel for dss 1set=2pc 52.63kg, , top channel for dss (100x50x6mm) 52.63kg 1set=2pc, , channel for hg fuse set 1set=-2pc 38.6 kg, , channel for ab switch (100x50x6mm) 52.63 kg 1set=2pc, , support clamp for dss 1set=2pair for 11 kv top, , channel/ab switch base channel/tr base channel & hg fuse set channel 9.6 kg, , transformer belting (50x50x6 mm) & belting support (40x40x6 mm) [galvanized] (52.3 kgs.), , lt distribution bus bar (35x35x6mm) 1set=2pair, , 33kv ab switch structure (549 kg)/set, , 11kv ab switch structure (549 kg)/ set, , 33kv post insulator structure (55 kg/)/set, , 11kv post insulator structure (55 kg)/ set

State Government

CTN :45277687 Due date: 11 Jun, 202611 Jun, 2026 14.92 Crore
Tender For design, engineering, supply, erection, testing and commissioning of 220kv and 33kv gis transformer/reactor bays along with associated works at 220kv sub station electric lane and trauma centre (aiims) on turnkey basis.

CTN :45222216 Due date: 29 May, 202629 May, 2026 NA
Tender For rate contract for supply, erection/creation, testing and commissioning of 400 kva transformer substation along with laying of ht and lt line on turnkey basis under the jurisdiction of executive engineer electric division vijaypur, jpdcl, jammu

CTN :45117319 Due date: 02 Jun, 202602 Jun, 2026 NA
Tender For supply of oil pump for transformer of wag9 type electric locos as per clw s spec. no.-clw/es/3/0106 (alt.-f). [ warranty period: 30 months after the date of delivery ]
 Loading, Please wait...

Connect us via What's Up