Web Analytics Made Easy - StatCounter

Turbogenerator Tenders

Get complete information related to latest Turbogenerator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Turbogenerator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Turbogenerator Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Private Sector

CTN :41799387 Due date: 30 Sep, 202530 Sep, 2025 NA
Tender For sale of gas turbine and generator with auxiliaries , steam turbine and generator with auxiliaries and heat recovery steam generator (hrsg)

Central Government/Public Sector

CTN :41828667 Due date: 03 Oct, 202503 Oct, 2025 NA
Tender For supply of stg3 governor control system as per tender specifications,mandatory spares for stg3 governer control system as per tender specifications,commissioning and training charges for steam turbine generator 3 governor control system

CTN :41455951 Due date: 13 Sep, 202513 Sep, 2025 NA
Tender For corrigendum : supply installation and commissioning of lab. equipment for mechanical engg dept - steam turbine power plant setupfeatures steam power plant and its components start-up, operation and shut down of a steam power plant closed steam-water circuit with feed water treatment among others, determining:o boiler efficiencyo mechanical/thermal efficiency of the turbineo condenser efficiencyo specific fuel consumption of the plantspecificationsteam generator steam output: 200kg/h at 11bar fuel consumption: 12l/h heat-up time: 8min pressure: 13barsuper heater power: 7kwsingle-stage axial turbine with curtis wheel and hydraulic speed regulator power: max. 1,5kw at 3000min-1water-cooled condenser cooling capacity: 98kw transfer surface: 2,5m2measuring ranges temperature: 9x 0 400 c, 2x 0 100 c flow rate: 0 167l/min (cooling water) pressure: 3x 0 16bar, 1x 1bar torque: 0 20nm speed: 0 4000min-1400v, 50hz, 3 phases400v, 60hz, 3 phases, 230v, 60hz, 3 phasesdimensions and weight l x w x h: 3500x 2500 x 2250 mmweight (approx.): 2250 kg, rotary air compressor test benchfeatures: to study all components/accessories used in rotary air compressor. to study & determine isentropic work, actual work volumetric efficiency, isentropic efficiency & free air delivery at different delivery pressure. to plot volumetric efficiency/isentropic efficiency against delivery pressure & comment on the nature of the plot.observations can be taken by air compressed in storage& free condition. instrumentation: sensors with digital displays software for data acquisition via usbspecifications: vane compressor rotary compressor, driven by 3 hp motor. calibrated orifice meter with water manometer to measure air intake. energy meter to measure input of the meter. pressure gauge to measure discharge pressure. control valve at delivery side. stop clock.dimensions and weight: l x w x h: 1500x 1500 x 1250 mmweight (approx.): 320kg, marcet boiler test apparatusfeatures: recording the vapour pressure curve of water presentation of the relationship between pressure and temperature in a closed system temperature and pressure measurementspecification:bourdon tube pressure gauge: -1 24bartemperature limiter: 200 csafety valve: 20barheater: 2kwboiler, stainless steel: 2lmeasuring ranges temperature: 0 200 c pressure: 0 20bar230v, 50hz, 1 phase230v, 60hz, 1 phase120v, 60hz, 1 phasedimensions and weight: l x w x h: 800x 600 x 600 mmweight (approx.): 45 kg, slip & creep apparatusmaterial: stainless steelmotor type: dcpower : 1 hpspeed: 1500 rpm, universal governor apparatustype: digitaldriven type: pulley material: steeldisplay: digitalspindle material: stainless steelpower source: electricmotor type: dcvoltage: 220 v, motorized gyroscope apparatusmaterial: steeldisc material: stainless steel disc diameter: 300 mm thickness:12 mm weights: 2 kg, 1 kg, 1/2 kg, driven type: motorised, static & dynamic balancing apparatusmaterial: stainless steeldisplay: analogdrive motor: fhp motor, radical angle dekkor unitradical angle dekkor unit comes with objective lens aperture of 28mm. measuring range of 10 mtr. read out of 1 mtr. telescope length of 250mm. brass body of 240x300mm, closed grains casting hardened, stabilities and scrapped. light source of 6v 15w.ardened1) focal length of objective 220mm.2) clear aperture of objective: 40mm3) magnification: 11x.4) measuring range: 60-0-60 minute in x-y axis.5) least division on of arc raticle : 1 minute6) least division with micrometer drum: 2 second of arc, cylinder bore gauge50 to 150mm range (metrology calibrated with dial indicator 0.001 increments), thickness gauge (ultrasonic type)resolution: 0.01 mm (0.001 inch) for thickness upto 99.99 mmmemory capacity: 5000 readings, auto colimatorauto colimator g.g. make autocollimator a.a. 10 is a versatile model capable of meeting various measuring requirements involving small angles & displacements in linear & flatness testing.a. collimator unit.objective lens

Central Government And Public Sector

CTN :41446495 Due date: 11 Sep, 202511 Sep, 2025 NA
Tender For corrigendum : tender for supply of supply of amc of turbogenrator e e - capacitance and tan delta test on stator winding of 235mwe turbogenerator refer detail scope of work in attached technical specification. , supply of partial discharge test pd on stator of 235mwe turbogenerator refer detail scope of work in attached technical specification. , supply of stator core imperfection detection elcid test for 235mwe turbogenerator refer detail scope of work in attached technical specification. , supply of wedge tightness test for stator of 235mwe turbogenerator refer detail scope of work in attached technical specification. , supply of natural frequency test for stator of 235mwe turbogenerator refer detail scope of work in attached technical specification. , supply of polarization - depolarization current analysis on stator winding of 235mwe turbogenerator refer detail scope of work in attached technical specification. , supply of digital repetitive surge oscillograph rso test on rotor winding of 235mwe turbogenerator refer detail scope of work in attached technical specification.
 Loading, Please wait...

Connect us via What's Up