Get complete information related to latest Transformer Plinth Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Transformer Plinth Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Transformer Plinth Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45473828 Due date: 07 Jul, 202607 Jul, 2026 75.89 Lacs
Tender For corrigendum : construction of transformer plinth with overhead gantry crane, cc road, paver block & demolition of old quarters and transformer plinth at una ph campus under amreli circle.

Central Government/Public Sector

CTN :45713858 Due date: 18 Jul, 202618 Jul, 2026 25.00 Lacs
Tender For repair maintenance of various types of summer appliances and other connected items at af station jammu and kaluchak under ge (af) jammu - repair to split ac and window ac, supply of labour only for attending and rectification of daily complaints for day to day maintenance and servicing for split ac/window ac /hot & cold air conditioner/dual inverter air conditioners/flame proof ac of any capacity and make installed in various locations of 23 wing af jammu and 256 su kaluchak (excluding sundays and holidays) with high skilled refrigerator mechanic and helper including detecting fault of split/window air conditioner complain and servicing all unserviceable parts for split/window ac and replacement of u/s parts & repair of all necessary items and handed over to user for serviceable condition within 24 hours for minor faults and within 48 hours for major faults all as specified and direted by engineer in charge.note: (a) contractor has to employ highly skilld refrigerator mechanic with helper and necessary t&p for attending day to day complaints of ref and ac failing which recovery shall be made at two times of quoted rate. (b) rate quoted shall be inclusive of transport from af station to work shop & back shifting within permises.( c) any parts shall be replaced and paid separately as "supply only " against relevant item (s) of this schedule. , m&l for shifting of split type ac/ window type ac capacity upto 2 ton , including submain/point wiring all electrical items and drilling, making good on surface of pcc concreting, white cement plastering and all necessary items and transporting complete one location to other location in 23 wing area and 256 su kaluchak area replacing unserviceable parts and handing over the machine/ equipment in serviceable condition to the user including fixing to new location all as specified and directed by engineer-in-charge., supply only the following items to incorporate against repairable summer appliances window / split type acs against relevant items no 2.00 and 3.00 here-in- before: -, blower motor complete suitable for window type ac upto 2.0 ton all as specified and directed by engr-in-charge., indicator suitable for window type ac up to 2 tonall as specified and direted by engineer in charge., thermostat switch suitable for window type ac up to 2 tonall as specified and direted by engineer in charge., control knob suitable for thermostat switch and selector switch of window type ac up to 2 tonall as specified and direted by engineer in charge., selector switch suitable for window type ac up to 2 ton all as specified and direted by engineer in charge., relay along with box suitable for window type ac upto 2 ton all as specified and direted by engineer in charge., plastic air filter suitable for window ac upto 2 tr. make- voltas/ bluestar/ lg/ samsung/ as on site., outer unit condenser fan motor suitable for window type ac up to 2 ton. make- voltas/ bluestar/ lg/ samsung/ as on site., fan for outer unit condenser motor suitable for window type ac up to 2 ton. make- voltas/ bluestar/ lg/ samsung/ as on site., front grill as per existing suitable for window type ac upto 2 ton.make- voltas/ bluestar/ lg/ samsung/ as on site., plastic air filter suitable for split ac indoor unit ac upto 2 tr. make- voltas/ bluestar/ lg/ samsung/ as on site., s&f power control board ( pcb ) for window type /split ac up to 2 ton . make- voltas/ bluestar/ lg/ samsung/ as on site., s&f power control board ( pcb ) for split ac indoor unit dual inverter/hot and cold ac up to 2 ton . make- voltas/ bluestar/ lg/ samsung/ as on site., s&f power control board ( pcb ) for split ac out door unit dual inverter/hot and cold ac up to 2 ton . make- voltas/ bluestar/ lg/ samsung/ as on site., wiring kit suitable for split ac and window type ac upto 2 ton., condenser fan motor complete with fan suitable for out door unit of split type air conditioner upto 2 ton. make- voltas/ bluestar/ lg/ samsung/ as

corporations/Associations/Others

CTN :45711581 Due date: 03 Jul, 202603 Jul, 2026 37.20 Lacs
Tender For strengthening work of 33 kv line, strengthening work of 11 kv line, strengthening and protection of 33 11 kv sub-stations, 11 kv vcb work, 33 kv vcb work, switch yard work 11 0.4 kv distribution transformer plinth fencing earthing work bp 2026-27

