Get complete information related to latest Tubing Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Tubing Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Tubing Tenders.
Tender For corrigendum : supply of nylon rope ladder complete with 1" dia. aluminum steps as per design. nylon rope of 25 mm dia. with steps of 25 mm dia. aluminum alloy corrugated tubing spaced at 12 c/c duly packed on both sides size 20 feet long with hook for hanging. specification as per attached annexure "a". [ warrantyperiod: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of handpump spare parts at pune zp - supply of handpump spare parts, die set 12mm with handle & bits, hydraulic vice 32 mm., heavy duty clamp 32 mm, heavy duty clamp 65 mm, connecting rod vice, pipe lifter spanner for 32mm n.b.pipe., pipe wrench 300 mm, pipe wrench 450 mm, pipe wrench 600 mm, pipe wrench 900 mm, double ended open jaw spanner 17 * 18 in c.v. steel, hacksaw frame, pump bucket (nitrile) for deepwell hand pump(is: 15500 part 7), sealing ring for deepwell handpumps (is: 15500 part 7), hex nut with bolt m 12 * 40, handle axle along with nut & washer for deepwell hand pump (is: 15500 part 4), single side shielded bearing confiming to is: 15500 part 4 suitable for above handpumps, chain nut with bolt m-12x40 (is: 15500 part 4), chain with coupling for deep well hand pump, head for deepwell hand pump (is: 15500 part 4), third plate suitable for deepwell hand pump (is: 15500 part 4) (im-ll), water tank for deepwell hand pump (is: 15500 part 4) (im-ll), connecting nrod of 12 mm dia. x 3 mtr. length, i.s.i.marked galvanized steel tubes as per i:s 1239 ( part-1) /2004 amdt.1 to 4 scrwed at both ends as per i:s 554/1999 ( reaffirmed 2004) . one end socketed with isi marked socket as per is:1239 ( part -ii)/1992 ( reaffirmed 2003) and other end protected with plastic thread protector medium class , bore size (nominal)diameter 32 mm , length 3 meter, cylinder assembly i.m.ii, cylinder body with brass liner for deepwell hand pump (is: 15500 part 5), reducer cap for deepwell hand pump (is: 15500 part 5) (im-ll), upper valve along with rubber seat for deepwell hand pump (is: 15500 part 6) (im-ll), upper valve assly suitable for deep well hand pump (im-ll) (is: 15500 part 6) (im-ll), lower valve assembly i.m.ii, hacksaw blade (high speed steel), spacer g.m. i.m.ii, rubber seat lower valve (im-ll), rubber seat upper valve (im-ll)
Tender For supply of flexible flame-retardant, high performance,polyolefin heat srinkable tubing, as per drawing: edml176, rev. '0', packing instruction: pi042 ver 3.0 (1) drawing no. icf/j&t/misc-2487 alt. `b? to be followed. (2) it should be ensured that item should not rub during transportation. the item should be packed with adequate strength. transit damage, if any, shall be at the cost of supplier. for underframes: both (1) & (2) to be followed as stated above. for other items except underframes: only (2) need to followed. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of opo 85 multiple- use (reusable, sterile) phaco tubing for compact intuitive phaco-emulsification system [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of tubes and work of insitu retubing as per atc d d - aluminium brass seamless cold drawn tubes , end plate having size of o.d. 267mm, thickness 16.5mm, 190nos. of holes and material s.s. 304 for lube oil cooler of bfp unitunit no. 3 and 4 gtps. , end plate having size of o.d. 205mm, thickness 32mm, 190nos. of holes and material s.s. 304 for lube oil cooler of bfp unitunit no. 3 and 4 gtps. , end plate having size of o.d. 330mm, thickness 25mm, 320nos. of holes and material s.s. 304 for working oil cooler of bfp unitunit no. 3 and 4 gtps. , end plate having size of o.d. 260mm, thickness 40mm, 320nos. of holes and material s.s. 304 for working oil cooler of bfp unitunit no. 3 and 4 gtps. , baffles having size of o.d. 205mm, thickness 04mm both end chamfer and material s.s. 304 for lube oil cooler of bfp unitunit no. 3 and 4 gtps. , 01set equals to 25nos. , baffles having size of o.d. 260mm, thickness 04mm both end chamfer and material s.s. 304 for working oil cooler of bfp unitunit no. 3 and 4 gtps. , 01set equals to 19nos. , work of complete in situ re tubing of old damaged tube cooler of lube oil cooler of 210mw unit no. 3 and 4 as per atc , work of complete in situ re tubing of old damaged tube cooler of working oil cooler of 210mw unit no. 3 and 4 as per atc ) /bid number : gem/2026/b/7336822 * /dated: 14-04-2026 & & / bid document 1 / 12
Tender For supply of abb make ph sensor , abb make ph analyzer , abb make conductivity analyzer , conductivity sensor , annual spares kit , tubing kit exc pump tubes , power supply board panel mount ac
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get