Web Analytics Made Easy - StatCounter

Tube Joint Tenders

Get complete information related to latest Tube Joint Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Tube Joint Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Tube Joint Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government And Public Sector

CTN :42401346 Due date: 27 Oct, 202527 Oct, 2025 24.07 Lacs
Tender For insitu replacement re-tubing of heat exchanger tube bundles in main plant of hwpm

CTN :42286907 Due date: 25 Oct, 202525 Oct, 2025 NA
Tender For supply of seal plain oil , dc volt meter , filter assy air intake , spark plug , pipe fuel tube , jointing sheet 4.8 mm thick , fevi quick

CTN :42269970 Due date: 31 Oct, 202531 Oct, 2025 NA
Tender For procurement of after cooler tube bundles for air compressor

CTN :42328618 Due date: 05 Nov, 202505 Nov, 2025 NA
Tender For supply of 114e3050cd tube bundles , 114e3051abd tube bundles , 114e3069ef tube bundles

CTN :42254427 Due date: 01 Nov, 202501 Nov, 2025 NA
Tender For providing of custom bid for services - high-capacity crane for shifting and installation of aph tube bundles

Central Government/Public Sector

CTN :40826419 Due date: 20 Oct, 202520 Oct, 2025 75.06 Lacs
Tender For corrigendum : supply of restoration deicing system of spillway radial gate 1 and 2 trashrack repairing servicing at cps - wall plate heater 16 kw 415 v ac length 7600 mm , skin plate heater 16 kw 415 v ac length 6825 mm , trunion arm heater 3 kw 240 v , cover plate heater 3 kw 240 v , cover plate heater 4 kw 240 v , cover plate heater 2 kw 240 v , thyristor power controller three phase current rating 50 amp , thyristor power controller single phase current rating 50 amp , thyristor power controller single phase currnet rating 40 amp , thyristor power controller single phase current rating 20 amp , temperature controller aux supply 203 v ac input 4 to 20 ma , rtd pt 100 sensor od-6 mm x l50 mm with 1 meter cable with mating connector. , propylene glycol gel industrial grade , hardware items viz. nut bolt washer water tight joint kits for cable heater tubes joints etc , installation testing and re commissioning of deiceing system of spillway radial gates no 1 and 2 and trash rack installed at dam of chutak power station as per the scope of work , annual maintenance contract two visits per year of service engineer for 5 service days for two persons including travelling charges , transportation packing and forwarding

Central Government And Public Sector

CTN :42123496 Due date: 21 Oct, 202521 Oct, 2025 67.01 Lacs
Tender For supply of materials and job work under the work of mc ew c of am special repair to conservation and restoration of entrance gateway of portion of old palace najibabad bijnor 2025 26 - items to be executed, u.s. lime, surkhi, coarse sand, lakhori brick, brick aggregate, sal wood, belgiri, gum, gur, demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of engineer- in-charge., demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 15.2.1 nominal concrete 1:3:6 or richer mix (including equivalent design mix), demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in charge. 15.7.4 in cement mortar, taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :15.13.1 of area 3 sq. metres and below, dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : 15.14.1 of sectional area 40 square centimetres and above, providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40 mm dia m.s. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with m.s. tubes, m.s. tube challis, m.s. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. the scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of engineer-in charge. note:- (1) the elevational area of the scaffolding shall be measured for payment purpose. (2) the payment will be made once only for execution of all items for such works. ( including errection & dismental after work), disposal of rubbish/malba heap,soil etc. from monument to outside of municipal limit by tractor trolly including excavation loading and unloading etc.requirement proper completion of work at monument /site, provision for providing & making lime slacking & mortar pit by means of pit excavation, brick masonry & plastering over it. the size of the over all pit is 8.00m x 3.00m & depth is 0.90m. the pit is divided in to three parts & cement plaster, painting (two or more coats on new work) with oil type wood preservative of approved brand and manufacture, painting(one or more coats) with black japan paint of approved brand and manufacture to give an even shade
 Loading, Please wait...

Connect us via What's Up