Get complete information related to latest Tube Fixture Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Tube Fixture Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Tube Fixture Tenders.
Tender For corrigendum : supply of kirloskar make pumps spares on door delivery basis at hbl plant sugauli, east champaran, bihar - supply of kirloskar make pumps spares at hbl plant sugauli as per the technical specification mentioned below:, bare pump model db 100/40 or ib 100/40xe,ci impeller, wearing plate de sp-4l make kirloskar, screw counter sunk m12 1.75 50 mm lft ss make kirloskar, nut hex head (ms) sp-4l m12 1.75, sewage dewatering submersible pumpmodel eterna 15000cw 4plpower rating 15 kw / 20 hpdelivery size 150 mmrated voltage 380 vspeed 1440 rpmmax solid handling size 45 mmhead range 6 m to 20 mflow 288 m /hr to 400 m /hrimpeller cidelivery casing cimotor body cipump shaft cspump make kirloskarsuitable cable for eterna 15000cw 4pl pump 30 m with star delta panel., self-priming pump coupled with ie2 motor, starter, and cablemodel sp4l + with 12.5c4 motor power rating 9.3 kw / 12.5 hpsuction 100 mmdelivery 100 mmrated voltage 415 vspeed 1450 rpmimpeller dia 292 mmhead range 10 m to 26 mflow range 41 lps to 16 lpsmaterial of construction (moc):impeller cidelivery casing cimotor body cishaft c40sealing gland packingpump make kirloskarstar delta panel for sp4l pumpsuitable cable for sp4l pump 30 m.
Tender For bid to ras supply of flood light led fixture-350w , led well glass fixture-40w , led well glass fixture-45w , led highbay light fixture-150w , led flood light fixture-250w , led flood light fixture-150w , led es lamp-18w , 20w led tubelight fixtures
Tender For supply of corridor light 2 feet 9 watts +_ 10% led version of old 110 dc 2 feet tube light fitting made of min. 1mm thick m.s or g.i fabricated and powder coated sheet. as per new spec.no. clw/es/3/0672 rev.1 and drawing no. clw/es/3/sk- 2/0672 for replacement of old tubefixtures as per old spec.no. clw/es/3/0041in 3 phase electric loco. fixtures do not require any alteration in loco. led shall be of any brand already approved by clw in spec. diffuser shall be of 1.5mm thick fire retardant polycarbonate cover with m.s/g.isheet, powder coated caps on both sides. note: 1) this item is reserved for clw approved sources only as per vendors directory id: 2100755 [ warranty period: 72 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For repairing and overhauling of one no twin lobe air blower assembly and renovation of 2 nos outgoing motor (blower ) feeder of lt pdb with supply, fitting and fixing spares at sludge pump house under swtp, kmda. - supply,installation,testing and commisioning of following items for hoisting system/ blower and gear box as mentioned below as per direction including cost of materials, machinaries , manpower, cutting,machining,aligning,anchoring,welding,finishing,consumables, carriage and all overheads with all leads and lifts complete as per specification (without painting), i) base frame (ms), ii) shaft/pin with key ways made of ss-304, iii) gear& pinion (forged steel), supply and fixing the 3way c.i v grooved pulley with complete mechanism key way suitable to en-24, 60 mm dia/ as per sample of shaft end., a) motor driving, b) blower driving, supply of gear oil as per direction of engineer in charge., supply of grease, supply and delivery of the following bearing (make: skf):, i) 22312e/c3/ as per sample. (for blower), supply and fixing of tough v belts (make: fenner/power boom / v guard/benq/ecodrive) of the following size c 98/ as per sample., supply fitting fixing of ss (aisi304) bolts,nut & washer i) dia 10 mm to 20 mm a) length upto 75 mm, refixing of impeller of blower after dynamic balancing in workshop as per is rule after dismantling the same., dismantling the 25/30 h.p (18.5 kw)//30 h.p squirrel cage motor from its foundation by opening