Get complete information related to latest Tv Tower Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Tv Tower Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Tv Tower Repair Tenders.
Tender For request for proposal (rfp) for empanelment of architects/consultants and contractors in various financial categories-civil construction/repairing work including plumbing, furnishing work including repairing of furniture, electrical work including operation/maintenance/repairing of electrical installations,air-conditioning work including operation/ maintenance services of standalone (window /split / cassette/ tower) air-conditioning units, catering ,housekeeping ,pest control
Tender For electrical/trd for the work of uluberia(ulb): increasing of csl of dn main, middle line & up main line at ulb station and provision of signalling facility and connectivity of tower wagon shed with emu stabling line alongwith signaling facility for emu stabling line at hwh end.
Tender For electrical/trd for the work of uluberia(ulb): increasing of csl of dn main, middle line & up main line at ulb station and provision of signalling facility and connectivity of tower wagon shed with emu stabling line alongwith signaling facility for emu stabling line at hwh end.
Tender For electrical work for temporary three phase, 10 kw electric connection in favour of m/s reliance jio infocomm limited near no.3 level crossing puri gate, kamakhya mandir for tele-communication tower (1-wb-kgpr-enb-008).
Tender For supply of testing of earth pit , testing of relay , thermography of equipment , preparation of earth pit layout , testing of insulation mat , load testing of battery bank , transformer oil testing , testing of transformer tan delta , testing of transformer partial discharge , routine testing of transformer , servicing and testing of vcb , wti winding temperature indicator calibration , oti oil temperature indicator calibration , buchholz relay testing , testing of third harmonic la , testing of vcb bottle , vlf testing of cable 100 percent , polarization index testing motor , insulation resistance testing , electrical safety audit , calibration of voltmeter , calibration of ammeter , cablibration of energy meter , cablibration of power factor meter , acb servicing and testing , pair of ht electrical gloves, 25 kv, is 13774 2021 , pair of lt electrical gloves, 1.1 kv, is 4770 1991 , insulation mat 2.5 mm, lt, is 15652 , insulation mat 3 mm, ht, is 15652 , oltc oil testing as per is 1866 , dga of transformer oil , transformer oil filtration , thermal omicron b2hv relay test , testing of mccb , testing of rccb , pi of power cables , current transformer testing , digital megger meter , led 300 watts for high mast tower , digital ampere meter , communication cable tester , digital clamp meter * /bid number : gem/2026/b/7664367 + /dated: 17-06-2026 ' ' / bid document 1 / 51
Tender For engagement of project management consultant (pmc) for providing mep like high and low side electrical, hvac, fire protection system, lifts, fire alarm and public address system and plumbing works ,facade with lighting and interiors in integrated andhra pradesh state secretariat and hod offices (gad tower,tower 1 and 2,tower 3 and 4) in amaravati government complex, andhra pradesh)
Tender For supply of miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1) (q2) , moulded case circuit breakers (mccb) conforming to is/iec 60947 (part 2) (q2) , led luminaire for road and street lights conforming to is 10322 (part 5/section 3) (v3) (under bis scheme - ii) (q2) , self ballasted led lamps (led bulb) (v3) conforming to is 16102 (part 2) (under bis scheme - ii) (q2) , plasticized pvc tapes with non-thermosetting adhesive for electrical purpose (v2) isi marked to is 7809 (part 3/ sec1) (q2) , non modular piano type domestic electrical switches isi marked to is 3854 (q2) , electrical plugs (v2) isi marked to is 1293 (q2) , led batten light (led tube light) (v2) (q2) , led luminaire for floodlight conforming to is 10322 (part 5/section 5) (v3) (under bis scheme - ii) (q2) , xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , water storage tank , plywood bwr , led tube , copper cable , wire mesh , hydraulic door closer , cable , plywood bwr , whb , led batten , power contactor , db mcb tpn , wire mesh , particle board , flat back urinals , ewc , cpvc sdr , curtain rod alu , cable pvc , looking mirror , isolator 4 pole100 amps , fan regulator , tower bolt alu , led mirror light , helical door spring , db mcb spn , bow handle , ply wood bwr , sheet aluminium , sliding door bolt , wire mesh pvc , butt hinges , m seal , led lamp , cpvc tank adaptor , screw wood , door stopper aluminum , door handle , cpvc female brass threaded , capacitor , metal clad ac box , modular socket 20 ampr , curtain rod brackets aluminum , switch socket combination , sliding door bolt alu 300 mm , tower bolt alu 100 mm , hasp and stapple alu , screw wood 50 x 8 g , butt hinges alu 75 mm , bracket ci for flat back urinal , butt hinges ms 50 mm , modular socket 10 amps , tower bolt alu 75 mm , teak wood beading , tower bolt alu 200 mm , mortice lock 6 levers left , bow handle alu 100 mm , fevicol , butt hinges alu 125 mm , cpvc brass elbow , screw wood 35 x 6 g , butt hinges ms 100 mm , modular switch 10 amps , cpvc brass reducer elbow , cpvc brass tee , call bell ding dong , cpvc adaptor , nails wire round 50 mm , nails wire round 75 mm , modular switch 20 amps , rubber washer , syphon washer pvc , modular plate 8 module , plug top 3 pin 15 amps , hasp and staple , modular plate 3 module , modular plate 12 module , angle holder , modular plate 6 module , cpvc adaptor 25mm female , screw wood , metal clad ac plug , lugs aluminium , screw wood 25 x 8 g , cpvc adaptor 25mm male , cpvc adaptor male 20 mm , cpvc female adaptor 20 mm , screw wood 40 x 8 g , switch bell push , lugs aluminium 240 sqmm , lugs aluminium 300 sqmm , plug dummy gi 20 mm , insulation tape20 mm , lugs aluminium 150 sqmm , lugs aluminium 120 sqmm , lugs aluminium 70 sqmm , lugs aluminium 95 sqmm , flexible conduict pipe 25 mm , lugs aluminium 50 sqmm , lugs aluminium 25 sqmm , lugs aluminium 35 sqmm , lugs aluminium 16 sqmm , xlpe cable water storage tank 1000 ltr cap, plywood bwr 8 ft x 4 ft x 12 mm per sheet 2.88 sqmtr , led tube for t8 fittings 20 watts aluminium body, water storage tank 500 ltr cap, plywood bwr 8 ft x 4 ft x 18 or 19 mm , led tube for t5 fittings 18 watt aluminium body, 3 core copper round cable 2.5 sqmm 100 mtrs coil, wire mesh aluminium 0.9 or 1 mtr x 15 mtr 0.45mm, ss plate rack trade patern size width 900 mmx length 750 x 250 mm , hydraulic door closer left and //bid details 2 / 122
Tender For corrigendum : reconstruction of damaged retaining wall and providing toe wall at tower no 137 of 132kv d c transmission line from larji to kangoo under electrical system division hpsebl bilaspur
Tender For corrigendum : reconstruction of damaged retaining wall and concreting on upside bench at tower no138 of 132kv d c transmission line from larji to kangoo under electrical system division hpsebl, bilaspur