Web Analytics Made Easy - StatCounter

Turbine Motor Pump Tenders

Get complete information related to latest Turbine Motor Pump Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Turbine Motor Pump Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Turbine Motor Pump Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45325661 Due date: 02 Jun, 202602 Jun, 2026 1.98 Crore
Tender For replacement of screens gates at saroonagar i and d pump house and removing of accumulated sludge from facultative aerated lagoons(fal) at 172 mld stp nagole

State Government

CTN :45290716 Due date: 30 May, 202630 May, 2026 28.59 Lacs
Tender For deposit 2024 -25 thrikkur gp kundinikadavu pump house supplying and erection of vertical turbine motor pump set for rwph discharge 58lps head-72m -supplying and erection of vertical turbine motor pump set

corporations/Associations/Others

CTN :45314019 Due date: 01 Jun, 202601 Jun, 2026 NA
Tender For regarding inviting quotation for preparation of price list for dry pit non clog sludge pump in stp and etp within the area of pcmc

State Government

CTN :45275642 Due date: 02 Jun, 202602 Jun, 2026 3.07 Lacs
Tender For repairing and overhauling of one no twin lobe air blower assembly and renovation of 2 nos outgoing motor (blower ) feeder of lt pdb with supply, fitting and fixing spares at sludge pump house under swtp, kmda. - supply,installation,testing and commisioning of following items for hoisting system/ blower and gear box as mentioned below as per direction including cost of materials, machinaries , manpower, cutting,machining,aligning,anchoring,welding,finishing,consumables, carriage and all overheads with all leads and lifts complete as per specification (without painting), i) base frame (ms), ii) shaft/pin with key ways made of ss-304, iii) gear& pinion (forged steel), supply and fixing the 3way c.i v grooved pulley with complete mechanism key way suitable to en-24, 60 mm dia/ as per sample of shaft end., a) motor driving, b) blower driving, supply of gear oil as per direction of engineer in charge., supply of grease, supply and delivery of the following bearing (make: skf):, i) 22312e/c3/ as per sample. (for blower), supply and fixing of tough v belts (make: fenner/power boom / v guard/benq/ecodrive) of the following size c 98/ as per sample., supply fitting fixing of ss (aisi304) bolts,nut & washer i) dia 10 mm to 20 mm a) length upto 75 mm, refixing of impeller of blower after dynamic balancing in workshop as per is rule after dismantling the same., dismantling the 25/30 h.p (18.5 kw)//30 h.p squirrel cage motor from its foundation by opening mounting bolts and disconnection of cables from terminal box and open the v belts for repairing purpose (in condition), preliminary checking of the whole motor (lt sq. cage im) and testing of i.r. value, load currents, leakage factor of stator & rotor, terminal lead joints of stator connection ends, insulation of glass fibre terminal bar, double cage rotor end rings and all of motor bars and bar joints, housing of d.e. & nde shield bearing housing etc. before work to detect fault., complete servicing and heat varnishing of 415volt, 3 phase l.t. sq. cage induction motor after cleaning the stator and heating it up periodically and varnishing by dr. beck s graded insulating varnish to obtain stable ir value, cleaning up the rotor, including heating for demoisturisation, lacker coating on the surface of rotor stampings, cleaning and ro priming on the end shield covers, bearing housing and complete the necessary repairing works as per direction of e.i.c.upto 75kw lt sq. cage im ], re fixing the 25/30h.p star/delta squirrel cage motor over its foundation by mean of mounting bolts & nuts, washer complete connection of existing led of cable at the terminal box and wear the v belts with proper alignment in respect to i.d. fan (12000 cu m/hr capacity)/ blower by adjusting the side rail for smooth running., finishing the end of terminal leads by s & f dowells copper sockets properly supplying tapes, petrollium jelly etc. 6 nos.upto 75kw lt sq. cage im., cost of mechanical work viz. shaft truness, checking key way looping of holes grinding and polishing etc. upto 75kw lt sq. cage im., inspection checking/testing and servicing of the existing starter panel, all terminal connection, contactors, relays etc as per desired technical specification including man and minor materials for proper functioning as per direction of eic., supply and fixing of 240/230 volt, 50 hz, t.p., power contactor (make: l & /abb/schneider/ simence/ ge) having contact block of the following range.32-55amp, supply & fixing of 230/240v, led indicating lamp make :ae/kappa/imp) blue/ white color., supply & fixing of 230/240v, led indicating lamp make :ae/kappa/imp) other than blue/ white color., supply and delivery of thermal overload relays (make: l & t/abb/schneider/simence/ ge/minilec) of the following range:a) 0.2-0.33/ 0.3-0,5/ 0.45-0.75, mn2, supply of ammeter selector switch current in each phase with off, 4 pos. 90 angle ofthrow (off-r-y-b) , supply and fixing of analog ammeter ranging

Central Government/Public Sector

CTN :45101853 Due date: 01 Jun, 202601 Jun, 2026 NA
Tender For hiring of diesel pump to drain out rain water/sludge/mud at surrounding areas of various locations in between tihi-gunawad & gunawad-dhar section in connection with dhd -ind new bg line project.

