Get complete information related to latest Trench Cover Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Trench Cover Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Trench Cover Repair Tenders.
Tender For corrigendum : repair to security lights panels dg sets fire alarm ups with covered items at af stn bikaner under ge (af) nal - excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m depth, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed by engineer-in-charge., removal of excavated material soils to a distance n exc 50 m and depositing where directed at a level not exceeding 1.5m above the startly point complete all as specified and directed., returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm as in any type of soil complete all as specified and directed., material and labour for sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed. note : punned thickness shall be measured for payment., material and labour for un-reinforced pre-cast concrete cable covers, class lv type-1, flat size 250mm x 150mm x 40mm thick complete all as specified and directed., taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 6 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 10 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 4 core, 16 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 25 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 35 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 50 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 6 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge , supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 10 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 4 core 16 sqmmlaid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 3.5 core 25 sqmm laid in trenches
Tender For supply of xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1),lighting pole or post and hardware - tubular street light poles (v2),material and labour,testing,installation,repair,repair,welding,excavating in trenches,returning filling in,removing excavated material,material and labour,supply and laying,m l for,supplying and fixing,ml for cement,ml for pcc,disconnecting taking out,material and labour,testing,installation,repair,installation,electrical work
Tender For planning, design, construction, testing and commissioning, certification, validation of biosafety level-3 (bsl-3) laboratory (g plus 1 floor) in epc mode-i under pm-abhim for national centre for disease control (ncdc) at kims, hubballi, karnataka inclusive of (i) obtaining of all local body approvals, eia, consultancy services (architectural, structural & mep), modular pre-fabricated wall panel & pre fabricated ceiling panel, epoxy flooring, doors, drains, water supply piping in bsl-2/3 lab containment area, sanitary installation, internal roads, parking facilitation, ug sump, terrace water tank, water supply lines, storm water drains, external sewerage system, service trenches, demolishing of existing structure, retaining walls, internal electrical installations, fire alarm system, fire fighting system, lifts, sub station, dg sets, ups, air conditioning system (hvac & vrv/vrf), cctv, access control system , ibms, lan, ip based epabx system, audio visual system, boom barriers,subwork/packages:etp equipment and street lighting etc., (ii) design, supply, installation, testing and commissioning of all equipment for bsl-3 & bsl-2 lab. (iii) certification, validation, commissioning of bsl-3 lab facility from third party validation agency. (iv) operation of complete facility for 5 years, annual maintenance during 3 years defect liability period plus 2 years comprehensive maintenance of complete bsl-3 lab facility including all equipment after 3 years dlp including annual validation
Tender For supply of supply, fabrication and construction of copper plate earthing details of electrodes and earth pit at akashvani jaspur, uttarakhand , providing of 50mm x 3mm copper strip and interconnecting earth electrodes with fabrication and fixing of 50mm x 3mm copper strip at akashvani jaspur, uttarakhand , providing and fixing of nomenclature sign marker for earth pits at akashvani jaspur, uttarakhand , providing of 25 mm x 3 mm copper strip for extension of earthing system up to the transmitter hall, ups and lt panel at akashvani jaspur, uttarakhand , copper strip laying for extension of earthing system up to the xtr hall, ups and lt panel and terminating in bus bar by digging the soil and placing the copper strip along the trenches at air jaspur , providing of 375x38x6mm copper bus bar with insulators and steel nut bolts and the fixing of 375x38x6mm copper bus bar is to be done to terminate the different earthing system at akashvani jaspur , making of trenches of size 700mm x 750mm for 185 sq mm 3.5 core starting from state