State Government

CTN :45640057 Due date: 06 Jul, 202606 Jul, 2026 70.00 Lacs
Tender For supply of fuse set from esc mnp , carriage of 11 kv tpmo with polymer insulator from esc mnp , carriage of complete stay 9gi stay rod 20x1800 mm etc material from esc mnp , carriage of distribution transformer 25 kva from esc mnp , carriage of distribution transformer 63 kva from esc mnp , carriage of distribution transformer 100 kva from esc mnp , carriage of distribution transformer 250 kva from esc mnp , carriage of acsr weasel conductor from esc mnp , carriage of m s earthing rod 20 x2540 mm from esc mnp , carriage of lt al. xlpe cable size 1x240 sq.mm. from esc mnp , carriage of lt xlpe cable 1x120 sq.mm. for dtr from esc mnp , carriage of lt xlpe cable 1x400 sq.mm. for dtr from esc mnp , carriage of lt xlpe cable size 3.5x70 or 35 sq.mm. from esc mnp , carriage of lt ab cable 3x120 1x95 1x16 sq.mm. from esc mnp , carriage of lt ab cable 3x50 1x35 1x16 sq.mm. from esc mnp , carriage of lt ab cable 3x95 1x70 1x16 sq.mm. from esc mnp , carriage of 33 kv xlpe cable 3x300 sq.mm. from esc mnp , carriage of 33 kv indoor or outdoor jointing kit size 3x300 sq.mm. from esc mnp , carriage of 33 kv straight through size 3x300 sq.mm. from esc mnp , carriage of g.i. wire 6 or 8 swg for guarding from esc mnp , carriage of three phase distribution box from esc mnp , erection of fixing of lt fuse set protection box with all respective accessories as per norms , execution of chemical earthing with g.i. patti clamp nut and bolts as per norms , erection of l.t. tail less unit with all respective material as grouted angel with fabrication work etc. , laying of acsr weasel conductor , laying of lt ab cable 3x120 1x95 1x16 sq.mm. , laying of lt ab cable 3x50 1x35 1x16 sq.mm. , laying of lt ab cable 3x95 1x70 1x16 sq.mm. , mounting of three phase distribution box , erection of double pole structure 8.5 mtr pcc pole , erection of single pole structure 8.5 mtrs pcc pole , erection of tri pole structure 33 kv 13 mtr st pole , grouting of pcc or stp pole , grouting of stay , earthing of pole , guarding of 11 kv line , fencing of 250 kva distribution transformers , plinth for 250 kva transformer , installation of 11by0.4 kv tf 25 kva , installation of 11by0.4 kv tf 63 kva , installation of 11by0.4 kv tf 100 kva , installation of 11by0.4 kv tf 250 kva , laying of 33 kv xlpe cable 3x300 sq.mm. , installation of 33 kv indoor or outdoor jointing kit size 3x300 sq.mm. as per norms. , dismentlling, received back and safe carriage of jarjar g.i. wire and weasel conducter including with rolling from pit site to esc, mainpuri , received back of distribution transformer after increasing capacity from pit site to esc, mainpuri

