Web Analytics Made Easy - StatCounter

Transmission Line Service Tenders

Get complete information related to latest Transmission Line Service Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Transmission Line Service Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Transmission Line Service Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45389601 Due date: 28 Jul, 202628 Jul, 2026 NA
Tender For corrigendum : tender for request for proposal (rfp) for appointment of authority engineer for providing project management services for design and construction of new rail cum road bridge no.11 over river ganga, 50 meters downstream of the existing old malviya bridge near kashi railway station, including sub structure and super structure of the bridge (8 x 108.5 m + 2 x 103.3 m open web steel girder) for four line tracks on lower deck and six lane road on upper deck, including railway and road approaches as per gad along with associated ohe works and general electric works in lucknow division of northern railway at varanasi, uttar pradesh, india

Central Government/Public Sector

CTN :45743875 Due date: 28 Jul, 202628 Jul, 2026 NA
Tender For request for proposal (rfp) for appointment of authority engineer for providing project management services for design and construction of new rail cum road bridge no.11 over river ganga, 50 meters downstream of the existing old malviya bridge near kashi railway station, including sub structure and super structure of the bridge (8 x 108.5 m + 2 x 103.3 m open web steel girder) for four line tracks on lower deck and six lane road on upper deck, including railway and road approaches as per gad along with associated ohe works and general electric works in lucknow division of northern railway at varanasi, uttar pradesh, india

Central Government/Public Sector

CTN :45730826 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For supply of product- hot bain marie, - size: length- 48 inch, height- 34 inch, frame size- 1.5 inch x 1.5inch stainless steel pipe(+- 10 %) , - ss 304 grade material, sheet thickness - 16 gauge, - 6 containers each of 7 lt capacity, total 42 lt (+- 10 %), - 1 kw electric heater with automatic temperature controller. - drain line wall- bottom storage shelf- adjustable legs, - 1 year warranty, - free installation and demo [ warranty period: 12 months after the date of delivery ] ]

State Government

CTN :44231929 Due date: 13 Jul, 202613 Jul, 2026 NA
Tender For corrigendum : supply of various consumable material at emd -1 lighting dept. stps. - flat cable 3 corex4 sqmm with copper conductor for submersible motor, flexible copper wire 1 corex2.5 sqmm (36/0.3 mm)1100v(1 coil is equal to 90 meter), flexible copper wire 1 corex1.5 sqmm (22 / 0.03) voltage grade up tp 1100 volt conf to is- 694, copper cable 2 cx1.5 sqmm, pvc twin wire 2.5mm sqr., self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of red colour, self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of yellow colour, self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of blue colour, self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of black colour, self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of green colour, porcelin kit kat fuse 16 amp, porcelain kit kat fuse 63 amp, 415 v , ac, porcelain kit kat fuse 100 amp, 415 v , ac, porcelain kit kat fuse 200 amp, 415 v , ac, din rail mounting channels, ring spanner set model 1812 taparia make, double ended spanner set dep 12, adjustable screw spanner size 8" (200 mm) p.no.1171-8 p, screw driver (tester) taparia product no: 818.special with neon bulb, generally confirming to is 5579-1985 grade - ii, yellow handle,, taparia combination plier, product no.1621-8,210 mm, digital insulation tester, range-0-2000 m-ohm, selectable test voltage-250/500/1000 v dc with rechargeable battery, digital clamp on meter lcd display with backlight, 3-3/4 digit., alluminium ladder self supported a type having 05 feet length, long nose plier insulated with thick c.a. sleeve,165 mm length, taparia make tool, allen key set, product no aki 10, allen key set mm size (09 piece) 1.5,2,2.5,3,4,5,6,8,10 mm, hand drill machine size 13mm, hand grinder machine., aluminium tube terminals10.0 mm2, m.6, aluminium tube terminals16.0 mm2, m6, aluminium tube terminal 35 sqmm,m 8, aluminium tube terminals50.0 mm2, m10, aluminium tube terminals70.0 mm2, m8, aluminium tube terminals95 .0 mm2, m10, pin terminal 1.5 mm2, pin terminal 2.5 mm2, aluminium in line connector25.0 mm2,, 35mm alluminium in line connector als-2"dowell", aluminium in line connector 70 mm2, 95 sqmm crimping alluminium type in-line connectors cat no: hai-15 hex make, crimping tools capacity: 10 mm2 to 185 mm2., crimping tools, capacity: 6 mm2 to 50 mm2., alluminum ring type lug 25 sq. mm, pvc saddle 10 mm, pvc saddle 15 mm, pvc saddle 20 mm, pvc saddle 32 mm, multistrend copper flexible wire 1 core x 4.0 mm2, (7 strendes) pvc (double) insulated, without armourr, 1.1kv grade (100m/coil)

