Tender For supply of following items for setting up measurement and instrumentation lab for 4 year b.tech in electrical engineering curriculum and application for university of calcutta. - experimental set-up for calibration of a wattmeter using dc potentiometer with following features/items:regulated power supply 2 volts, 100 ma to operate the potentiometer.calibrated electronic standard cell voltage 1.0186 volts.regulated power supply 0-5 volts/0.5 amps with milliammeter 0- 500ma for current coil of wattmeter.regulated high voltage power supply 0-250 dc volts with voltmeter 0-250 volts for pressure coil of wattmeter.a panel mounting wattmeter 0-125 watt is required to perform the experimentgalvanometer for null balance.a volt ratio box for measurement of higher voltage.complete circuit diagram with wattmeter connections to be provided on the front panel of the instrument.with standard accessories, experimental set-up for low resistance measurement using kelvin s double bridge with following features:range: 0.2 micro ohm to 11 ohms, with an accuracy of 0.05 %required accessories:spot reflecting galvanometer. dc source 10 a with one analog current meter. attachment of 1 meter length.brass clamp with terminals for zero setting. with standard accessories, experimental set up for unknown capacitance measurement using de-sauty s bridge with following specifications:source: sine wave signal of 1khz. the amplitude of ac switch indicating lamp is provided on the bakelite board. two sockets are to be provided for the output of ac signals.detector: for detecting small ac signals in the output, null detector is required as in-built with digital display.circuit diagram:the circuit layout on the board is to be provided out to facilitate convenient working. 4 or 5 mm socket required for making connection. features:r2 --- three decade resistance dials having value 10 1000, 10 100 and 10 10 ohmsr1 ---- single decade resistance dial having value 10 100 ohmsc1 ---- unknown capacitor.c2 ---- two fixed standard capacitors having value 0.01mfd 0.1mfd (loss free)with standard accessories, experimental set-up for calibration of a 1-phase watt-hour meter with following scopes: to adjust & calibrate a single-phase energy meter by direct loading method to adjust & calibrate a single-phase energy meter by comparing with a sub-standard meterspecifications: static energy meter single phase: under test (local) duly mounted, wired and terminated static energy meter single phase: sub-standard meter (isi mark) duly mounted, wired and terminated voltmeter: moving iron ac portable of class 1.0 accuracy and range 0 - 300 v ac ammeter: moving iron ac portable of class 1.0 accuracy and range 0 - 10 a ac wattmeter: dynamometer type ac single phase, multi-range with current coil 5 / 10 amp and potential coil 75 / 150 / 300 v ac variac: variable voltage transformer (portable table / floor mounting type with enclosure) input: 230v ac and output: 0 270v / 8 amp ac variable load: made up of 3 load resistors of 70 ohms / 700 w each duly mounted and connected / terminated to form different loads (35 to 210 ohms) as per external connections digital stop clock: portable with start / stop & reset operation set of necessary 4 mm spring loaded patch cords for interconnections detailed instruction manual supply to be connected: 230v, 1phase, 50 hz, ac mains, experimental set-up for calibration of a 3-phase watt hour meter with following specifications: to adjust & calibrate a three-phase energy meter by direct loading method to adjust & calibrate a three-phase energy meter by comparing with a sub-standard meterspecifications:static energy meter three phase: under test (local) duly mounted, wired and terminatedstatic energy meter three phase: sub-standard meter (isi mark) duly mounted, wired and terminatedvoltmeter: moving iron ac portable of class 1.0 accuracy and range 0 - 300 v acammeter: moving iron ac portable of class 1.0 accuracy and range 0 - 10 a acwattmeter:
Tender For tender for supply of 3phase charger card , model i4 hpn-207-g for (2x160) kva ups , make hi-rel , gate driver igbt , model i4 hrd-047-d for (2x160) kva ups , make hi-rel , rating 300a+ , buffer driver card , model i4 hrd-098c for (2x 160 kva) ups , make hi-rel , igbt 150/600v for cwpt ups(2x 5kva) make hi-rel , system control card , model i4 hrd-046c for (2x160) kva ups , make hi-rel , 3 phase charger card , model hpn-207-g for ups , make hi-rel , switcher card i4 , model i4 hrd-269-0 for (2x 160 kva) ups , make hi-rel , transformer , rating 500va , 415/215 for (2x 160 kva) ups , make hi-rel , i4 gate driver card , model hrd-047d for ups , make hi-rel , mag/i4 smps card , model hrd-268-0 , uc3844 30batt for (2x 160 kva) ups , make hi-rel , dc bus sensing card , model i4 hpw-043-b for ups , make hi-rel , rectifier snubber card , model hpw-006c for ups , make hi-rel , control transformer for switcher card for (2x 160 kva) ups , make hi-rel , control transformer , rating 500va , 415/230v , model xmer cntl for (2x 160 kva) ups , make hi-rel , transformer , rating 250va , 415/180-200-230 for (2x 160 kva) ups , make hi-rel , hylam series regulator card , model i4 for (2x 160 kva) ups , make hi-rel , capacitor panel for (2x160) kva ups , make hi-rel , rating 450v 3300uf , 20% radial , cooling fan 8 inch (spare for 2x75 kva ups) , card , hrd-571 , manager 2x160kva , make hi-rel , semi conductor fuse (gsi 1000v/250a/600v) for battery charger , semi conductor fuse (gsi 1000v/300a/600v) for battery charger , current transducer for ups , supply 230 volt ac , i/p 0-5 a. 50/60 hz , o/p 4-20 ma , voltage transducer for ups , supply 230 volt ac , i/p 0-300v. 50/60 hz , o/p 4-20 ma , capacitor panel paper for (2x160)kva ups , make hi-rel , rating 370v 93/100mf , 10% radial
