Get complete information related to latest Turbine Pump Spares Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Turbine Pump Spares Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Turbine Pump Spares Tenders.
Tender For repair maintenance of of iei installation, lift, fire fighting, fire alarm with pa system, compound lighting and water supply pump set and various electrical and mechanical services, at various community halls east zone.
Tender For maintenance of electrical installation and fans repair maintenance of pump sets street compound light diesel generator set at dc office kapashera new delhi sh annual comprehensive and routine maintenance of 160 kva diesel generator set of cummins make
Tender For maintenance of electrical installation and fans, repair maintenance of pump set, street/ compound lights at vasant kunj fire station and sector-6, dwarka fire station under ae (e) sub division -iii, jed-02, new delhi. (sh- supply, installation, testing and commissioning and replacement of old burnt out / defective led fittings with new energy
Tender For (1) repair maintenance of of storm water pump sets and dg sets at bandh road and ssn marg under m-south electrical maintenance division during the financial year 2026-27. (2) moei, pump, lifts of subway, under deck and fob on delhi pwd roads under pwd electrical divi
Tender For auction sale of rolling stock - pl no.98111061, condemned bg-8 wheeler- icf ac coaches 3 nos, without bogie, with all available ferrous, non-ferrous-wooden fittings thereon but excluding the following reclaimable items. 1} coach no. special repair accn 056905 (year built 2005), ds-8 no. 334716 dt 31.03.26, mechanical rc items are common for all three coaches as per sse/c&w/srr letter dt 24.01.2026- 1] complete bogie arrangements including wheel sets 2 nos, 2] buffer plunger and casing 4 nos 3] cbc/screw coupling set [draw bar with hook, draft gear assembly] 2 sets, 4] center pivot 2 nos. 5] bogie mounted brake cylinder 4 nos, 6] distributor valve complete full set 1 set, 7] wearing piece( bronze) and plate 4 nos each, 8] auxiliary reservoir 200 l. 1 no 9] main doors -4 nos 10] cut off angle cock- 4 nos. 11] dirt collector- 2 nos 12] non return valve(fp)- 1 no. electrical rc items as per sse/electrical/srr /letter no.elg/srr/6a dt 23.01.2026- 1] alternator - 2 nos 2] regulator - 2 nos 3]vrla battery -56 nos. 4] tensioning device - 4 no 5] bldc fan 400 mm-8 nos. 6] 150mm fan- 4 nos 7] exhaust fan-04 nos 8]5 w led with fittings (double led)- 16 nos 9] 5 w led with fittings (single) - 5 nos 10] 2w led 8 nos 11] emergency light unit-3 nos 12] d type led fitting - 5 nos 13] md switch-32 nos 14] mobile charger - 16 nos 15] axle pulley -4 nos 16] pumb - 2 nos 17] pre cooling unit - 1 no 18] pre cooling socket -1 no 19] inverter panel- 2 units 20] power panel- 1 unit 21] rmpu- 2 units.. 2} coach no. special repair accn 056904 (year built 2005), ds-8 no. 334717 dt 31.03.26, electrical rc items as per sse/electrical/srr /letter no.elg/srr/6a dt 23.01.2026-1] alternator 25 kw - 2 nos 2] regulator - 2 nos 3] vrla battery -56 nos. 4] tensioning device - 4 no 5] inverter 2 nos 6] bldc fan -8 nos. 7] emergency light unit-2 nos 8] 150mm fan- 4 nos 9] exhaust fan-04 nos 10] 5 w led with fittings (double led)- 18 nos 11] 5 w led with fittings (single) - 1 no 12] 5 w led -5 nos 13] axle pulley -4 nos 14] pump - 2 nos 15] pre cooling unit -1 no 16] pre cooling socket - 2 nos 17] inverter panel -2 units 18]power panel- 1 unit 19] rmpu- 2 units.. 3} coach no. special repair accn 041198 (year built 2004), ds-8 no. 334718 dt 31.03.26, electrical rc items as per sse/electrical/srr /letter no.elg/srr/6a dt 23.01.2026-1] alternator - 2 nos 2] regulator - 2 nos 3]vrla battery -56 nos. 4] tensioning device - 4 no 5] inverter 2 nos 6] bldc fan -8 nos. 7] 150mm fan- 4 nos 8] exhaust fan-04 nos 9]5 w led with fittings (double led)- 18 nos 10] 5 w led with fittings (single) - 6 nos 11] d type 5 w led 2 nos 12] 2 w led-8 nos 13] md switch-32 nos 14] mobile charger - 8 nos 15] axle pulley -4 nos 16] pump - 2 nos 17] pre cooling unit - 1 no 18] pre cooling socket -2 nos 19] inverter panel- 2 units 20] power panel- 1 unit 21] rmpu- 2 units. custodian sse/ c&w/ shoranur.