Central Government/Public Sector

CTN :45181178 Due date: 05 Jun, 202605 Jun, 2026 NA
Tender For vadodara division:- hiring of diesel pump and electrical submersible pump to drain out rainwater/ sludge/ mud from surrounding areas of various locations of limited height subway/ level crossing/ road under bridge/ railway colony/ railway station/ railway yard/ shed, etc. under the jurisdiction of divisional engineer (west) vadodara.

corporations/Associations/Others

CTN :44856043 Due date: 28 May, 202628 May, 2026 NA
Tender For corrigendum : supply of centrifugal dosing vertical and metering pumps : : - willo atmosgigan125 315 backpullout , atmos giga32 250 backpullout , atmos gigan65 125 backpullout , atmos igan 65 160 backpullout , willo piso 65 160 backpullout , willo piso 80 250 backpullout , willo piso 65 125 backpullout , willo piso 50 160 backpullout , antico nzp50200tbgv1j backpullout , ro1 cleaning pumpjohnson , sludge pump wilden completassy , ec ph dosing pump xeed completassy , polymer dosing pump xeed completassy , pac dosing pump xeed9 completassy , ro ph dosing pump xeed completassy

CTN :45067095 Due date: 29 May, 202629 May, 2026 NA
Tender For corrigendum : supply of sludge transfer pump with motor in wtp-2

Central Government / Public Sector

CTN :45254531 Due date: 26 May, 202626 May, 2026 NA
Tender For supply of set of consumables for effluent treatment plant (etp), capacity 75 kld. make : clear ion exports. set consists of 1) oil skimmer pump (5 -10 lph) make / brand - visco engineers / vens hydroluft / pp aquatech ss coated ptep (poly tetra flouro ethylene) or any other material of superior quality suitable widthof belt must be use. quantity - 01 no. 2) dosing pump(0-6 lph @ 4 kg/cm2 electronic metering type), make / brand e-dose or grondfo or victor, quantity - 02 nos. 3) activated charcoal/carbon 1000 iv grade, quantity - 250 kgs. 4) sand, graded sand or better, quantity - 850 kgs. 5) poly electrolyte, make / brand - clear ionexports/tescon aua tech /chemtex, quantity - 40ltrs. 6) alum (aluminium sulfate), make / brand - clear ionexports/tescon aua tech /chemtex, quantity - 60 kgs. 7) filter mesh / sludge mesh, quantity - 02 nos. 8) hdpe mbbr media 25x12mm, make / brand - ion exchange / thermax / netsol, quantity - 01 bag[quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

CTN :45022049 Due date: 12 May, 202612 May, 2026 NA
Tender For corrigendum : design, construction, testing, commissioning of all the components of interception and diversion based sewage treatment plant (stp) work including 05 years of operation and maintenance of the entire system.• survey, investigation, design and construction of various diversion drains of inner size 0.50m(w) x 0.50m(h) for a length of 10m, 1.00m(w) x 1.20m(h) for a length of 10m and 1.00m(w) x 1.00m(h) for a length of 210m• survey, investigation, design and construction of coarse, medium screen, grit chambers of various sizes as detailed in scope of work for each wet well.• design and construction of 3 no. wet wells with overhead pump house as per the technical specification• survey, investigation, design, supply, laying, jointing and construction of rising main (di-k9 pipe) of inner dia. 150 mm for a length of 950m and dia. 100 mm for a length of 100m• stp (2 nos) - designing (aesthetically), providing, and constructing and giving satisfactory trials of sewage treatment plant consisting of receiving chamber, screen chamber, grit chamber, measuring flume, distribution chamber with primary and secondary treatment, etc. as per the technical specification of capacity 0.50 mld of facultative aeration lagoon convensional technology including allied units for waste disposal with all civil and mechanical, electrical works involved including administration cum laboratory building of minimum carpet area of 800 sqft. complete with all electrical works.• design and construction of planted drying bed for co-treatment of faecal sludge - 4 nos. of size l- 5.00 x w- 2.00 x height as per design + free board 0.30)• boundary wall around entire stp area, internal and external electrification.• operation and maintenance (o&m) for the proposed works / entire sewerage system (proposed) for a period of 5 years after successful completion of trial run period or handing over whichever is later.
 Loading, Please wait...

Connect us via What's Up