electricity transformer to lt panel by digging the soil which includes cement concrete interlocking tiles , providing and grouting of 2 nos. of 4inch dia g.i. pipes of different length on the cement concrete flooring, road, and cement concrete interlocking tiles and along the vertical walls. , unwinding roll of 185 sq. mm 3.5core al. cable from their cable drum and laying the cable through the trenches and through the g.i. pipes as laid down at akashvani jaspur , reconstructing the cement concrete interlocking tiles floor and repairing the area with cement concrete interlocking tiles and finishing the surface at akashvani jaspur , providing and fixing of lt cable route marker made up of 2.5inch dia signage with 10mm x 2ft long ms rod from transformer to lt panel at akashvani jaspur , providing and fabricating of overhead shed for the installed 62.5kva dg set as per drawing at akashvani jaspur supply, fabrication and construction of copper plate earthing details of electrodes & earth pit as per given below: digging of pit of size: 1 mtr x 1 mtr x 3.5 mtr(d) providing of copper plate size 600 x 600 x 3mm. providing of copper strip of 50x3mm shall be extended from bottom of the earth pit to the surface of the earth pit, after joining the copper strip by copper rivets and proper brazing of strip to the copper plate. providing and fixing the 10ft. long 38 mm dia class c g.i pipe of reputed make such as surya, jindal or similar and fixing with the copper plate in the center with g.i/ ss nut bolts class c. one g.i. reducer at the top of the pipe is to be provided for fixing steel mesh for watering as shown in the drawing. placing the copper plate with pipe and strip into the pit. providing & filling of 2 nos. of bags of bentonite each of 50 kg. (for each earth pit.) providing & filling of 80kg charcoal, and 80kg raw salt in alternate 3 to 4 layers in each earth pit. the fresh soil about 2.0 cubic metre in earth pit size in layers is to be arrange to fill the pit for proper result. proper watering of the filled pit for initial charging of pits. providing of heavy duty c.i. cover with lifting hooks. construction of cc chamber in ratio 1:4:8 & fixing of heavy duty c.i. cover., providing of 50mm x 3mm copper strip and interconnecting earth electrodes with fabrication & fixing of 50mm x 3mm copper strip as per given below: i. 2 grid out of 6 pits for transmitter. ii. 1 grid out of 3 pits for audio. iii. power supply-3 pits separate (lt electrical panel, ups & isolation transformer, avr) iv. rf //bid details 2 / 25
Tender For repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and getting out in an
Tender For supply of aluminium fabricated toughened glass wall , false ceiling work , flooring with glazed vitrified tiles , excavation in trenches as required for column work , brick work , aluminium fabricated toughened glass door double leaf , led light for false ceiling , ac hot and cold split 2 ton , electrical work with switch and socket , jhummar
Tender For providing of facility management services - lumpsum based - repair and maintenance works at 33 11 kv sub stations cg city 1 to 6 and sector 7 total 07 nos) including roof repair painting trenchcoverrepair and toilet repair works; civil works; consumables to be ..
Tender For annual rate contract for supply and installation of electrical items and services at padc, panipat - electrical arc padc panipat 1st year, excavation of earth for cable / pipe laying for electrical work excavation of earth for cable trenches / laying of g.i. pipes for cable work in all types of soils including saturated soil upto a max. depth of 1.5 metres including shoring, strutting and bailing out of water (if necessary), backfilling and compacting in layers not exceeding 20 cm. thick to the finished ground level and disposal and dressing of excess earth within a lead of 50 metres all complete with labour and materials as per standards, drawings, specifications and directions of engineer-in-charge., 200 mm x 25 mm x 2 mm, supplying and fixing of gi route marker suppplying cable route marker with 10 cm x 10 cm x 5 mm thick gi plate with inscription thereon, bolted/ welded to 35 mm x 35 mm x 6 mm angle iron, 60cm long and fixing the same in ground as required. job includes painting with one coat of redoxide and finishing paint., 3 / 3.5 / 4 x 25 sqmm, 3 / 3.5 / 4 x 50 sqmm, 1.5 sqmm, 2.5 sqmm, 4 sqmm, 6 sqmm, 10 sqmm, 16 sqmm, 20 sqmm, 25 sqmm, 35 sqmm, 16 sqmm, 25 sqmm, 35 sqmm, 50 sqmm, 10.0 to 16.0 mm, 16 sq. mm, 65 mm dia 3 metre long, 25 x 5 mm gi strip, 64 kg charcoal and 5 kg salt, 100 amps., 63 a tpn 4 way, 5 to 32 amp, 40 amp, double pole, triple pole, triple pole and netural, four pole, 16 amps., 30 ma, 63 amps., 30 ma, 63 amps., 30 ma, 10 a spn. mcb industrial socket outlet supplying and fixing 10 amps., 