Central Government/Public Sector

CTN :45713891 Due date: 20 Jul, 202620 Jul, 2026 20.00 Lacs
Tender For repair / maint of split acs 2/1.5 ton , windows acs 2 / 1.5 ton , voltage stablizers and connected items installed at command hospital (wc) and other various location in aor of age e/m ch - servicing of split type ac of capacity 2/ 1.5 tr after disconnecting all incoming and outgoing electric connection, water drain pipe line connection etc. and wash with approved chemical mixed water with the pressure pump, after servicing cleaned all the disturbed area and reassembling the water/electric connection and testing for entire satisfaction of engr-in-charge., all as per item no. 1 here-in-above but window type ac 2/1.5 tr capacity., supplying and charging of refrigerant gas r-22 only after vacuuming dehydration, leak testing of the system as per standard practice testing for proper cooling effects and satisfactory performance complete all as specified and as directed by engr-in-charge for room split/window type ac of capacity 2/1.5 tr., all as per item no: 3 above but gas r-32, all as per item no: 3 above but gas r-410a., all as per item no: 3 above but gas r-134a., taking out defective capacitor of capacity 50+6 mfd after disconnecting all incoming and outgoing electric connection including supply & fix new capacitor on same place and testing complete all as specified and as directed by engr-in-charge, all as per item no:7 here in above but of capacity 45+4 mfd ., all as per item no:7 here in above but of capacity 45 mfd ., all as per item no: 7 here in above but of capacity 6 mfd ., all as per item no: 7 here in above but of capacity 4 mfd ., supply & fixing as in replacement copper pipe 1/2" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 1/4" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 5/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 3/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply and fixing of insulation foam for copper pipe of size 1/2" after removing old one., supply and fixing of insulation foam for copper pipe of size 1/4" after removing old one., supply and fixing of insulation foam for copper pipe of size 5/8" after removing old one., supply and fixing of insulation foam for copper pipe of size 3/8" after removing old one., supply and fixing as in replacement of pvc flexible pipe 15 mm dia including any fittings as required complete inclusive of any type of leakage testing., all as per item no: 20 above but pipe of 20 mm dia., supply and fixing as in replacement of pvc water drain pipe 25 mm dia complete inclusive all fittings and any type of leakage testing., material and labour for sub main wiring with 2 x 2.5 sqmm +1 x 2.5 sqmm single core flame retardant pvc insulated unsheathed cable with stranded copper conductor drawn in and including heavy grade frlsh pvc concealed conduit isi marked with all accessories on walls and making good the disturbed surfaces including all conduits fittings, clamps guittes etc for earth dbs and boxes with proper thimbles all as directed by engr-in-charge. note :02 run of 2.5 sqmm , 01 run of 2.5 sqmm cable and 01 run of conduit shall be measured as one unit and paid accordingly., all as per item no: 23 here in above but of size 2x 4 sqmm +1x 4 sqmm., m&l cutting chases, pinning in stone concrete block or slab walls & making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring ,etc., and making good, cutting exc. 10 cm girth., supply and fix as in replacement of rigid non-metallic pvc conduit of size 20

