Tender For [i] full wiring of bv siding taking off from rd-04 at mya.[ii] ohe modification in connection with proposed extension of pf-1 and pf-2 for a length of 95 mtrs width construction of 2 no's of pay and use toilet along with divyangjan toilets, drinking water booths, platform shelter at gnb station.[iii] ohe modification in connection with construction of pedestrian subway at trespassing location km 5/900-6/000 between sbc-nyh stations in aden/mya sub-division.[iv] provision of automatic signalling between mys-sbc section-trd works[v] recoupment of ballast at tss,sp/ssp and provision of cable trench covers-bid & mya depot[vi] provision of earthing and bonds at ssp/sp,fob and platform shelters in sbc division-bid & mya depot
Tender For corrigendum : work of installation of mesh type earthing at 66kv switchyard of 400kv kansari sub-station under deesa division of palanpur circle approved under r&m 22-23
Tender For repair and maintenance street light fitting stand by dg sets timer switch street light panels service connections earthing and otherconnected electrical works at alhilal mil station under ge palampur
Tender For corrigendum : repair/maintenance of dg sets, amf panels , control panels, voltage stabilizers, isolation transformers, air compressors ,earthing/lightning protection and connected work of different capacity in east wing and singhpur in tech area af station gwalior
Tender For supply, installation, testing and commissioning of 1600kva 11kv / 0.4kv compact sub-station (css) including earthing of css in mt hall at iit kharagpur campus, kharagpur.
Tender For corrigendum : supply of providing and laying of painting works , patch works , waterproofing works , dismantling false ceiling , dismantling bison board , dismantling woden partistion , window closing , dismantling existing washbasin , cleaning , room 3 , providing toilets , toilet renovation works , roofing and false celing works , room 9 , floor patch works , dismantling of toilets , dismantling damaged windows , room 14 15 , dismantling existing doors , repairs to existing ventilator windows , dismantling existing wall and floor tiles , structural repair and opening modification works , dismantling brick structure and floor repair , dismantling and vegetation removal , dismantling existing broken and damaged glass panes , cpvc water supply line , site clearance and general demolition works , anti termite treatment , rodent and pest control treatment , overhead water tank cleaning repair and disinfection , storm water drain and surface drainage , signage and room identification , comprehensive checking of 1 nos 250 kva outdoor type substations including inspection , aluminium paint , servicing of existing 11 kv 400 amps 3 pole gang operated type air break ab switch , supplying and replacing damaged or worn out copper metal , supplying and replacing damaged or defective 11 kv post top insulators , supplying and replacing damaged or defective 11 kv pin type insulators , servicing of earth pits , supply installation testing and commissioning lbs , xlpe insulated aluminium conductor armoured ht cable , providing indoor or outdoor type heat shrinkable , supplying and laying of 3.5 core x 240 sq.mm 1.1 kv grade aluminium conductor xlpe insulated , supplying and making end termination for 3.5 core x 240 sq.mm 1.1 kv grade , joint for existing single run lt power cable of size 3.5 core x 240 sq.mm , comprehensive servicing and preventive maintenance of existing ht transformer , supply, fixing, installation, testing and commissioning of lightning arrester , providing and fixing cable identification tags , supply, installation, testing and commissioning sitc main mv panel , supply, installation, testing and commissioning sitc cubicle pdb panel , supply, installation, testing and commissioning sitc feeder pillar box , providing and installation of maintenance free earthing station , supplying and laying of 3.5 core x 120 sq.mm 1.1 kv grade aluminium conductor xlpe insulated , providing laying and fixing of overhead perforated or slotted ms cable tray , supply installation testing and commissioning 7 segment distribution board , providing fabricating supplying, installing testing and commissioning of electrical socket box
Tender For corrigendum : repair/ replacement and maintenance of ht switchgear, vcb, rmu, lbs and transformer, cables, earthing and other connected items at gandhinagar military station
Tender For "electrification with 2 x 25 kv, 50hz a.c., single phase ohe work for construction of 4th line in sarona and kumhari yard and bonding & earthing etc. work in connection with 'replacement of pl with el at sarona and kumhari station' in raipur division over s.e.c.railway"
Tender For supply of miscellaneous electric items - steel tubular 9 mtr. long pole (st-410 sp33) , acsr weasel conductor 6/1/2.59 mm , 11 kv go, ab switch 3-phase, 3-pole, 200 amp vertical type with rod heavy duty , back clamp for 9 mtr. pole with fitting , 11 kv horn gap fuse set (hg set) 3-phase 400 amp polymer type heavy duty , la set station type (gapless surge arrestor, 9kv, 10 ka, la with polymer housing station type heavy duty) , xlpe pvc cable single core 300 mm sqr. (300 sq mm cable 1.1 kv grade, pvc insulated standard conductor frls type) , 11 kv polymeric pin insulator 12 kv, 5 kn, lighting impulse 75 kv positive and 80 kv negative, creepage distance 320 mm , insulator disk 11 kv (11kv polymeric composite discs insulator with pin and gl fittings, 12 kv, mainfalling load 45 kn, lighting impulse 75 kv positive and 80 kv negative, creepage distance 320 mm) , channel 100.00 mm x 50.00 mm x 5.00 mm (10 feet long) , nut bolt full thread with washer 4"/6" heavy duty , wedge connection / pg clamps , danger plate and clamps , g.i. bracket wire for anti climbing , 3 phase 4 wire trivector meter with ct/pt unit , aluminium thimble 185 mm , lv distribution box for 400 kva dtr with mccb for incomer & sfu's for outgoing circuits , stay set (gi rod with clamp) - galvanised stay set with 50x8mm stay clamp, gav. insulator (02 nos.) anchor plate (200x200x6mm) nut-bolt 2 nos. turn-buckles, 1.8 m long 16 mm diameter solid g5 stay rod & 7/3. 15 mm dia gi standard wire complete , g.i. guy rod complete with clamp and insulator , anti climbing device with clamp , guy / stay wire 7/14, galvanized steel, typically hot-dip zinc-coated for corrosion resistance , giv cross-arm with top bracket and gi channel-arm including clamp (gi v cross arm with top bracket including clamp and gl channel x-arm including clamps and braces) , channel 75 x 75 x 6mm (10 feet long) , g.i. earthing wire 8/10 mm