Web Analytics Made Easy - StatCounter

Tridazole Tab Tenders

Get complete information related to latest Tridazole Tab Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Tridazole Tab Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Tridazole Tab Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45524795 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For e-tender for rate contract for supply of lifesaving permanent implant product (item), for lifesaving cardiac operations and cardiac procedures (adult, paediatric & neonatal) i.e. coronary stent for u n mehta institute of cardiology and research centre (affiliated to b. j. medical college & nabh accredited) ahmedabad, gujarat, india. - bare metal stent - cobalt chromium, 1, all sizes, bare metal stent - cobalt chromium, 1, all sizes, sirolimus coated drug eluting stent with durable polymer - cobalt chromium, 1, all sizes, sirolimus coated drug eluting polymer-free coronary stent system, 1, all sizes, sirolimus coated drug eluting polymer-free coronary stent system, 1, all sizes, everolimus coated drug eluting stent with durable polymer - cobalt chromium, 1, all sizes, everolimus coated drug eluting stent with durable polymer - cobalt chromium, 1, all sizes, everolimus coated drug eluting stent with durable polymer - cobalt chromium, 1, all sizes, everolimus coated drug eluting stent with durable polymer - cobalt chromium, 1, all sizes, everolimus coated drug eluting stent with durable polymer - platinum chromium, 1, all sizes, everolimus coated drug eluting stent with durable polymer - platinum chromium, 1, all sizes, everolimus coated drug eluting stent with bioabsorbable polymer - platinum chromium base, 1, all sizes, everolimus coated drug eluting stent with bioabsorbable polymer - platinum chromium base, 1, all sizes, everolimus coated drug eluting stent with bioabsorbable polymer - platinum chromium base, 1, all sizes, zotarolimus coated drug eluting stent with durable polymer - cobalt chromium base, 1, all sizes, zotarolimus coated drug eluting stent with durable polymer - platinum iridium/cobalt chromium base, 1, all sizes, zotarolimus coated drug eluting stent with durable polymer - platinum iridium/cobalt chromium base, 1, all sizes, sirolimus coated drug eluting stent with bioabsorbable polymer, 1, all sizes, sirolimus coated drug eluting stent with bioabsorbable polymer, 1, diameter: 2.5 to 6 mm,length: 12 to 30 mm, coronary balloon mounted covered stent (monorail) - sandwich stent design, 1, diameter: 2.5 to 6 mm,length: 12 to 30 mm, coronary balloon mounted covered stent (monorail) - single stent design, 1, diameter: 2.5 to 6 mm,length: 12 to 30 mm, coronary balloon mounted covered stent (monorail) - single stent design, 1, all sizes, sirolimus eluting bioresorbable vascular scaffold system, 1, all sizes, bare metal stent - cobalt chromium, 1, all sizes, bare metal stent - cobalt chromium, 1, all sizes, sirolimus coated drug eluting stent with durable polymer - cobalt chromium, 1, all sizes, sirolimus coated drug eluting polymer-free coronary stent system, 1, all sizes, sirolimus coated drug eluting polymer-free coronary stent system, 1, all sizes, everolimus coated drug eluting stent with durable polymer - cobalt chromium, 1, all sizes, everolimus coated drug eluting stent with durable polymer - cobalt chromium, 1, all sizes, everolimus coated drug eluting stent with durable polymer - cobalt chromium, 1, all sizes, everolimus coated drug eluting stent with durable polymer - cobalt chromium, 1, all sizes, everolimus coated drug eluting stent with durable polymer - platinum chromium, 1, all sizes, everolimus coated drug eluting stent with durable polymer - platinum chromium, 1, all sizes, everolimus coated drug eluting stent with bioabsorbable polymer - platinum chromium base, 1, all sizes, everolimus coated drug eluting stent with bioabsorbable polymer - platinum chromium base, 1, all sizes, everolimus coated drug eluting stent with bioabsorbable polymer - platinum chromium base, 1, all sizes, zotarolimus coated drug eluting stent with durable polymer - cobalt chromium base, 1, all sizes, zotarolimus coated drug eluting stent with durable polymer - platinum iridium/cobalt chromium base, 1, all sizes, zotarolimus coated drug eluting stent with durable polymer - platinum iridium/cobalt chromium base, 1, all s