Central Government/Public Sector

CTN :45726549 Due date: 20 Jul, 202620 Jul, 2026 NA
Tender For repairs maintenance of electrical and mechanical equipments high mast light search lights and other miscellaneous items at cad pulgaon - disconnecting and taking down existing unserviceable street lights/flood lights any type/watts from pole/wall and dismantling the light fittings. repairing/replacing unserviceable parts re-fixing the same on pole/wall after testing and removal of carbon from line jumpers/tightening of jumper/alignment of fitting defective street light/security light/flood lights fitting/led light from electric pole complete all as directed by eic. note: spare parts and accessories such as led driver, and connected items etc will be measured and paid separately under respective item as supply only and fixing is deemed to be included in this item., supply only led street light driver for 45 watts led street light as per make given all as specified and directed by eic., supply only led street light driver for 60 watts led street light/ flood light type as per make given all as specified and directed by eic., supply only led street light driver for 100 watts led street light/ flood light type as per make given all as specified and directed by eic., supply and fix in repair led streetlight of 45 watt comprises of pressure die cast aluminium housing & having system efficiency>123 lumens/watt i.e 5570 lumens,all leds should be highpower leds of 1w to 3w only with modular lens for batwing shape distribution of 30 degree & 60 degree,input voltage working range is 140 vac to 270 vac,brand name should be embossed,potted driver is used with 4kv internal & external 5kv potted surge protection,short circuit protection,open circuit protection,high & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,ip66 protected,thd10%,cri>70 cct 5700+/-300k,pf>0.9,driver efficiency>85%,lm79 report required from nabl accredited lab. including taking down old unserviceable fittings and bracket house must be adjustable or if required any cost of all fixing hardware shall be included in quoted rate complete all as specified and directed by eic note : 1. engraving of ca number on each lighting fitting (street light / flood light) shall be carried out by the contractor and the cost of the same shall be deemed to be included in the quoted rate. 2. no extra payment shall be made on this account. 3.the complete fitting along with led module, driver, surge protection device and all associated accessories shall be covered under 05 (five) years comprehensive warranty by the contractor from the date of invoice.make : philips/ wipro/crompton, supply and fix in repair led streetlight of 60 watt comprises of pressure die cast aluminium housing & having system efficiency>110 lumens/watt i.e 6670 lumens,all leds should be highpower leds of 1w to 3w only with modular lens for batwing shape distribution of 30 degree & 60 degree,input voltage working range is 140 vac to 270 vac,brand name should be embossed,potted driver is used with 4kv internal & external 5kv potted surge protection,short circuit protection,open circuit protection,high & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,ip66 protected,thd10%,cri>70 cct 5700+/-300k, pf>0.9, driver efficiency>85%,lm79 report required from nabl accredited lab. including taking down old unserviceable fittings and bracket house must be adjustable or if required any cost of all fixing hardware shall be included in quoted rate complete all as specified and directed by eic. note : 1. engraving of ca number on each lighting fitting (street light / flood light) shall be carried out by the contractor and the cost of the same shall be deemed to be included in the quoted rate. 2. no extra payment shall be made on this account.3. the complete fitting along with led module, driver, surge protection device and all as

corporations/Associations/Others

CTN :45721544 Due date: 04 Jul, 202604 Jul, 2026 1.70 Lacs
Tender For for the safety of kavand commuters, repair of 11 gw 33 gw electric power line and temporary barricading of transformers, repair of green wires and bent poles, and plastic insulation on iron poles for the safety of kawand passengers in the area of power distribution sub-division deobad ii (rural) under the power distribution division of devbud. work of installing ¼ glass cover sheet and reflected tape.

Central Government/Public Sector

CTN :45739165 Due date: 15 Jul, 202615 Jul, 2026 NA
Tender For supply of 2microgram sd 314 vials , rifampin 5microgram sd 128 vials , dalbavacin 30microgram em 155 vials , oritavancin 30microgram em 156 vials , telavancin 30microgram em 161 vials , pifampin 5microgram sd 128 vials , streptomycin sd 031 vials , fosfomycin 30microgram sd 179 vials , aztreonam 30microgram sd 212 vials , cefiderocol 30microgram sd 389 vials , ceftazidime avibactam 30 20microgram sd 309 vials , imipenem relevactan 10 25microgram sd 392 vials , meropenem vaborbactam 20 10microgram sd 334 vials , plazomicin 30microgram em 144 vials , sulbactam 10microgram em131 10st vials , colistin 10microgram sd 009 vials , polymyxin b 300 units sd 139 vials , gentamycin 120microgram hlg sd 016 vials , optochin dd 009 vials , novobiocin sd 053 vials , oxidase reagent disc dd 018 vials , bacitracin b sd 003 vials , bhi supplemented lq004 10 multiple 20ml packs , bhi supplemented lq004al 10 20ml packs , bhi broth media m210 500g packs , ecg machine , bmw covers assorted , washing powder 5 kg , recharble with battery aaa , ultra sound sony paper , ecg roll 210mm , door locks 5 liver , led tube lights 20w , street lights 20 w , machin sheet autoclavble 10 mtr , blood gruoping kit abd tulips , anti h tulips , anti a1 tulips , serum bovine albumin tulips , ahg tulips , bio medical bins 30 ltr yellow , bio medical bins 30 ltr red , bio medical bins 30 ltr blue , bio medical bins 30 ltr green , bio medical bins 30 ltr black , plastic bucket 20 ltr , plastic bucket 5 ltr , plastic mucks 1point5 ltr , grinder 10 ltr , mixture 1500 w , kellys pad , o2 flow meter with humidifier , ups distil water , vessels 20 ltr , ot slippers , formalin 37 percentage 500ml , 15 amp power sockets , 15 amp switch , 10 amp switch , 10 amp socket , led panel light 2x2 , led panel light1x1 , 32amp dp switch , fan capacitor , fan regulator , cc tv adaptor 1point5 amp , pillar cock , angle cock , health faucet , wall cock , wall mixture 3in1 , urinal flush tap , trap 3 inch , white cement , costing soda , mseal , gum 100 ml , tape , tissue roll , pluse oxymeter , tolet cleaner 5ltr , exaust fan , toilet cleaning acid , surgical sprit , spo2 probe , ecg probe , ppointmpointo line , 50ml syringe , ecg rolls210mm , nst paper , romavac suction drainnopoint14 , romavac suction drainnopoint12 , romavac suction drainnopoint16 , baciloid solution5 litre , dosiflow , injpoint calcium gluconate , closed ventilator circuitpaed , closed ventilator circuitadult , anchor suction tubes , cautery pencil , surgical spirit , dynaplast , isoflurane , cevoflurane , adk drain kitnopoint6 nopoint8 nopoint10 , abgel , botroclot , surgical mops , disposable mops , surgical drape kit , injpoint loxicard0point04 , savlon , sterile cup , flexamatic et tube5 5point5 6 6point5 , dispo cautery plate , cultural swab stick , formaldehyde slabs , injpoint fentanyl , injpoint bupronorpine300mg , suction catheter16 , injpoint dexmedetomidine , glycine3l can 1point5 percentage , normal saline3l can , terumo guide wire0point032 , terumo guide wire0point025 , tur loop22f double item , amplatz sheath21f , electric pressure washer1300w motor 110 pressure , electric blower650w motor multi nozzle attachments ampicillin 10microgram amp sd 002 vials, cefazolin 30microgram cz sd 047 vials, cefotaxime 10microgram ctx sd 040a vials, ceftriaxone 10microgram ctr sd 109 //bid details 2 / 109

