Web Analytics Made Easy - StatCounter

Transmission Line Spacer Tenders

Get complete information related to latest Transmission Line Spacer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Transmission Line Spacer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Transmission Line Spacer Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :41309943 Due date: 02 Sep, 202502 Sep, 2025 2.06 Crore
Tender For providing electrical infrastructure to the regularized ip sets by extending 11 kv lines, erection of 25 kva star 1 (4 star) rated distribution transformers and extension of lt line on partial turnkey basis (major materials will be supplied by bescom) under item wise fixed price contract on percentage quoting basis in channapatna rsd sub-division of ramanagara division, bescom

Central Government/Public Sector

CTN :41288981 Due date: 23 Aug, 202523 Aug, 2025 NA
Tender For tender for electrical works and distribution of ups supply for various locations in cil lab iit dharwad

State Government

CTN :41287257 Due date: 07 Aug, 202507 Aug, 2025 36.43 Lacs
Tender For routine operation and maintenance of existing l.t main control panel distribution panel feeder panel including electrical maintenance of all the existing nr buildings at marine dockyard i and ii under dss at svp during 25-26.labour component only

State Government

CTN :41287258 Due date: 07 Aug, 202507 Aug, 2025 29.76 Lacs
Tender For routine operation and maintenance of existing l.t main control panel / distribution panel / feeder panel including electrical maintenance of all the existing nr buildings at dss office complex, mc under dss at svp during 25-26. labour component only

State Government

CTN :41307944 Due date: 05 Aug, 202505 Aug, 2025 84.7 Thousand
Tender For general-urgent replacement of damaged distribution board and allied maintenance works in pwd roads subdivision office, neyyattinkara, tvpm.-electrical maintenance-general electrical work

corporations/Associations/Others

CTN :41309801 Due date: 11 Aug, 202511 Aug, 2025 1.66 Crore
Tender For operation and maintenance of sankh tank filling head works and raising main/distribution system/ including electrical system substation & pump house system with all men and material for a period of up to march 2027

corporations/Associations/Others

CTN :41284468 Due date: 19 Aug, 202519 Aug, 2025 4.97 Lacs
Tender For installation of electrical wiring and all accessoriess for urban health and wellness center at 400 rabindra sarani , kol-06 in ward no-18 under br-ii. - wiring with pvc insulated & unsheathed single core strandedcopper wire `fr ... in pvc casing-capping (precision make) onwall/ceiling.distribution wiring in 1.1 kv grade 2x22/0.3 (1.5 sqmm)single core stranded fr pvc insulated & unsheathed copper wire(brand(approved by eic) in suitable size pvc casing-capping(precision make) with 1x22/0.3 (1.5 sqmm) single core stranded frpvc insulated & unsheathed copper wire for ecc, incl. necy. pvcclips, fittings etc. to light/fan/call bell point with piano key type switch(anchor make) fixed on sheet steel fabricated switch board withperspex/bakelite top cover on wall incl. necy. connections andmaking earthing attachment and mending good damages to buildingworks. [pvc casing-capping and switch board both on surface)average run 6 mtr, concealed wiring with pvc insulated and sheathed wires inpolythene pipes - laying & fixing polythenepipe, ms boxes,switches etc.supply & fixing 240 v, 6a, plug socket with separate 6a piano key type switch (brand(approved by eic) on sheet metalswitch board embedded in wall incl. s & f 150x100x65mm ms(16swg) switch board and bakelite/perspex top cover of 3mm thickby brass screws after making housing for switch by cuttingbakelite/perspex cover and making necessary connections as required., concealed wiring with pvc insulated and sheathed wires inpolythene pipes - laying & fixing polythenepipe, ms boxes,switches etc.supply & fixing 240 v, 20a, plug socket with separate20 a piano key type switch (brand(approved by eic) on sheet metalswitch board embedded in wall incl. s & f 150x100x65mm ms(16swg) switch board and bakelite/perspex top cover of 3mm thickby brass screws after making housing for switch by cuttingbakelite/perspex cover and making necessary connections asrequired, concealed wiring with pvc insulated and sheathed wires inpolythene pipes - laying & fixing polythenepipe, ms boxes,switches etc.supply & fixing 240 v, 4 nos. 6a, plug socket withseparate 4 nos. 6 a piano key type switch, indicator & 16a switchtype sp mcb (brand(approved by eic) on sheet metal switch boardembedded in wall incl. s & f 240x200x65mm ms (16swg) switchboard and bakelite/perspex top cover of 3mm thick by brass screwsafter making housing for switch by cutting bakelite/perspex coverand making necessary connections as required, wiring with pvc insulated & unsheathed single core strandedcopper wire `fr ... in pvc casing-capping (precision make) onwall/ceiling.wiring in 1.1 kv grade single core stranded fr pvcinsulated & unsheathed copper wire (brand(approved by eic) offollowing sizes in 25mm pvc casing-capping (precision make) incl.necy. pvc clips, fittings etc. 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5sqmm), wiring with pvc insulated & unsheathed single core strandedcopper wire `fr ... in pvc casing-capping (precision make) onwall/ceiling.wiring in 1.1 kv grade single core stranded fr pvcinsulated & unsheathed copper wire (brand(approved by eic) offollowing sizes in 25mm pvc casing-capping (precision make) incl.necy. pvc clips, fittings etc. 2 x 56/0.3 (4 sqmm) + 1 x 22/0.3 (1.5sqmm), supplying and fixing double-door spn mcb distribution board withip-42/43 protection, concealed in wall after cutting the wall & mendinggood the damages to original finish incl. inter connection with suitablesize of copper wire and neutral link & provision for earthingattachment .legrand 2+8 way enclosure (607711), supplying and fixing 240/415 v mcb of breaking capacity 10ka & ccharacteristics on din rail of existing dbs and necessary connectionhavells 40a dp, supplying and fixing 240/415 v mcb of breaking capacity 10ka & ccharacteristics on din rail of existing dbs and necessary connectionlegrand 6-32 a sp, supplying and fixing double door vertical tpn mcb distributionboard for