corporations/Associations/Others

CTN :45263412 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For corrigendum : supply of 4500 sets of stay set complete - supply of silicagel blue, 0.6kva ups, stay set complete( quote price for single unit only), silicagel blue 10 to 12mm, pole pit for 9.0m and 9.14 m psc/rcc / all metal poles (each pit) 1.25 x 0.6 x 1.83 mtr, ordinary soil, semi rocky soil, heavy rocky soil where blasting/ cheseling required [specific approval should be obtained from concerned ee], stay pit, in ordinary soil [0.95 x 0.6 x 1.2m], semi rocky soil, stay pit in heavy rocky soil where blasting/ cheseling reqiured [specific approval should be obtained from concerned ee], erection of poles & stays (including refilling of excavated earth), erection of 7.5m / 8.0m poles [rcc / psc], erection of 9.00m / 9.14m rcc / psc/rail pole, tubular pole and all metal poles, stay set, erection stay set complete, stay erection without rod and pit, replacement of stay rod only. (including stay pit excavation & refilling & erection), replacement of guy shackle only in existing stay, erection of line materials, fixing of lt 1 ph "x" arm, fixing of lt/ht ti fitting, fixing of lt 3 ph "x" arm, fixing of 3[1/2] v ` x arm, fixing of 4[1/2] v ` x arm, fixing of 5 v x arm, fixing of tapping channel / guarding "x" arm, providing of line spacers in lt lines 1 phase, providing of line spacers in lt lines 3 phase, erection of ab switch with pt insulator & jumpering complete, erection of centre rotating switch ab switch complete, fixing of ht pin insulator / strain disc, 11 kv pin insulator with pin, 11 kv strain disc / polymer disc with hardware, 22 kv pin insulator with pin, 22 kv strain disc / polymer disc with hardware, 33 kv pin insulator with pin, 33 kv pin strain disc/polymer disc with hardware, fixing of lt pin insulator with pin, lt shakle with hardware, fixing of aluminium knob, paving stringing and sagging of conductor including binding of pin and proper tight [including transport of condutor from road side to work spot] per run, upto 7/2.59 mm acsr, 7/2.50 aaac including pvc cable upto 25 sqmm, acsr 7/3.35mm & 7/ 3.15 aaac including pvc cable above 25 sqmm, acsr 7/4.09 mm, above 7/4.09 mm acsr & dog conductor, earthing wiring and connection including transporting of earth pipe and excavation of pit], transformer structure earthing 10ft depth - 3 nos of pipe through tubes, dp earthing including all works [double side earthing], erection of 4th earth pipe including earthing, earthing of poles, earth pit masonary work 3 nos earth pits or using 3 nos concrete tub., replacement of detoriated earth pipe per location, concreting with mixture 1:3:6 [including all materials]., mass concreting for centre support for 2 feet including all materials, mass concreting for pole0.6x0.6x1.25m.with coping, sleeve concreting for pole 0.6 m x 0.6m x 0.3 m with coping, sleeve concreting for stay set 0.3 m & 0.75 long, erection of distribution transformer structure complete, excavation of structure pole pits 0.9 x 0.9 x 1.83 mtr, transporting of pole to pit location 2 nos., erection of poles 2 nos, excavation of stay pit 4 nos, erection of stay set (4 sets), mass concreting (cement:sand:jelly supplied by the contractor) 2 nos., erection of 22 kv ab switch, ttransformer structure earthing 10ft depth - 3 nos of pipe through earth tubes, erection of top channel, bed channel [2 nos channel] erection, cross with stud for bed channel erection, erection of belting angle / hg fuse angle, erection of hg fuse set, erection of ht las with jumpering and earthing, erection of lt las with jumbering and earthing, erection of jumpering [ht side], transformer wiring in lt side including jumpering bus bar etc., erection lt open type fuse unit arrangement single, erection lt open type fuse unit arrangement double, painting of stru. complete excluding dt [two coat of red oxide] all metal parts(excluding cost of paint)., painting of stru. complete excluding dt [one coat alu paint, excluding cost of paint), colour washing of 2 numbers structure p

CTN :45451320 Due date: 22 Jun, 202622 Jun, 2026 NA
Tender For corrigendum : providing of facility management services - lumpsum based - construction of transformer plinth boundary wall repair and height raising main gate installation and plinth fencing works at electricity store centre balrampur; civil works; consumables to be provided b..

