Get complete information related to latest Tungsten Plate Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Tungsten Plate Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Tungsten Plate Tenders.
Tender For supply of laboratory equipment and others materials for existing, accredited district water testing distt. laboratories of division chhindwara - external calibration of laboratory equipment refrigerator/ , visi cooler rtd probe with sensar, glass thermometer, thermometer, wet and dry , thermometer, balance, analytical weight box,ph meter, tds meter, turbidity meter through iso/iec 17025:2017 accredited calibration laboratory with calibration certificate , smart uv-vis spectrophoto meter; 2206 touch screen uv-vis spectrophoto meter, wavelength range 190-1100 nm, accuracy + 1.0 nm, resolution 1.0 nm, bandwidth 1.0 nm. cuvette holder 50 mm path length. with display, with two years amc. with calibration certificate of control of absorbance, resolution power, limit of stray light. light source xenon flash lamp/tungten lamp/ deuterium lamp. to be supplied with 2 pairs of quartz cuvette. size 10 mm. including cost of supply, installation & training to lab staff for making graph of iron, nitrate, flouride, maganese test at nabl accredited lab with certificate. (nabl ceritified) make systronics , color comprator for color analysis , hot plate: rectangular body- heating upto 300'c are fitted with insulated elements. workable on 220/230 volts a.c. surface with cast iron top 300x450x150 mm rating 2 km with digitally , bacteriologycal incubator (memmert type with digital controllar): double walled, outer made of gi/ms powder coated. element of three sides' ss chamber digitally controlled temp. range 5'c above rt to 70 c + 0.5'c fitted with fan having double viewing sindow, supplied with shelves workable on 220/230 volts a.c. size 455x445x455 mm deluxe model with nabl certificate , ion meter versastar banch top modal (ph/ise)with flouride combination, epoxy body electrode with range form 0.01 mg/l ph ross electrode bnc connector, power syplly card opration manual, usb cable, universal ac power adaptor 90-260v ac electrode holding stand, stirrer (1) one pack flouride filling solution 475 ml (2) flouride standard 100 ppm 475 ml solution (3) flouride electrode storing solution 475 ml x 2 no (4) tisab iii solution 475 ml x1 including cost of supply, installation & training to lab staff for making graph of iron, nitrate, flouride, maganese test at nabl accredited lab with certificate. (nabl ceritified lab) , fluoride electrodes (combination fluoride electrode epoxy body with bnc connector) thermo orien -960913 nwp , monoquartz distillation unit-3362 dist. water output cap. (approx) 4.0 lt.hr/ electrical requirements 230-250 volts single phase 3.5x 2kw quartz heater/minimum cooling water requirment 2.5 lit/ min (ea)/ biological activity pyrogen free/ conductivity s/cm <1 x 10-6/ distillate temp 65-75'c , plate colony counter model no. cc-100 220 woult 1 year worenty measurement range 0 to 999 semi autometic precise colony counting metal plastic , laboratry refrigerator rlr-300 cooling type frost free temp. rang 2'c to 8'c glass dour 1, width 584, depth 584,hight 1702,220-240 woult 50 hz singal face , sampling bottel capicity 1 itr , membran filter assembley 5360 all galss filter holder 47mm filtretion assembley made for borosilcate glass with filter base capicity-21tr , spare for all glass filter holder 47mm dai capicity 2000ml for filter holder . tissu paper roll 3 layer
Tender For tyre defect gauge for bg wagons as per drawing plate no.52 rule 3.3.5 & s 4.19.1 of irca part iii enclosed at annexure. condemning thin flange 16 mm and flatness 60 mm. to be supplied with calibration certificate must be submitted at the time of supply of item. specifications and drawing are attached in documents. [ warranty period: 30 months after the date of delivery ]
Tender For manufacturing and supply of complete set of inspection gauges as per rdso drg. no. t-9002(part) for 6400 mm curved switch with 60e1 a1 thick web tongue rails for 1 in 8.5 turnout b.g (1673 mm) for 60e1 rail on psc sleeper to rdso drg. no. rt-6280 for use in depot. along with testing and calibration by any government approved lab or by any nabl accredited labs and confirming to specification, material: 3 mm thick tool steel plate of grade tc-3 (table-1) of is:1570 (part-6) or equivalent or higher hardness. the gauges are to be supplied in in a wooden case. one set consist of (i) gauge no. 1/a & 1/b - end templates at actual toe, (ii) gauge no. 2/a & 2/b- head width checking gauge at point 'h' (22 mm head thickness), (iii) gauge no. 2/1- head width checking gauge at point 'h' (22 mm head thickness), (iv) gauge no.3/a & 3/b - head width checking gauge at point 'h' (55 mm head thickness), (v) gauge no. 3/1- head width checking gauge at point 'h' (55 mm head thickness) [ warranty period: 30 months after the date of delivery ] ]
Tender For manufacturing and supply of complete set of inspection gauges as per rdso drg. no. t-6213(part) for 6400 mm over riding fan shaped curved switch b.g for 60e1 rail on psc sleeper to rdso drg. no. rt-4966 for use in depot along with testing and calibration by any government approved lab or by any nabl accredited labs and confirming to specification, material: 3 mm thick tool steel plate of grade tc-3 (table-1) of is:1570 (part-6) or equivalent of higher hardness. the gauges are to be supplied in in a wooden case. one set consist of (i) gauge no. 1/a- end templates y at point 'r' (ats), (ii) gauge no. 1/b- end templates y at point 'r' (ats), (iii) gauge no. 2- under cutting of tongue rail foot, (iv) gauge no. 3- 13 mm head thickness (at 476.5 mm from ats), (v) gauge no. 6- 12r toe radius at ats, (vi) gauge no. 33- tongue rail head thickness (at 2348 mm from ats). [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of total station, technical speciation: 1) accuracy (iso171-233:2001): 2 second, 2) least count/minimum display: 1 second, 3) data storage: internal memory: 50,000 points & external memory: usb flash memory (max. 32gb). with rechargeable li-ionbatterybdc-71 , quick battery charger cdc77 with power cable, usb/pendrive16gb, carrying bag for instrument, fiber glass telescopic tripod/dual locking system in carrying bag and single prism pole assembly, consisting of: i) pg-2500gp/t prism with holder and target plate in soft carrying case ii) pp-200ev/t graduated telescopic prism pole with bubble in carrying case iii) pp-200ev/t mini prism with mini poles. and calibration certificate, 10 days on site training by company technical representative. make: sokkia or as similar. [ warranty period: 30 months after the date of delivery ]
Tender For tender for the supply of various equipments - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles, karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard, refrigerated centrifuge (bench top), bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples., gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25m (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25m),, "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 l recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:, matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water., ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubings, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 l, 20 l, 50 l, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each of, c8 = 250 4.6 5m c18 = 250 4.6 5m, cyano = 250 4.6 5m. amino = 250 4.6 5m, phenyl = 250 4.6 5m. silica = 250 4.6 5m., all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., ft-ir with atr & liquid cell, " hydraulic press with kbr die and pellet holder, suitable mortar pestle (dia 5-6 cm), suitable portable de humidifier to maintain 30- 60% rh, temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab., reference nist standard polystyrene film (0.3 mm) over the range of 3800 cm-1 to 650 cm-1., abbes refractometer,