Get complete information related to latest Tv Cabinet Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Tv Cabinet Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Tv Cabinet Scrap Tenders.
Tender For corrigendum : supply of hrc cylindrical fuse 2amps 500v, 120ka, size 10 x 38mm use in secondary circuit o f 100va control transformer of switch board cabinet of lhb type ac coaches and power ca rs, suitable for fitment in existing holder. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : e-tender (2nd call) for procurement of laboratory instruments, equipment, appliances for the college of veterinary sciences and ah, rk nagar under the nec funded project for the year 2025-2026 - biosafety cabinetclassii, a 2 with accessories and power back up (bacteriology)-- the biological safety cabinet should be of class ii, type a2 designed in compliance with international standards the biological safety cabinet quoted instrument model must have international standards test likensf, tuv nord, en 12469 certification. certificate copy must be provided along with the technical bid. working area should be around 4foot. it should have exterior dimension w x h x d of 1300x 1568 x 800 and interior dimension wxhxdof 1200x 780x 630 it should have 1 piece grade 304 stainless steel or thermos scientific smart coat interior itshouldhavefeatureforpersonalprotection,sample protection, cross contamination protection and environmental protection. it must utilize brushless dc motor technology which uses significantly less energy with less heat emission provision compared to traditional ac motor technology to ensure lower levels of energy consumption. it should have 10 sloped front for exceptional comfort and ergonomics thesystemshouldbedesignedwithdualmotor. the motor must automatically adjust or control fan speed in real time to maintain constant airflow during filter loading or temporary obstruction. air flow direction: vertical laminar flow & air intake across front opening and 70% recirculation. filter: high performance particle air filter h14(hepa en1822), filtering efficiency 99.995% mpps or better. energy saving mode when cabinet not in use with maintaining sterility. continuous airflow helps to maintaina sterile environment, evenwhen the cabinet is not in use. thesystemshouldhaveindependentsensorstodetect pressure changes across the exhaust and down flow plenum/ air velocity and should indicate alarm signal when a 20-30% change in inflow/ exhaust or down flow occurs. control panel and performance monitor displays inflow/ down flow velocities, hours of use etc. to verify proper cabinet operation. frontglasswindowshouldbeeasilyloweredfor thorough smart cleaning of inner surfaces and designed to protect users by maintaining inflow, even when the window is lowered. the uv light must be quoted which should be programmable from 30 min to 24 hrs. in minimum 30 minutes increment to shut off automatically. the settings must allow the user to program the timer. the cabinet noise level must be less than 63 db(a) as measured in a sound proof room to promote more comfortable and safer working habitsof the user a per nsf/ ansi 49. the controller must be located on a slanted frontpanel so it is easy to see from a seated working position in front of the cabinet. control panel should be a large digital color touch screen display with health monitoring system, valuable safety and performance data with constant read-out of downflow/ inflow velocities and hours of operation in real-time, number of hours of use on the hepa filters. the front window sash must be angled 10 sloped front for operator comfort. two pieces of removable and autoclavable stainless steel arm rest should be provided for operator s comfort without disturbing the air flow. the system must have audio visual alarms to indicate when inflow is restricted and as well as whether front window is in correct position or not. theworkareashouldbeilluminatedwithswitchable fluorescent lamp of lighting power >120 fc or higher. suitable height floor stand without casters should be provided. in built access ports, 2 nos. (1 on each side) shouldbe available. it has single piece stainless steel work tray for easy cleaning and decontamination. warranty:minimum3year. electrical supply available: 230v a.c, single phase, 50 hz. bidder should provide printed brochure of the quoted model and details specification should be available in the manufacture website. customized model would not
Tender For supply of contactor for 60 kva transformer current rating 95 amp. rated voltage: 690 v ac, mai n pole: 4, aux. contact: 1no+1nc, control voltage: 168-300v ac means 230 v ac +/- 30% with surge suppressor, make: abb/ sneider only and as per rdso letter no. el/7.1.108/mssbc dated-17.09.2021 for common bill of material of switch board cabinet, [ warranty period: 30 months after the date of delivery ]
Tender For supply of hog a & b control auxiliary contactor (s2k8 & s2k9) with 24v dc coil, aux. 3no+ 4nc suita ble for switch board cabinet for hog compliant lslrd coaches as per rdso specification no. rdso/pe/spe c/tl/0195-2019 (rev.-0).material is schneider part no. ca3kn31bd+la1kn04 or siemens part no. 3rh2122 -1bb40+3rh2911-1ha22 or abb part no. nfzb44ert-21 or l&t part no. mo0 dc or c&s electric part no. t ca3dn22bd+ta1dn22/ tca3dn22fd+ta1dn22. material shall procure from above said oem or his author ized dealers or firm who submit authorization of said oem only [ warranty period: 30 months after the da te of delivery ]
Tender For supply of hrc cylindrical fuse link 4a (without holder), 1.2 kv size 8x50mm for voltage control as per sr.no.13 and item code f01 to f06 and place of installation s1 f90 to s1 f96 of bill of material of r dso spec no. rdso/pe/spec/ac/0184-2015(rev-1) used for voltage control fuse of lhb type ac coach es confirming to rdso spec no. rdso/pe/spec/ac/0184-2015(rev.1) suitable for lhb type ac coache s switch board cabinet (s1f-90, s1f-91, s1f-93, s1f-94, sif-95, sif-96) accepted makes:1) siba 2) bu ssman 3) ferraz (or) 4) wohner [ warranty period: 30 months after the date of delivery ]
Tender For supply of high voltage hrc fuse base (holder) suitable for hrc fuse 2 amps, 1.2 kv, cylindrical type, size:8x50 mm used in primary of 200va control transformer or metering lhb-ac pwr panel 2a fuse insula tion supporting with earth of switch board cabinet of lhb ac coaches confirming tordso spec. no. rdso/p e/spec/ac/0184-2015 (rev-0) or latest material make shall be siba or siemens or abb or eaton bussman or eti or l&t or similar [ warranty period: 30 months after the date of delivery ]
Tender For supply of contactor for 60 kva transformer, rated current : 95 a, rated voltage : 690 v ac, main pole : 4, aux. contact: 1no + 1nc, control voltage : 230 v ac (168 v ac - 300 v ac means 230v ac +/- 30%) with surge suppressor, suitable for switch board cabinet of rdso spec. no. rdso/pe/spec/ac/01 84 (rev.1). acceptable make abb model no.-af116b-40, schneider model no.-lc1d1150046m5+la4da 2u. [ warranty period: 30 months after the date of delivery ]
Tender For supply of contactor for 60 kva transformer, rated current : 95 a, rated voltage : 690 v ac, main pole : 4, aux. contact: 1no + 1nc, control voltage : 230 v ac (168 v ac - 300 v ac means 230v ac +/- 30%) with surge suppressor as sr no 36 of list of bom given in annexure of rdso letter no. 7.1.108/ m ssbc dt. 17.09.2021, suitable for switch board cabinet of rdso spec. no. rdso/pe/ spec/ac/0184 (rev .1). acceptable make:- abb, schneider, c&s as per s.n.36 of the bom in the annexure of rdso letter n o. el/7.1.108/mssbc dated 17.09.2021 (f/14) and rdso letter no. el/7.1.5/sbc/garib rath dt-10/11/23 (f/19 sn 10) or latest. [ warranty period: 30 months after the date of delivery ]