Get complete information related to latest Turbine Motor Pump Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Turbine Motor Pump Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Turbine Motor Pump Tenders.
Tender For replacement of screens gates at saroonagar i and d pump house and removing of accumulated sludge from facultative aerated lagoons(fal) at 172 mld stp nagole
Tender For deposit 2024 -25 thrikkur gp kundinikadavu pump house supplying and erection of vertical turbinemotorpump set for rwph discharge 58lps head-72m -supplying and erection of vertical turbinemotorpump set
Tender For repairing and overhauling of one no twin lobe air blower assembly and renovation of 2 nos outgoing motor (blower ) feeder of lt pdb with supply, fitting and fixing spares at sludge pump house under swtp, kmda. - supply,installation,testing and commisioning of following items for hoisting system/ blower and gear box as mentioned below as per direction including cost of materials, machinaries , manpower, cutting,machining,aligning,anchoring,welding,finishing,consumables, carriage and all overheads with all leads and lifts complete as per specification (without painting), i) base frame (ms), ii) shaft/pin with key ways made of ss-304, iii) gear& pinion (forged steel), supply and fixing the 3way c.i v grooved pulley with complete mechanism key way suitable to en-24, 60 mm dia/ as per sample of shaft end., a) motor driving, b) blower driving, supply of gear oil as per direction of engineer in charge., supply of grease, supply and delivery of the following bearing (make: skf):, i) 22312e/c3/ as per sample. (for blower), supply and fixing of tough v belts (make: fenner/power boom / v guard/benq/ecodrive) of the following size c 98/ as per sample., supply fitting fixing of ss (aisi304) bolts,nut & washer i) dia 10 mm to 20 mm a) length upto 75 mm, refixing of impeller of blower after dynamic balancing in workshop as per is rule after dismantling the same., dismantling the 25/30 h.p (18.5 kw)//30 h.p squirrel cage motor from its foundation by opening mounting bolts and disconnection of cables from terminal box and open the v belts for repairing purpose (in condition), preliminary checking of the whole motor (lt sq. cage im) and testing of i.r. value, load currents, leakage factor of stator & rotor, terminal lead joints of stator connection ends, insulation of glass fibre terminal bar, double cage rotor end rings and all of motor bars and bar joints, housing of d.e. & nde shield bearing housing etc. before work to detect fault., complete servicing and heat varnishing of 415volt, 3 phase l.t. sq. cage induction motor after cleaning the stator and heating it up periodically and varnishing by dr. beck s graded insulating varnish to obtain stable ir value, cleaning up the rotor, including heating for demoisturisation, lacker coating on the surface of rotor stampings, cleaning and ro priming on the end shield covers, bearing housing and complete the necessary repairing works as per direction of e.i.c.upto 75kw lt sq. cage im ], re fixing the 25/30h.p star/delta squirrel cage motor over its foundation by mean of mounting bolts & nuts, washer complete connection of existing led of cable at the terminal box and wear the v belts with proper alignment in respect to i.d. fan (12000 cu m/hr capacity)/ blower by adjusting the side rail for smooth running., finishing the end of terminal leads by s & f dowells copper sockets properly supplying tapes, petrollium jelly etc. 6 nos.upto 75kw lt sq. cage im., cost of mechanical work viz. shaft truness, checking key way looping of holes grinding and polishing etc. upto 75kw lt sq. cage im., inspection checking/testing and servicing of the existing starter panel, all terminal connection, contactors, relays etc as per desired technical specification including man and minor materials for proper functioning as per direction of eic., supply and fixing of 240/230 volt, 50 hz, t.p., power contactor (make: l & /abb/schneider/ simence/ ge) having contact block of the following range.32-55amp, supply & fixing of 230/240v, led indicating lamp make :ae/kappa/imp) blue/ white color., supply & fixing of 230/240v, led indicating lamp make :ae/kappa/imp) other than blue/ white color., supply and delivery of thermal overload relays (make: l & t/abb/schneider/simence/ ge/minilec) of the following range:a) 0.2-0.33/ 0.3-0,5/ 0.45-0.75, mn2, supply of ammeter selector switch current in each phase with off, 4 pos. 90 angle ofthrow (off-r-y-b) , supply and fixing of analog ammeter ranging
Tender For hiring of diesel pump to drain out rain water/sludge/mud at surrounding areas of various locations in between tihi-gunawad & gunawad-dhar section in connection with dhd -ind new bg line project.
Tender For vadodara division:- hiring of diesel pump and electrical submersible pump to drain out rainwater/ sludge/ mud from surrounding areas of various locations of limited height subway/ level crossing/ road under bridge/ railway colony/ railway station/ railway yard/ shed, etc. under the jurisdiction of divisional engineer (west) vadodara.
Tender For corrigendum : design, construction, testing, commissioning of all the components of interception and diversion based sewage treatment plant (stp) work including 05 years of operation and maintenance of the entire system.• survey, investigation, design and construction of various diversion drains of inner size 0.50m(w) x 0.50m(h) for a length of 10m, 1.00m(w) x 1.20m(h) for a length of 10m and 1.00m(w) x 1.00m(h) for a length of 210m• survey, investigation, design and construction of coarse, medium screen, grit chambers of various sizes as detailed in scope of work for each wet well.• design and construction of 3 no. wet wells with overhead pump house as per the technical specification• survey, investigation, design, supply, laying, jointing and construction of rising main (di-k9 pipe) of inner dia. 150 mm for a length of 950m and dia. 100 mm for a length of 100m• stp (2 nos) - designing (aesthetically), providing, and constructing and giving satisfactory trials of sewage treatment plant consisting of receiving chamber, screen chamber, grit chamber, measuring flume, distribution chamber with primary and secondary treatment, etc. as per the technical specification of capacity 0.50 mld of facultative aeration lagoon convensional technology including allied units for waste disposal with all civil and mechanical, electrical works involved including administration cum laboratory building of minimum carpet area of 800 sqft. complete with all electrical works.• design and construction of planted drying bed for co-treatment of faecal sludge - 4 nos. of size l- 5.00 x w- 2.00 x height as per design + free board 0.30)• boundary wall around entire stp area, internal and external electrification.• operation and maintenance (o&m) for the proposed works / entire sewerage system (proposed) for a period of 5 years after successful completion of trial run period or handing over whichever is later.