Tender For notice inviting e-tender for supply, installation and demonstration of different equipments, instruments, trainer kits, models, study setupsetc. for different laboratories of electrical engineering department,dr. meghnad saha institute of technology, - complete trainer board of andersons bridge ( measurement of inductance), schering bridge to measure unknown capacitance, trivector meter, complete set-up for the extension range of ammeter and voltmeter by using shunt and multiplier., complete set-up for the extension range of ammeter and voltmeter by using ct and pt, complete trainer board of wheatstone bridge ( measurement of medium resistance), complete trainer board for verification of nortons theorem, delta connected load box with each arm variable inductor, capacitor and resistor, complete set-up for measurement of energy using ct or ct and pt, led lamps, 5w, 230v, led lamps, 10w, 230v, led lamps, 15w, 230v, led lamps, 20w, 230v, diac characteristics trainer kit, digital oscilloscope, half wave-controlled rectifier with resistive load and determine the load voltage., half wave bridge rectifier trainer kit, full wave bridge rectifier trainer kit, rheostat, rheostat, rheostat, rheostat, fully automatic star delta starter, make & test the control and powercircuit for forward and reverserotation of sq. cage induction motorusing contactor circuit., make & test the control and power circuit for automatic star-delta starter operation of sq. cage induction motor using contactor control., laboratory module for measuring solar radiation using pyranometer on tilted surface at different angles of inclination., laboratory module for solar photovoltaic cell to plot i-v characteristics and to find out the solar cell parameters (o.c. voltage, short circuit current, voltage-current-power at maximum power point, fill factor, efficiency)., laboratory module for measuring thermal performance of a solar cooker with varying reflector., cut section model of water turbine (francis, kaplan, pelton), laboratory module for solar pv plant to produce electricity, laboratory module for wind power plant of with a small wind turbine to produce electricity, kit for testing mcb & hrc fuse by performing the load test, mcb -6a, kit for testing mcb & hrc fuse by performing the load test, mcb -10a, kit for testing mcb & hrc fuse by performing the load test, mcb -1a of hrc fuse, kit for testing mcb & hrc fuse by performing the load test, mcb - 5a of hrc fuse, laboratory module for dismantling mccb/elcb/ rccb and identifying various parts, testing of induction type/ microprocessor based over current relay using relay testing kit, testing of static distance protection relay using relay testing kit, testing of static over current protection relay using relay testing kit, testing of directional over current relay (docr) by relay testing kit, testing of percentage differential protection of transformer using transformer differential relay (microprocessor based/static), laboratory module to study of different lightning arrester and identify different parts, laboratory module to study of acb/vcb and identify different parts, laboratory module for performing insulation resistance test on any one motor/transformer
Tender For annual servicing and overhauling of ht/lt equipment at garvi gujarat, new delhi-servicing and overhauling of vcb operatingmechanism, cleaning of contacts & insulatorsand making circuit breaker electrical operationalfrom tnc switch.testing of 11 kv vcb panels as per test detailsgiven below:a) high pot testing of each pole to checkhealthiness of vacuum interrupter and itsinsulators.b) high pot testing pf main bus bar.c) insulating testing of vcb in close and openposition.d) removing of moisture and sulfation from ct'sspouts and other insulators and providing reinsulation on these parts.e) testing of thermostatically controlled 230v acspace heaters in the ct's and cable endchamber.f) servicing and high voltage testing of the vcb.g) testing and servicing of ct & pt.h) testing and servicing of primary busing rod.i) testing and servicing of bus-bar supportinginsulator 400 amp.j) testing and servicing of rose contact3 nos ``02 testing and calibration of idmt protective relay2 o/current and 1 e/fault for ht and lt panelwith primary injection set.08 nos03 servicing and overhauling of different rating acbof capacity 2000 amp 5nos, 1250 amp 4 nos,operating mechanism, cleaning carbon fromcontacts & insulators and making circuitbreaker electrical operational from switch andsetting of tripping mechanism of acb,adjustment of contact spring and setting ofinbuilt protective device.12 nos04 servicing, testing of capacitor panel of capacity305 kvar i/c calibration of apfcr relay at site.02 nos05 servicing, cleaning and testing of dry type transformer ofcapacity 1250 kva, 11 kv/440 v 3 phase transformerincluding performing the following tests as per is standard:a) ir valueb) magnetic currentc) voltage ratiod) high voltage teste) core balance tests