CTN :41149770 Due date: 04 Aug, 202504 Aug, 2025 NA
Tender For bid to ras supply of electrical plugs (v2) isi marked to is 1293 (q2) , non - modular piano type domestic electrical switches as per is 3854 (q3) , piano type non modular electrical switch socket combination as per is 3854 and is 1293 (q3) , pressure sensitive adhesive plasticized pvc tapes with nonthermosetting adhesive as per is 7809 (part 3 / section 1) (q3) , piano type non modular domestic fan regulator as per is 11037 (q3) , ceiling rose - is 371 (q3) , fixed capacitors (fixed capacitor for single phase ac electric fan) as per is 1709:1984 (q3) , piano type non modular domestic electrical sockets - is 1293 (q3) , modular piano type domestic electrical switches as per is 3854 (q3) , modular electrical enclosure switch board boxes for modular type accessories (q3) , miniature circuit breakers distribution boards as per is 13032 (q3)

CTN :41299213 Due date: 11 Aug, 202511 Aug, 2025 NA
Tender For supply of non - modular piano type domestic electrical switches as per is 3854 (q3) , piano type non modular domestic electrical sockets - is 1293 (q3) , isolator switch (q3) , plug and socket distribution board (q3) , electrical plugs (v2) isi marked to is 1293 (q2) , heating element (bhel) (q3) , pvc flat cable, aluminium conductor with pvc insulation and sheath as per is 694 (q3) , fixed capacitors (fixed capacitor for single phase ac electric fan) as per is 1709:1984 (q3)

CTN :41287395 Due date: 08 Aug, 202508 Aug, 2025 6.06 Lacs
Tender For replacement of electrical accessories, ceiling fan and tube lights in inspection bungalow building, sector 19 chandigarh. - dsr item no. 1.10 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required., group c, dsr item no. 1.15 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm. frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /pvc conduit including dismantling as required., group c, dsr item no. 1.21 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required., 20 mm, 25 mm, dsr item no 1.17 supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required., 3 x 1.5 sq. mm, 3 x 2.5 sq. mm, dsr item no.1.24 supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required., 5/6 a switch, 3 pin 5/6 a socket outlet, dsr item no.1.25 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required., dsr item no.1.26 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required., dsr item no.1.27 supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc. as required., 1 or 2 module (75 mmx75 mm), 3 module (100 mmx75 mm), 4 module (125 mmx75 mm), 6 module (200 mmx75 mm), 8 module (125 mmx125 mm), 12 module (200 mmx150 mm), dsr item no.1.31 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 a modular socket outlet and 5/6 a modular switch, connections etc. as required., dsr item no.1.32 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 a & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required., dsr item no.1.57 supplying & fixing suitable size gi box with modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, "c" curve including connections, painting etc. as required., dsr item no. 2.10 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, "c" curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required., single pole, dsr item no.2.5 supplying and fixing of following ways surface/ recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs (but without mcbs and incomer) as required (note: vertical type mcb tpdb is normally used where 3 phase outlets are required)., 8 way (4 + 24), double door, s/i/t/c of 1x18/20watt. led box type fittings made of crca sheet with 1 nos. led tube rods. the fittings should be installed on existing surface. the led tube rod should be of philips/ wipro/ havells/ bajaj/ crompton/ trilux/ panasonic/ lt/ jaquar/ surya make of polycarbonate material only. (as per complete item no. 14 of the dnit)., s/i/t/c o
 Loading, Please wait...

Connect us via What's Up