CTN :45513508 Due date: 22 Jun, 202622 Jun, 2026 80.3 Thousand
Tender For usfda/dgci approved third generation sirolimus eluting des, cocr platform, biodegradable polymer hyb

Central Government/Public Sector

CTN :45472857 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For supply of drug coated ptca balloon (sirolimus). diamter minimum 1.5 mm to 4 mm with length 10 mm to 40 mm. (all different sizes must be available with the firm and will be asked as when required) ]

Central Government / Public Sector

CTN :45436571 Due date: 16 Jun, 202616 Jun, 2026 NA
Tender For hq_med_sur_zrc_zonal rate contract for supply of ph:.(153047) biodegradable polymer sirolimus eluting coronary stent with stainless - steel platform having microporous surface, albuminal coating and shellac resin with diameters of 2.0 mm to 4.0 mm of varying length ]

CTN :45448490 Due date: 19 Jun, 202619 Jun, 2026 NA
Tender For supply of everolimus drug eluting platinum chromium coronary stent assorted sizes , bis approved zotarolimus drug eluting stent with core wire technology platinum iradium core and continous sinosold technology c , everolimus eluting drug eluting stents on cobalt chromium platform with ultra low strut thickness up to 50 aum fda ce dcgi approved , sirolimus eluting cobalt chromium coronary stent system with ultra thin struts 60microns across all diameter and length with a biodegredable p , usfda pmda approved drug eluting stents consists of cocr platform with bio inspired stent design bio degradable polymer pdlla pcl and serolimus

CTN :45407687 Due date: 23 Jun, 202623 Jun, 2026 3.47 Crore
Tender For supply of biodegradable polymer coated cobalt chromium sirolimus drug eluting stent system with ultrathin 60 m , everolimus eluting cobalt chromium 4 th generation drug eluting stent coronary stent assorted sizes , everolimus eluting platinum chromium 4 th generation drug eluting stent coronary stent assorted size

Central Government/Public Sector

CTN :45405728 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For supply of tab sirolimus 1 mg (irp_no - 02345 as per drg.no. 2345.0 ]

Central Government/Public Sector

CTN :45335075 Due date: 05 Jun, 202605 Jun, 2026 NA
Tender For srphc82281240-coronary drug eluting stents with (1) stent on cobalt chromium alloy or platinum chromium alloy. (2) stent with coating of polymer carrier for active drug ( sirolimus everolimus or zotarolimus shown to be effective in preventing neo-intimal hyperplasia) (3) stent diameter should be from 2.5mm to 4mm and length of the stent should be 12mm to 48mm. (4) the strut thickness should be 91 micron or less. (5) stent delivery system should be monorail (single operator exchange or rapidexchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi approval should be enclosed in the tender bid. (9) the long term efficacy and safety of the stent in terms of target vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals. (10) the documents related to the efficacy and safety of the stent should be only for the brand that is offered in the tender bid (11) the manufacturer/supplier should submit proof of supply of thestent to a major government institute. unit:no [ warranty period: 30 months after the date of delivery ] ]

Central Government / Public Sector

CTN :45339400 Due date: 08 Jun, 202608 Jun, 2026 NA
Tender For hq_med_sur_zrc_zonal rate contract for supply of ph:.(153045) sirolimus eluting stent cobalt - chromium stent with abluminal coating and specialised gradient coating (no polymer coating at joint & bends). bioresorbable polymer of plcl (poly lactic acid + poly caprolactone pcl) with degradation time of 3-4 months. low concentration of sirolimus (0.8ug/mm sq) should have bio-inspired open-cell. pmda approved ]

CTN :45283436 Due date: 03 Jun, 202603 Jun, 2026 NA
Tender For supply of polymer free sirolimus eluting coronary stent, with microporous surface, abluminal coating, shellac resin and 10 years of safety and efficacy data. warranty: replacement warranty against any manufacturing defect noted on the o.t. table. [ai(2026-27), item code-no: s-62284, sl no.2183] ]
 Loading, Please wait...

Connect us via What's Up