Tender For auction sale of rolling stock - pl no.98111061, condemned bg-8 wheeler- icf ac coaches 2 nos, without bogie, with all available ferrous, non-ferrous-wooden fittings thereon but excluding the following reclaimable items. 1} coach no. special repair accn 051083 (year built 2005), ds-8 no. 334705 dt 02.04.2026, mechanical rc items as per sse/c&w/srr letter dt 14.01.2026, coach no. special repair accn 051083- 1] complete bogie arrangements including wheel sets 2 nos, 2] buffer plunger and casing 4 nos each 3] cbc/screw coupling complete set [draw bar with hook, draft gear assembly] 2 set, 4] bogie mounted brake cylinder 4 nos, 5] main doors 4 nos, 6] wearing piece( bronze) and plate 4 nos each, 7] distributer valve complete full set 1 set, 8] cut off angle cock- 4 nos. 9] dirt collector- 2 nos electrical rc items as per sse/electrical/srr letter no. elg/srr/6a dt 03.03.2026 and lot inspection report dtd 10.06.26- 1] alternator 25 kw 2 nos, 2] regulator - 2 nos, 3]vrla battery 1100 ah -56 nos, 4] tensioning device 4 nos, 5] inverter 2 nos, 6] pre-cooling transformer amalgamated 1 unit, 7] power panel 1 unit, 8] mobile charger 16 nos, 9] emergency light unit 2 nos, 10] md switch 32 nos, 11] fan 400 mm sweep 1 no, 12] 150mm fan 4 nos, 13] exhaust fan 04 nos, 14] fan 200 mm 7 nos, 15] 5 w led with fittings 24 nos 16] 2w led (night lamp) 8 nos, 17] axle pulley 4 nos, 18] wra 2 nos, 19] change over switch 02 nos, 20] inverter panel 2 units, 21] rmpu 2 units 22] pre-cooling socket 2 nos 2} coach no. special repair wgaccn 056143 (year built 2005), ds-8 no. 334708 dt 21.04.2026, mechanical rc items as per sse/c&w/srr letter dt 15.04.2026, coach no. special repair wgaccn 056143. 1] complete bogie arrangements including wheel sets 2 nos, 2] buffer plunger and casing 4 nos each 3] cbc/screw coupling complete set [draw bar with hook, draft gear assembly] 2 sets, 4] bogie mounted brake cylinder 4 nos, 5] main doors 4 nos, 6] wearing piece( bronze) and plate 4 nos, 7] distributor valve complete full set 1 set, 8] cut off angle cock- 4 nos. 9] dirt collector- 2 nos. electrical rc items as per sse/electrical/srr letter no. elg/srr/6a dt 17.04.2026 and lot inspection report dtd 10/06/2026-1] regulator 25 kw 2 nos, 2]vrla battery 56 nos, 3] inverter 2 nos, 4] bldc fan 8 nos, 5] emergency light unit 2 nos, 6] 150mm fan 4 nos, 7] exhaust fan 04 nos, 8] 5 w led with fittings 21 nos, 9] night lamp 8 nos, 10] d type light fittings 4 nos, 11] mobile charger 16 nos, 12] pump 2 nos, 13] pre-cooling unit 1 no, 14] pre-cooling socket 1 no, 15] power panel 1 unit, 16] inverter panel 2 units, 17] rmpu 2 units 18] alternator 2 nos 19] axle pulley 4 nos 20] md switch 32 nos 21] tension device 4 nos.. custodian sse/ c&w/ shoranur.
