Tender For appointment of agency / contractor for housekeeping, carpentry, electrical, gardening, plumbing, caretakers, and allied maintenance works at union bank of india, union bank bhawan,1513/1/1, arera hills, bhopal
Tender For the work of transporting 200 nos. of single phase/three phase approximately 10 box meters, polycarbonate seal and sealing certificate book from electrical storage centre, fatehpur to electrical testing section-fatehpur by vehicle under kampse and dismantling, electrical testing section, fatehpur. after checking the old meters, the work of transporting about 01 tonne of meter spares from electrical testing section, fatehpur to electrical storage centre, fatehpur by vehicle. note- in completion of the above work, if any work is not mentioned in the boq and it is required to be done, then it will be done by the contractor without any other expense.
Tender For supply delivery and replacement of spares for sub-station at mandalkuli water supply scheme , raipur block under bankura mechanical division, phe dte. - "control transformer supply80 va, 240 v / 110 v", "aux contractor supply (4 no 4 nc)make: siemens / abb, coil voltage: 110 v ac", "pcb relay card supply for avr as per existing circuit ", voltage controller potentiometer (1k) supply, "1100 va ups supply output power wattage 660w or equivalent , input-50 hz , wide input voltage range 145-290 v, 2x 7.2 ah (or equivalent) battery , provides 30-90 min power back upmake: apc, input: 230 v ac", "240 sq. mm. x 3 core, 11 kv grade, indoor type, heatshrinkable end termination kit supply ", "240 sq. mm., 11 kv grade, indoor type, heatshrinkable kit jointing charges", "avr throughout inspection and control operation checking and rectification by opening the cover , checking the throughout circuits with aux. contractor replacement charges, pcb relay card with voltage controller potentiometer replacement charges, control transformer replacement charges, old ups replacement and new ups installation charges fixing of heat srinkable kit & other as per direction . ", supply and delivery of following spares for battery charger panel:, supply of 65 ah smf vrla battery with 6 nos cell, polyproplene container make: exide, consisting of 9 nos. 12 v batteries (model-ep 65-12 or equivalent), "charges for old defective battery rack by disconnection all the electrical circuit and fitting fixing of the new battery rack fittings,connection of all batteries checking otesting for a certain period. ", "supply of 2.5 sq. mm x 4 core cu armored cable forbattery charger panel to 3 panel vcb , as per is-7098 (part-i )", gland supply for 2.5 sq mm x 4 core cu armored cable, laying charges of 2.5 sq. mm x 4 core cu armored cable, "charges for glanding & socketing for 2.5 sq mm x 4core cable for battery charger panel: as per direcrion of eic", "supply and delivery of following spares for 400 kva, 11 kv/433 v, transformer-1 & 2:", oti (4 inch. dia) supply make: ptci, "wti (4 inch. dia) supply make: ptci", oti replacement charges, wti replacement charges, "supply of 2.5 sq. mm x 10 core cu armored cable for 3panel vcb to transformer-1 & 2 as per is-7098 (part-i ) ", gland supply for 2.5 sq mm x 10 core cu armored cable, laying charges of 2.5 sq. mm x 10 core cu armored cable , supply of 2.5 sq mm cu pin lugs , supply of 2.5 sq mm cu fork lugs, "charges for glanding & socketing for 2.5 sq mm x 10core cable of 400 kva, 11 kv/433 v, transformer-1 & 2: as per direction of eic", supply and delivery of following spares for single panel vcb:, 240 sq. mm. x 3 core, 11 kv grade, indoor type, heat shrinkable end termination kit supply, 240 sq. mm., 11 kv grade, indoor type, heat shrinkable kit jointing charges, 200-watt space heater supply make: reco, 230 v , "thermostat supplymake: elcon gold, model: mm-106,range: 30? c - 110? c, 15 amp., 230 / 250 v ac", "3 nos. space heater along with 1 no. thermostatconnection wiring charges as per direction of eic", supply and delivery of following spares for 3- panel vcb: , "240 sq. mm. x 3 core, 11 kv grade, indoor type, heatshrinkable end termination kit supply", "240 sq. mm., 11 kv grade, indoor type, heat shrinkablekit jointing charges", 200-watt space heater supply make: reco, 230 v , "thermostat supplymake: elcon gold, model: mm-106,range: 30? c - 110? c, 15 amp., 230 / 250 v ac", 2.5 sq. mm. s/c, 1.1 kv grade control cable supply for space heater and thermostat wiring , "2 nos. space heater along with 1 nos. thermostatconnection wiring charges for each panel as per direction of eic", "3 nos. space heater along with 1 no. thermostatconnection wiring charges as per direction of eic", attending the fault at mandalkuli, bankura district with carrying different testing, servicing kit/machine like insulating resistance checking machine (1 kv, 2.5 kv, 5 kv) 3 phase variac, current injection machine/ kit, voltage
