Tender For provision of over run line at dn 1st loop and 2nd loop at sonnagar station and bagohi kusa - increasing of up long haul loop line at least upto 1400 mtr. for accommodating long haul trains.
Tender For 1. proposal of 2nd loop line at hind & nnx in the section of sse/p.way/smql under aden/smql.and 2. rag picking work in the section of sse/p.way/gzb-i & ii under aden/gzb in jurisdiction of sr. den-ii/dli.
Tender For restoration of setteled outfall deep sewer line by providing and laying loop line of 400mm dia dwc sn 8 pipe at gate no. 03, infornt of h. no. 14, du block, pitampura, ward no. 57 shalimar bagh ac-14 under ee (d)-61
Tender For providing new loop line for the length of 600m at jaipur-i and ii under badamnallah section under sub division no.iii, swadeshnagar, nacd, apwd, mayabunder under jal jeevan mission
Tender For improvement of water supply in gali no. 18j and surrounding area by providing and laying loop line of 160 mm dia from main kailashpuri road to kanwal bharti school in sadh nagar ward ac-37 palam constitunecy under ee(d)-095.
Tender For special repairs replacement to e/m equipments and infrastructure at af stn jamnagar under ge (af) jamnagar no 1 - supply, installation and testing air cooled inverter based split ac unit with cooling functions and suitable to operate at ambient conditions of (22 deg c + 3 in cooling mode) air conditoner will have following conditons :- (a) refrigerant - r-410 a/r-32 (b) eer- 5 star rating (c) tonnage - 1.5 tr (d) indoor noise level - not more than 40 db (e) filter - as recommended by oem (f) remote - as recommended by oem including 02 nos remote bty (g) temp display, turbo mode and auto swing facility all specification will be as per is-1391 (part 2) and latest amendments as specified as directed by engineer-in-charge., supply, installation and testing air cooled inverter based split ac unit with cooling functions and suitable to operate at ambient conditions of (22 deg c + 3 in cooling mode) air conditoner will have following conditons :- (a) refrigerant - r-410a/r-32 (b) eer- 5 star rating (c) tonnage - 2 tr (d) indoor noise level - not more than 40 db (e) filter - as recommended by oem (f) remote - as recommended by oem including 02 nos remote bty (g) temp display, turbo mode and auto swing facility all specification will be as per is-1391 (part 2) and latest amendments as specified as directed by engineer-in-charge., note for item no 1 & 2 :- the cost of following items deemded to be included in quoted rate.(a) copper pipe duly insulated between indoor/outdoor unit upto lenght 10mtr for each unit (b) ms bracket for outdoor unit duly power coated with fixing arrangement.(c) making of hole in walls including civil work , sleeves and making good to the disturbed surface/wall.(d) testing and commissioning of the air conditioner to the entire satisfaction of engineer in charge(e) pvc round sheathed copper cable of suitable size for connecting indoor and outdoor unit upto supply point as per site requirement (f) taking down of existing ac and deposited to e/m store yard without any damage., supply and installation of voltage stabilzer for automatic operation single phase naturally air cooled indoor type and designed for input varioution between 180v to 250v without voltage stabilzed at 230v with accuracy of (+) 2.5% and capacity 4 kva as specified as directed by engineer-in-charge., supply and installed voltage stabilzer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 180v to 250v without voltage stabilzed at 230v with accuracy of (+) 2.5% and capacity 5 kva as specified as directed by engineer-in-charge., material & labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4.0 sqmm each, pvc insulated, unsheathed, fire retardant, low smoke (frls) drawn through and including pvc casing capping with all necessary fitting and including one run of single core multistranded copper conductor cable, of size 4.00 sqmm, pvc insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete all as specified and as directed by engr-in-charge.note: 2 runs of main copper conductor, one run earth wire and pvc casing capping will be measured as one running meter for payment., s&f sheet metal enclosure , 20a single pole and neutral with a two pin and earth plug and socket complete in metal clad board (industrial type) with one single pole mcb 32 amp fixed properly on in concealed position all as specified as directed by engineer-in-charge., supply, installation, commissioning and testing in replacement of loop card having 254 devices of both detectors and modules in a single line circuit, slc supports both class a and class b wiring complete as specified and as directed by engineer-in-charge. make: ravel/honeywell/ceasefire industries pvt ltd, supply, installation, commissioning and testing in replacement of addressable smoke detector with base with binary coded address setting. dual leds for 360 visibil
Tender For i) macls indoor and outdoor works along with provision of electronic interlocking at proposed terminal station at akot station and telecommunication related works between akola jn - akot of nanded division of s.c.railway. ii) trenching, laying of hdpe duct & cables, blowing, back filling, jointing splicing and termination of 6 quad cable, optical fiber cable and indoor telecom equipments installation works between tukaithad-khirki-khaknar kalan(15.50km) of nanded division of s.c.railway. iii) macls indoor and outdoor works along with provision of distributed electronic interlocking at nizamabad jn in view of doubling between mudkhed - medchal and yard arrangements for providing additional loop line and providing additional platform at nizamabad station of hyderabad division of s.c.railway.