Tender For corrigendum : repair and comprehensive maintenance of swimming pool plant and equipments fire fighting system at af stn nal under ge (af) nal - comprehensive annual maintenance of swimming pool comprises of the following equipments complete all as specified and directed.(a) pumping sets of capacity 3.5 hp - 05 nos (01 as standby) (b) pressure filter of filtering capacity 50 cum/hr - 04 nos (01 as standby)(c) dosing pump - 02 nos (one for chlorination and one for soda ash)(d) electrical panel board consisting of starters of suitable rating complete.note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit swimming pool once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of swimming pool.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account. (iii) cleaning all swimming pool building inside, plant room, equipments including surrounding area of the buildings. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of 3.5hp / 3.26 kw capacity and all other connected items., comprehensive annual maintenance of fire fighting system in sekhon hall , new tech flight, sre and new atc of the following equipments complete all as specified and directed.(a) main fire pump with centrifugal motor of existing capacity- 04 nos (b) jockey fire pump with electric motor of existing capacity - 04 nos (c) makeup fire pump- 04 nos(d) dg fire pump with engine - 04 nos note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit fire fighting installation in sekhon hall , new tech flight and new atc once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of installation.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account.(iii) cleaning all fire fighting installation buildings (sekhon hall , new tech flight and new atc) inside, plant room,equipments including surrounding area of the building. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of all existing capacity and all other connected items., s&f in repair pressure pump limit switch of capacity 1psi to 4 psi and 230 volt as per existing make and model fixed on pressure booster line complete all as specified and directed., supply, installation, testing and commissioning in repair of detectors complying with and type certified to en-45 addressable type multi sensor detector with heat and smoke combination with base with self built intelligence as per is:11360 (for annexes) complete all as specified and directed., supply, installation, testing and commissioning in repair of addressable manual call point / pill station resettable type with base complete all as specified and directed, supply, installation, testing and commissioning in repair of fire alarm sounder/siren electronic type horizontal single stage continuous type normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation +5 db 500 mtr complete all as specified and directed, supply and fixing in repair addressable monitor module for activating the sirens complete all as specified and directed, taking out old unserviceable hose box by cutting and welding and s&f hose box made of 18 gauge ms sheet 800mmx 600 mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge ms sheet for keeping 2 nos hose pipe of length 15 mtr each branch pipe nozzle coupling etc and painted fire red out side and brilliant white inside yard complete all as specified and dire
Tender For corrigendum : repair and maintenance of tube wells and boosters including repair of water level gauge, ms panel, sluice valves and allied items of civil / electrical at various buildings i.e. punjab raj bhawan, haryana raj bhawan & residence sector-7, under maintennace booth, sector-7, chandigarh. (ch to: 2216 (np) mtc. and repair ) - repair of ci sluice valve up to 150 mm dia including dismantling, repair / replacement of spindle, nut , rubber packing, nuts and bolts complete., up to 100 mm dia, lifting and lowering of submersible pump set including dismantling of flenged joints, taking out column pipes, re-jointing etc including replacement of defective packing, nuts and bolts etc complete, tube well, booster, supplying and fixing of single phase preventor make minilec or equivalent model of approved make to the satisfaction of eic , supplying and fixing of current transformer ( ct ) for ampere meter of suitable rating complete., supplying and fixing of overload relay of following capacities, 14 to 23 amp, 30 to 42 amp, 45 to 75 amp, providing and fixing of star delta starter timer of make l&t or equivalent model of approved make to the satisfaction of eic, providing and fixing of kit kat 500 amp complete in all respect, supplying and fixing of capacitor of 20 to 50 mfd make l&t, siemens or equivalent model of approved make to the satisfaction of eic , supplying and fixing of analog meter of make l&t ( rishabh ) or equivalent model of approved make to the satisfaction of eic , volt meter, ampere meter, supplying and fixing of 3 pole mccb of following capacity of make l&t, bch, havells or equivalent model of approved make to the satisfaction of eic , 100 amp, supplying & fixing of contactors block of make l&t, bch or equivalent model of approved make to the satisfaction of eic , mnx - 25, mnx - 32, mnx - 50, mnx - 70, supplying and lowering of submersible cable 16mm2 of make havells, finolex, l&t or equivalent model of approved make to the satisfaction of eic , supplying and lowering of submersible cable 25mm2 of make havells, finolex, l&t or equivalent model of approved make to the satisfaction of eic , providing and fixing hydro pneumatic pump of size 0.5 hp of approved make with 24 ltr capacity tank, pressure switch, pressure gauge, nrv accessories and making connections complete of make crompton or equivalent model of approved make to the satisfaction of eic, repair and rewinding of submersible pump set including carriage from installation to workshop and back. the rate include replacement of all defective parts of pump and motor rewinding., 5 hp, 7.5 to 10 hp, 35 hp to 55 hp, repair and rewinding of monoblock submersible pumping set including repacement of defective parts as required and carriage from installation to workshop and back., 0.5 h.p, 1 h.p, 2 h.p, manufacturing, supplying and fixing of ms control panel 16 gauge of size 600x700mm with door including wiring of inside panel, complete in all respect, providing and fixing of self pumping monoblock single phase pump for boosting of make crompton or equivalent model of approved make to the satisfaction of eic, 0.5 h.p, 1 h.p, 2 h.p, providing and fixing of pressure gauge make h-guru or equivalent model of approved make to the satisfaction of eic, providing and fixing of elcb 63 amp make l&t/havells or equivalent model of approved make to the satisfaction of eic, repair of internal control wiring 1.5mm wire with thimbles, nut bolt etc. complete