CTN :45590344 Due date: 22 Jun, 202622 Jun, 2026 25.80 Lacs
Tender For fencing of transformer plinth, repairing of transformer plinth and boaring type earthing at different placesunder executive engineer, 11 kv & lt vertical ayodhya dham, ayodhya.

CTN :45590350 Due date: 22 Jun, 202622 Jun, 2026 6.80 Lacs
Tender For fencing of transformer plinth, repairing of transformer plinth and boaring type earthing at different placesunder executive engineer, electricity distribution division-darshan nagar, ayodhya

corporations/Associations/Others

CTN :45596172 Due date: 23 Jun, 202623 Jun, 2026 37.20 Lacs
Tender For strengthening work of 33 kv line, strengthening work of 11 kv line, strengthening and protection of 33 11 kv sub-stations, 11 kv vcb work, 33 kv vcb work, switch yard work 11 0.4 kv distribution transformer plinth fencing earthing work bp 2026-27

State Government

CTN :45261763 Due date: 15 Jun, 202615 Jun, 2026 70.00 Lacs
Tender For corrigendum : supply of carriage of distribution transformer 25 kva from esc mnp , carriage of distribution transformer 63 kva from esc mnp , carriage of distribution transformer 100 kva from esc mnp , carriage of distribution transformer 250 kva from esc mnp , carriage of acsr weasel conductor from esc mnp , carriage of m s earthing rod 20 x2540 mm from esc mnp , carriage of lt al. xlpe cable size 1x240 sq.mm. from esc mnp , carriage of lt xlpe cable 1x120 sq.mm. for dtr from esc mnp , carriage of lt xlpe cable 1x400 sq.mm. for dtr from esc mnp , carriage of lt xlpe cable size 3.5x70 or 35 sq.mm. from esc mnp , carriage of lt ab cable 3x120 1x95 1x16 sq.mm. from esc mnp , carriage of lt ab cable 3x50 1x35 1x16 sq.mm. from esc mnp , carriage of lt ab cable 3x95 1x70 1x16 sq.mm. from esc mnp , carriage of 33 kv xlpe cable 3x300 sq.mm. from esc mnp , carriage of 33 kv indoor or outdoor jointing kit size 3x300 sq.mm. from esc mnp , carriage of 33 kv straight through size 3x300 sq.mm. from esc mnp , carriage of g.i. wire 6 or 8 swg for guarding from esc mnp , carriage of three phase distribution box from esc mnp , erection of fixing of lt fuse set protection box with all respective accessories as per norms , execution of chemical earthing with g.i. patti clamp nut and bolts as per norms , erection of l.t. tail less unit with all respective material as grouted angel with fabrication work etc. , laying of acsr weasel conductor , laying of lt ab cable 3x120 1x95 1x16 sq.mm. , laying of lt ab cable 3x50 1x35 1x16 sq.mm. , laying of lt ab cable 3x95 1x70 1x16 sq.mm. , mounting of three phase distribution box , erection of double pole structure 8.5 mtr pcc pole , erection of single pole structure 8.5 mtrs pcc pole , erection of tri pole structure 33 kv 13 mtr st pole , grouting of pcc or stp pole , grouting of stay , earthing of pole , guarding of 11 kv line , fencing of 250 kva distribution transformers , plinth for 250 kva transformer , installation of 11by0.4 kv tf 25 kva , installation of 11by0.4 kv tf 63 kva , installation of 11by0.4 kv tf 100 kva , installation of 11by0.4 kv tf 250 kva , laying of 33 kv xlpe cable 3x300 sq.mm. , installation of 33 kv indoor or outdoor jointing kit size 3x300 sq.mm. as per norms. , dismentlling, received back and safe carriage of jarjar g.i. wire and weasel conducter including with rolling from pit site to esc, mainpuri , received back of distribution transformer after increasing capacity from pit site to esc, mainpuri