240volts, spn industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 10 amps. c curve, sp,mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required. note: isi marked sockets shall be used., 20 a spn. mcb industrial socket outlet supplying and fixing 20 amps., 240volts, spn industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps, c curve, sp,mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required. note: isi marked sockets shall be used., 20 a tpn mcb industrial socket outlet supplying and fixing 20 amps., tpn, industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 amps, c curve, tp mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required. note: isi marked sockets shall be used., 2 + 4 way, provide shock hazard chart supply and installation of shock hazard chart as per ie rules 1956 (clause-44) complete with frame and glass including necessary clamps, bolts, rawl plugs, etc. breachking and making good the wall if required. all complete with labour and materials as per the direction of engineer-in-charge., provide caution board at sub-station supply and installation of "caution boards" mv-200 mm x 150 mm / hv- 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.at sub-stations as per is2551/upto date including supply of necessary clamps, nuts, bolts and other hardware. all complete with labour and materials as per the direction of the engineer-in-charge, upto 5.5kw, plug- 2 pole+ earth, 250v- 20 amp, plug- 3 pole+ earth, 440v- 20 amp, red / yellow / amber / green / milky white leds, blue led, 1 way 5 / 6 amps. piano type switch with isi mark, 1 way 15 / 16 amps. piano type switch with isi mark, 2 pins 5 / 6 amps. penta flush socket outlet, 3 pins 5 / 6 amps. penta flush socket outlet, piano type 5 pins 5 / 6 amps. socket outlet, 3 pins flush type 15 / 16 amps. socket outlet, flush type 6 pins 6 / 16 amps. uni. socket outlet with isi mark,
Tender For supply of electrical item c c - bore bent to shape as required at site , supply and fixing of sub main wiring with three core 1.5 sqmm multi stranded copper conductor pvc insulated unsheathed frls cable 1100 volts grade , supply and fixing of solar street light fitting 12 watt having high efficiency mono crystalline solar pv module, lithium ferro phosphate battery with in-built bms technology, high efficacy led , supply and fixing of solar street light fitting 16 watt having high efficiency mono crystalline solar pv module, lithium ferro phosphate battery with in-built bms technology, high efficacy led , supply and fixing of solar street light fitting 20 watt having high efficiency mono crystalline solar pv module, lithium ferro phosphate battery with in-built bms technology, high efficacy led , supply and errection in replacement of steel tubular swaged pole 8.5 m long type 410-sp-22 complete with cl base plate , m and l for pcc 1-3-6 type c2 using 40mm graded aggregate crushed stone aggregate as in pole foundation, filling and mass concrete complete all as specified and directed. , m and l for plain cement concrete 1-2-4 type b1 using 20mm graded stone aggregate , supply of paint and painting of steel pole swan neck type or straight type up to 9 mtr height with two coat of aluminium paint after scratching out old paint , supply, erect and commissioning of high galvanized mast light of height 15 mtr, suitable for 6 to 9 lantern symmetrically fitted along with their control gear , m and l for boring of horizontal hole under road, pavement, hardstanding suitable for passing through upto 50mm bore complete all specified and directed. , replacement of unserviceable wire by cable from junction box to light fitting fixed on pole on existing pvc conduit by pvc insulated unsheathed copper conductor frls of 1.5 sqmm three core. , supply of laying and digging excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc , returning filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified and as directed , supply of digging and laying removal of excavated material by surplus soil to a distance n exc 50m and depositing where directed at a level n exc 50m above the starting point , supply and laying sand in trenches for protection of cable, sand cushioning to cable 8 cm thick below cable and 15 cm thick above cable in layers complete all as specified and as directed , supply and lay fly ash bricks best quality, laid in trenches, perpendicular to ug cable for cable protection complete all as specified and directed , laying only old bricks obtained from item no 13 perpandicular to ug cable for cable protection complete all as specified and directed. //bid details 2 / 35
Tender For "one time cleaning of electrical cable trenches of various shops (i.e.las, lfs, ecs, abs, lts, lps, bogie shop-1&2, hms, tms, coil shop, lms, tool room and hts) in workshop area, plw/patiala.