Tender For providing technical manpower through outsource supplier contractor for carry out technical work as 1 jr engineer and 10 wireman at jalgaon municiple corporation building and electrical units areas
Tender For procuremnt of electrical items for hulimangala gp for the year 2025-26 - led bulb 15w, led street light 36 wattage, led street light 100 wattage, led flood light 200w, led flood light 150w, astronomical timer , cfl bulb holders, electric tester, sv chowk 250wattage, led driver 100w, contractor 100amps, pipe clamp 2 inch od, pipe clamp 1 inch od, pipe clamp 1.25 inch od, pipe clamps 1.5 inch od, led street light 50w, led street light 24w, led street light 150w, contractor 50 amps, mcpcb 150w, mcpcb 50w, mcpcb 100w, led driver -1500ma 50w, fuse cutouter 100amps, fuse cutouter 63amps, fuse cutouter 40amps, ip 65 out door led strip, cfl fitting 65w full set, cfl fitting 45w full set, safety glouse, safety shoes 7- 10 inches, cutting palyer, condenser 3way, condenser 2 way, bulb 250w sodium, sodium light full set 250w, mcp - 63 amps 2p, mcp - 40 amps 2p, mcp - 32 amps 2p, mcp - 25 amps 2p, mcp - 16 amps 2p, led bulb 60w, led bulb 50watts, led bulb 40w, led bulb 18watts, pingani cfl holder, gi wire 20 gauge, insulation tape , dp switch 32amps open type, copper cabel 10 sq mm, copper cabel 6 sq mm, copper cabel 4 sq mm, copper cabel 2.5 sq mm, copper cabel 1.5 sq mm, copper cabel 1 sq mm, bed switches 16a, alluminium 6sq cabel, alluminium 4sq cabel, alluminium 20sq cabel, alluminium 16sq cabel, alluminium 10sq cabel, led bulb 30w, led bulb 23w, led bulb 9w
Tender For supply of materials as per the technical specifications given in the work order.shifting of material to work place.inspection of material in presence of indenter.power off the existing system, isolation & removing of existing seal steam control valve hydraulic actuator assembly and shifting to designated area (stores.replacing the new electrical actuator system in the existing location, ensuring of all power, signal cables and power on the system.calibration of electrical actuators and operation shall be carried out locally and from dcs (control room) and feedback shall be ensured.it is the complete responsibility of the firm to execute the job & to bring back the system in to operation without time delay.any additional spares, tools required for carry out the above work shall be contractor/supplier scope.power and signal cable will be supplied by kpcl and cable laying is in contractor scope.the necessary tools, tackles, instruments etc. required for commissioning, testing/ checking the healthiness of the system has to be arranged by the supplier.it is the complete responsibility of the contractor to see that total system shall be commissioned without delay & should function smoothly.any additional sparesitems/tools required to execute the work shall be suppliers scope. additional mechanical civil works shall be included in contractor s scope. single point responsibility of the supplier to execute the job without latching delay.during the warranty/ guaranty period the supplier have to replace any no. of defective spares with good ones (new items) at free of cost, required for smooth functioning of the system. hence you are informed to arrange for new items immediately without any delay.the bidder shall arrange to submit 02 sets of operation and maintenance manual along with approved drawings.the scope is of retrofit/enhancement feature for existing system. hence, it is the responsibility of the contractor to visit the site and study the existing arrangement of the electrical actuator to be retrofitted.integrated site acceptance test for supplied electrical actuator shall be demonstrated to kpcl & mutually acceptance of the same.if any additional materials required for completion of work, the bidderhave to supply and system shall be commissioned with minimum down time.