Get complete information related to latest Transport Ventilator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Transport Ventilator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Transport Ventilator Tenders.
Tender For providing of customized amc/cmc for pre-owned products - transportventilator make resmed; astral 100; annual maintenance contract (amc); quarterly; no
Tender For supply of group tender for hospital equipment for various department[ turnkey basis] - endoscope set , pure tone audiometer , videonystagmographic machine (vng) , oae screener , basic ent examination units with motorized patient chairs and microscope , mobile booth for audiometry , ent opd examination set , assorted diagnostic set for ent , b.p. apparatus , weighing machine adult , stethoscope , ophthalmoscope , led x ray view box , spirometer , multipara patient monitor , vital sign monitor , defibrillator with ecg monitor , pulse oximeter , syringe infusion pump , volumetric infusion pump , ventilator-high end , transportventilator , transport monitor , laryngoscope , ambu bag , 12 channel ecg machine , tmt machine (stress test system) , ambulatory bp monitor , holter system with work station etc...
Tender For procurement of medical consumables items for use by the department of cardiovascular and thoracic surgery, goa medical college - adult membrane oxygenator with hard shell reservoir 1. should have heparin free, hydrophilic polymer surface balance coating. 2. should have open circuit configuration 3. should have hard shell venous reservoir of capacity more than 4000ml. with built of cardiotomy reservoir with 30m filter capacity.4. should have blood flow range 0.5 ltr to 7 ltr/min.5. should have priming volume less than 200ml6. should have high efficiency heat exchanger positioned in post pump configuration.7. venous return port 1/2" with rotating facility.8. should have an auto vent facility.9. port size : arterial outlet, venous outlet 3/8" venous inlet 1/2" membrane surface area 1.8 to 2.5m210. should have sampling port.11. us fda and ce approval is required., adult membrane oxygenator with hard shell reservoir with integrated arterial filter 1. should have heparin free, hydrophilic polymer surface balance coating. 2. should have open circuit configuration 3. should have hard shell venous reservoir of capacity more than 4000ml. with built of cardiotomy reservoir with 30m filter capacity.4. should have blood flow range 0.5 ltr to 7 ltr/min.5. should have priming volume less than 200ml6. should have high efficiency heat exchanger positioned in post pump configuration.7. venous return port 1/2" with rotating facility.8. should have an auto vent facility.9. port size : arterial outlet, venous outlet 3/8" venous inlet 1/2" membrane surface area 1.8 to 2.5m210. should have sampling port.11. us fda and ce approval is required., small adult membrane oxygenator with hard shell reservoir 1. should have a micro porous hollow fiber membrane oxygenator 2. should have open circuit configuration 3. should have hard shell venous reservoir of capacity more than 3500ml. with built of cardiotomy reservoir with 30m filter capacity.4. should have blood flow range 0.5 ltr to 4 ltr/min.5. should have priming volume less than 200ml6. should have high efficiency heat exchanger positioned in post pump configuration.7. venous return port 1/2" with rotating facility.8. should have an auto vent facility.9. port size : arterial outlet, venous outlet 3/8" venous inlet 3/8" 10. should have sampling port.11. us fda and ce approval is required., small adult membrane oxygenator with hard shell reservoir with integrated arterial filter 1. should have a micro porous hollow fiber membrane oxygenator with integrated arterial filter2. should have open circuit configuration 3. should have hard shell venous reservoir of capacity more than 3500ml. with built of cardiotomy reservoir with 30m filter capacity.4. should have blood flow range 0.5 ltr to 4 ltr/min.5. should have priming volume less than 200ml6. should have high efficiency heat exchanger positioned in post pump configuration.7. venous return port 1/2" with rotating facility.8. should have an auto vent facility.9. port size : arterial outlet, venous outlet 3/8" venous inlet 3/8" 10. should have sampling port.11. us fda and ce approval is required., paediatric membrane oxygenator with hard shell reservoir 1. should have a micro porous hollow fiber membrane oxygenator 2. should have open circuit configuration 3. should have hard shell venous reservoir of capacity more than 3500ml. with built of cardiotomy reservoir with 30m filter capacity.4. should have blood flow range 0.5 ltr to 3.5ltr/min.5. should have priming volume less than 140ml6. should have high efficiency heat exchanger position in post pump configuration.7. venous return port 3/8" with rotating facility and reducers8. should have an auto vent facility.9. pot size : arterial outlet, venous outlet 3/8" venous inlet 3/8" with reducers10. us fda and ce approval is required., paediatric membrane oxygenator with hard shell reservoir with integrated arterial filter 1. should have a micro porous hollow fiber membrane oxygenator with integrated arterial filt
Tender For supply of oxygenator various type-, adult membrane oxygenator with in 2.5 sqm, recommended blood flow upto 8 lpm, with hardshell reservoir, biocompatible coating and integrated arterial line filter, adult membrane oxygenator with membrane surface area 1.4 metre square, a maximum of blood flow rate 6 lpm, hardshell reservoir with 4.5 litres capacity, biocompatible coating and integrated arterial line filter., paediatric membrane oxygenator with membrane surface area of approx????? 1.5 metre square, blood flow ranging 0.5-4l/min, hardshell reservoir, maximum blood storage capacity 3000ml, oxygenator with biocompatible coating and integrated arterial line filter, infant/paediatric membrane oxygenator having membrane suface area ranges 0.60 to 1.0 square metre, blood flow ranges 0.5 to 3.0 lpm intregrated hardshell reservoir, oxygenator with biocompatible coating and integrated arterial line filter neonate / infant membrane oxygenator with effective, membrane surface area of 0.5 square meter, recommended blood flow upto 1.5 lpm, coated membrane, oxygenator with biocompatible coating and integrated arterial line filter and a hardshell reservoir