corporations/Associations/Others

CTN :45702242 Due date: 07 Jul, 202607 Jul, 2026 17.03 Lacs
Tender For regular operation and maintenance of street lights (with material) at all industrial areas under riico ranpur kota(for 2 years) - regular operation and maintenance of high mast light in ranpur , kota including supply and replacing the required material and labour etc. complete as per the following terms and conditions:- i at any moment a minimum of 90% of total fixture must be in order. the defective fixture must be repaired within 3 days, falling which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate (accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor ). ii contractor shall arrange at his cost for put on & off the street light fixture at appropriate time regularly as per instructions of engineer-in charge. a register shall be maintained at riico/association office and complaint lodged must be attended by contractor within 24 hours. the person deputed by contractor shall attend the riico/association office daily and comply the instructions and attend complaints regularly. iii contractor will have to employ trained and qualified electricians for the work. iv corporation shall not be responsible for any kind of accident during execution of work. v contractor will be responsible for safety and security of fixtures and all concerned materials. vi contractor will be responsible for arrangement of all t&p required for the work vii cost of all labour and material like lamp / balllast wire etc. will be born by contractor. all material required for the work shall not be below the category-ii of concerned bsr item. contractor has to repair and maintenance of fixture with material in all cases like short circuit, phase to phase of jvvnl line etc. viii no extra payment will be made for fixing/removal of extra/existing fixture in the industrial area. ix contractor will be responsible for timely collection and deposition of electric bills of areas in each month. in case of delay in payment and jvvnl impose surcharge for delay payment the same will be recovered from the running bill fo the contractor. payment of electricity bill will be made by riico. x contractor will be responsible for rebate of timer provided by jvvnl. hence contractor will maintain the on/off system by timer properly. in case no rebate is provided by jvvnl due to failure of timer then rebate will be deducted from contractor payment. xi contractor will be responsible for any theft of electricity through poles and he will make necessary arrangements for this. in case of any theft is found suitable penalty will be imposed on the contractor. xii contractor will maintain cubical panel board and assessories fitted in it. in case of any fault repair/replace of material will be done by the contractor at his own cost. no extra payment will be made on behalf of material. xiii contractor has to keep ready total fixtures. in case of fault of fixture a penalty of rs.100/- per fixture per day will be imposed on the contractor., regular operation and maintenance of street light fixtures hpsv/ hpmv (70w/150w) in ranpur, kota including supply and replacing the required material and labour etc. complete as per the following terms and conditions:- i at any moment a minimum of 90% of total fixture must be in order. the defective fixture must be repaired within 3 days, falling which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate (accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor ). ii contractor shall arrange at his cost for put on & off the street light fixture at appropriate time regularly as per instructions of engineer-in charge. a register sh

CTN :45722569 Due date: 20 Jul, 202620 Jul, 2026 NA
Tender For supply of electric ceiling fan (v4) isi marked to is 374 , stationary storage type electric water heaters (geyser) (v3) isi marked to is 2082 , automatic line voltage correctors (step type) for domestic use (stabilizer) conforming to is 8448 , propeller type ac ventilating fans (exhaust fan) (v3) conforming to is 2312 , exhaust fan pvc body 12" (300mm) sweep 230v, 50 hz , desert cooler bode size 48 inch (hight) , made from gi sheet
 Loading, Please wait...

Connect us via What's Up