mounting bolts and disconnection of cables from terminal box and open the v belts for repairing purpose (in condition), preliminary checking of the whole motor (lt sq. cage im) and testing of i.r. value, load currents, leakage factor of stator & rotor, terminal lead joints of stator connection ends, insulation of glass fibre terminal bar, double cage rotor end rings and all of motor bars and bar joints, housing of d.e. & nde shield bearing housing etc. before work to detect fault., complete servicing and heat varnishing of 415volt, 3 phase l.t. sq. cage induction motor after cleaning the stator and heating it up periodically and varnishing by dr. beck s graded insulating varnish to obtain stable ir value, cleaning up the rotor, including heating for demoisturisation, lacker coating on the surface of rotor stampings, cleaning and ro priming on the end shield covers, bearing housing and complete the necessary repairing works as per direction of e.i.c.upto 75kw lt sq. cage im ], re fixing the 25/30h.p star/delta squirrel cage motor over its foundation by mean of mounting bolts & nuts, washer complete connection of existing led of cable at the terminal box and wear the v belts with proper alignment in respect to i.d. fan (12000 cu m/hr capacity)/ blower by adjusting the side rail for smooth running., finishing the end of terminal leads by s & f dowells copper sockets properly supplying tapes, petrollium jelly etc. 6 nos.upto 75kw lt sq. cage im., cost of mechanical work viz. shaft truness, checking key way looping of holes grinding and polishing etc. upto 75kw lt sq. cage im., inspection checking/testing and servicing of the existing starter panel, all terminal connection, contactors, relays etc as per desired technical specification including man and minor materials for proper functioning as per direction of eic., supply and fixing of 240/230 volt, 50 hz, t.p., power contactor (make: l & /abb/schneider/ simence/ ge) having contact block of the following range.32-55amp, supply & fixing of 230/240v, led indicating lamp make :ae/kappa/imp) blue/ white color., supply & fixing of 230/240v, led indicating lamp make :ae/kappa/imp) other than blue/ white color., supply and delivery of thermal overload relays (make: l & t/abb/schneider/simence/ ge/minilec) of the following range:a) 0.2-0.33/ 0.3-0,5/ 0.45-0.75, mn2, supply of ammeter selector switch current in each phase with off, 4 pos. 90 angle ofthrow (off-r-y-b) , supply and fixing of analog ammeter ranging
Tender For supply of (i) hscf pump model 6wln16b of capacity 50000 gph/227 m3/hr, head-50 meters, suction/delivery-200/150 mm, casing of pump-2% nici, impeller- cf8m, shaft-ss316, sleeve-ss316 and gland packing. make-wpil or similar, along with (ii) squirrel cage induction motor rating 75 hp, 4 pole. 3-phase, tefc, ie3, ip65, make- marathon/abb/bbl or similar. (iii) fully automatic star delta motor starter panel 75 hp, 415 volt. make- l&k (formerly l & t)/abb or similar. panel-electrocon make. (iv) mandatory spares: impeller(cf8m)-01 no, split gland bush (bronze)-01 set, split gland-01 set, tyre coupling-01 no, neck ring (bronze)-01 set, bearing (de & nde) of pump-01 set, gland packing-01 set motor bearing (de & nde)-01 set, (v) foot valve-01 no, sluice valve ( suc & del)-02 nos, nrv-01 no, pressure guage-01 no, vacuum guage-01 no, tool set. as per cee / grcs spec no. cee/s/185/hscf pump/9/98/revised july 2022. [ warranty period: 30 months after the date of delivery ]
Tender For sh replacement of damaged e.i. work i.e. brunt light points, wire, mcbs switch and tubes fixture - special repair to bus stand at keylong, distt, lahaul spiti (h.p.) (sh : -replacement of damaged e.i. work i.e. burnt light points,wires,m.c.b's switch and tubefixture etc.)
Tender For replacement of defective/burnt tubefixtures, wires and acessories etc at hppwd rest house amb & sub-division amb tehsil amb distt. una (h.p).