Tender For the detail of works includes:a. the tenderer shall carryout the following works during annual maintenance contract period along with the servicing of the diesel generator set.1. general checkup & preventive maintenance and to fill up preventive checkup schedule as follows:a) check lube oil level and conditioning of lube oil, top up/refill if required.b) the oil filters shall be replaced whenever oil is changed.c) the air filters shall be cleaned periodically with compressed air, check batteries and top up the distilled water if required.d) check functioning of changing alternator.e) engine safety viz. high water temperature gauge, oil temperature gauge and high speed gauge shall be checked for their functions and repaired/replaced if required.f) coolant level and conditioning of coolant shall be checked and refilled if required.g) check fan and alternator drive belts and tightened if required.h) the governor shall be checked and tuned for proper functioning.i) check for leaks if any and shall be rectified.j) check reports shall be submitted every month/every breakdown calls.2. checking and servicing of engine for smooth running, its unusual sound and color of smoke and exhaust and set it right in case of deviations.3. checking and repairing and leakage of fuel, lubricating oil and coolant.4. cleaning and changing of air filters as per requirement.5. setting of valves tappets whenever required.6. checking and repairing of accessories drive, turbo charger and crankshaft endplay whenever required.7. checking of alignment of engine & alternator as per requirement.8. checking of throttle control and its setting.9. checking of instrument panel including replacement as and when required.10. checking of rotating diodes assembly in brushless alternator including replacement as and when required.11. checking of wiring system and repairing/replacement as and when required.12. repair and maintenance of relays including contractors in control panel.13. checking of battery terminal and de-sulphating.14. diagnosis of faults in engine and alternator and its rectification.15. breakdown calls to be attended on priority within 6 hrs.16. providing spare avrs, self-starter and accessories, free of charge, if the repair/overhaul/replacement is expected to be taken in more than two days.17. checking/repair/adjustment/replacement/servicing shall be carried under annual maintenance contract except cost of component/parts to be replaced due to wear & tear.18. the firm should undertake to arrange genuine spares of the diesel engine, alternator and amf panel as and when required within two working days.19. the tenderer’s service engineer shall visit the site for attending the generator sets not less than twelve times during the contract period (minimum once in a month) and shall inspect the generator set thoroughly. each visit shall take place during 1st week of each month.20. the tenderer’s service engineer shall visit once in two month for checking of electrical side viz. alternator, amf control panel, if any.21. the engine shall be run on no load or at available load, and should be checked for any leakage and abnormal noise. if any such abnormality noticed shall be diagnosed and remedial action shall be taken.22. standard check list:a) replace minor parts (i.e hoses and filters etc) sub-assemblies as and when required.b) service engineers during the visit will report on the performance or any other abnormality and inform parts requirement. he shall also submit the report on work done and recommendations as well as spare parts required.c) attend emergency call on priority (usually same day). however, if the engineer is required or any particular date and time, it would be the responsibility of the customer to intimate the contractor in advance.d) major overhauling/ top overhauling / pt pump & injector calibration /replacement of major parts/ rewinding of alternator or repairs or breakdown of the diesel generator set are to be charge
Tender For corrigendum : providing of custom bid for services - deployment on rental basis of four numbers of mobile lighting towers with minimum 8 meter height from ground level with on board silent diesel generator set of minimum 7 point 5 kva 230 volt single phase rating and hydraulically operated ..
Tender For supply of supply of floor mounted direct radiography system with dual detector under buy-bcak policy floor mounted direct radiography system with dual detector floor mounted direct radiography system with dual detector:- 1.generator the generator should be high frequency capacity of 30 kw or more. kv range should be 40 kv- 125 kv or more. the output at 80 kv should be 400 ma or more. generator frequency should be 200khz or more 2. x-ray tube and collimator the x-ray tube should be of rotating anode with dual focus having the following sizes: (i) large focus: 1.5 mm or less. (ii) small focus: 0.6 mm or less the unit should have anode heat storage capacity of 100 khu or more. distance measuring scale should be provided. should have an multi-leaf collimator having bright light source auto shut provision for the light along with automatic image cropping facility. the light output should be minimum 160lux tube rotation on vertical axis should be - 180 degree locked (clockwise) & + 120 degree (anticlockwise) at least with end stopper. the tube column should be ceiling-free floor mounted and should have longitudinal travel of a minimum 1500mm. touch screen display on tube head to control kvp & mas as well as selection of body parts. 3. vertical detector stand the unit should be provided with vertical stand. the unit should have provision to do all upright x-rays. the vertical detector should travel from at least 1.4 ft to 5.5 ft above floor level. it should be flat vertical motion can be locked in any position. 4. table the table top should be floating with transverse and longitudinal movements 250 mm, 300 mm respectively or better. the table should have a weight bearing capacity of minimum 200 kg or more. the table should have anti scatter grid electromagnetic ) /bid number : gem/2026/b/7398823 * /dated: 28-03-2026 & & / bid document 1 / 8
Tender For bid to ras corrigendum : supply of 5000 v insulation tester , decade resistance box , hv testing kit 250 kva ac , 3 phase portable transformer turns ratio and vector group meter , port. digital dc resistance meter , portable high current digital micro ohm meter , port. prim. and sec. curr. injection test , portable automatic earth tester , univ microproc based relay testing kit , multi mtr digital portable , digital frequency meter , digital sound level meter , digital tachometer non contact type , digital tachometer contact type , cable fault location set , testing kit for calibrating the digital energy meter , sf6 gas leak detector , hydrogen gas leak detector , vacuum measurement meter , portable light intensity lux meter , portable circuit breaker motion analyser , thermal imaging camera , portable high voltage live line detector , tong tester , portable phase seq continuity indicators , dc leakage analyser , standard tool kit , relay tool kit , hv discharge rod and portable earthing equipment , hot stick upto 400 kv , multimeter analog,portable , portable digital ammeter ac , portable digital ammeter dc , portable digital voltmeter , portable dc earth fault leakage reactor , auto-transformer variac single phase , auto-transformer variac three phase , rheostat 50 ohm , 5a , rheostat 250 ohm , 1a , rheostat 1000 ohm , 1a , potential trf test set kit , crimping tool hand operated , crimping tool power operated , lcr meter bridge , battery impedance test equipment , ac clamp adapter , bench top digital multimeter , natural frequency tester , elcid- elec mag core impern detn kit , function generator , multifunction instrument calibrator , power quality analyser , meter test bench , surge comparison tester , sweep frequency analyser //bid details 2 / 50