Web Analytics Made Easy - StatCounter

Tray Trolley Tenders

Get complete information related to latest Tray Trolley Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Tray Trolley Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Tray Trolley Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :40126145 Due date: 05 May, 202505 May, 2025 2.62 Lacs
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s

corporations/Associations/Others

CTN :40126147 Due date: 05 May, 202505 May, 2025 2.62 Lacs
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s

CTN :40141752 Due date: 28 Apr, 202528 Apr, 2025 NA
Tender For providing of repair and overhauling service - hydraulic refilling trolley; hydraulic refilling trolley; yes; buyer premises

CTN :40136135 Due date: 16 May, 202516 May, 2025 NA
Tender For supply of hydraulic refilling trolley

CTN :40122322 Due date: 30 Apr, 202530 Apr, 2025 NA
Tender For supply of conversion of 04 wheeler manual trolley into hydraulic pressure trolley capacity 10 ton detail as per attached scope of work. [ warranty period: 30 months after the date of delivery ]

Corporations And Associations And Others

CTN :40117872 Due date: 06 May, 202506 May, 2025 NA
Tender For tender for supply of spares for cane unloader trolley - supply of spares for cane un loader trolley make-kowa sales, hydraulic pump k3 vl-80 for cane un loader trolley sr. no. 00675198 , suction filter, return line filter, air breather filter

Central Government And Public Sector

CTN :40122255 Due date: 05 May, 202505 May, 2025 NA
Tender For supply of hydraulic trolley cum lifter for lhb. make: premier, khushi or span technical specification as per annexure-a [ warranty period: 30 months after the date of delivery ]

Central Government/Public Sector

CTN :39113951 Due date: 26 Apr, 202526 Apr, 2025 NA
Tender For bid to ras bid to ras corrigendum : supply of 2x660 mw talcher workshop equipment - vertical turret lathe machine , heavy duty lathe machine , medium duty lathe machine 1 , medium duty lathe machine 2 , universal milling machine , surface grinding machine , cylindrical grinding machine , slotting machine machine , radial drill machine , column drill machine , hydraulic press machine , plate bending machine , plate shearing machine , dynamic balancing , shaper machine , pipe bending machine , tool and cutter grinding machine , power hacksaw machine , welding generator , welding transformer machine , battery operated trolley , gas cutting and heating equipment , supervision of assembly, erection and commissioning -total lump sum prices for visits , supervision of assembly, erection and commissioning -total lump sum prices for supervision of assembly erection and commisioning etc.

Central Government/Public Sector

CTN :40097682 Due date: 03 May, 202503 May, 2025 NA
Tender For supply of spares for hydraulic trolley electrical operated , tank pressure generator assy , hydraulic trolley elc, operated - 3 ph

CTN :39643331 Due date: 02 May, 202502 May, 2025 NA
Tender For corrigendum : procurement of machinery and equipment on behalf of directorate of health services hp - cardiac monitor, high pressure high speed horizontal steam instrument sterilizer, phacoemulsification unit, fess endoscopy unit, ent operating microscope, oae(clinical), ent workstations /treatment unit, shaver system cum micro drill, digital mammography unit, analogue mammography machine, computed radiography system for mammography, electro hydraulic operation table for orthopaedic surgery, surgical instrument set (ortho), autopsy(mortuary)table, mortuary cabinet (6- body), laparoscopic set with instruments, ctg machine, delivery table(obstetric labour table), foetal doppler, multipara monitor (obg), video colposcope, suction apparatus, autoclave horizontal, autoclave vertical, autoclave ot automatic, multi-channel electrocardiographic, fogging machine for ot (fumigator), crash cart trolley, infusion pump, retinoscope, indirect ophthalmoscope, electric cautery, laryngo-laryngoscope, digital otoscope, head light(ent), power drill for ortho, power saw for ortho, harmonic scalpel, laparotomy set, single puncture laparoscope for tubal ligation, spot light, note :-1.the basic price of the goods to be quoted without gst.2.all the prices should be quoted in indian rupee (inr) only.3.the cmc should be quoted year wise without gst.4.cmc rate and turnkey work (if any) shall be included for determining l-1 bidder.5.gst shall be payable as applicable from time to time.6.charges towards packing & forwarding, inland transportation, insurance (local transportation and storage) would be borne by the supplier from warehouse to the consignee site, loading/unloading and other local costs incidental to delivery of the goods to their final destination as per section-i shall also be borne by the supplier.7.the price should be inclusive of supply, installation, commissioning charges.8.l-1 will be determined item-wise on total basic price of the equipment (all inclusive) (excluding gst) + total cmc (if any) (excluding gst) + turnkey work (if any) (excluding gst) for all the items as mentioned in section-i.9.in case of optional accessories/items (if any), rates may quoted in separate pdf file (along with the price bid), which will not be considered for determining l-1 bidder. it is reiterated that the bidder should not submit this in the technical bid.it is certified that the cost of goods shown above, is all inclusive except gst.signature of authorizedsignatory with seal
 Loading, Please wait...

Connect us via What's Up