Get complete information related to latest Tying Wire Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Tying Wire Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Tying Wire Tenders.
Tender For tender for worksupply, laying, testing and commissioning of 11kv /22 kv ug cable (xlpe cable will be supplied by dgvcl) with cable termination and straight through joints kits (to be supplied by contractor) for laying underground cable in any scheme at yogi chowk sub division & any sub division under surat rural division.
Tender For on risk & cost piped water supply scheme for village- radhakrishnanagar (colony,purvtola,schoolpara) ,jamuniya(uraonpara,khaspara,) ,bata(baigapani, sarnatoli,banjutola, masjidpara, saraidih,bichtola, kataidih, khaspara) block- sankargarh district – balrampur(c.g.)construction, testing and commissioning of r.c.c. elevated service reservoir of 00 kl capacities – 00 no. & staging 12 mtr& staging 12 mtr {steel structure 12 m height & 10 kl (5000l x 2no.) – 7 no. and steel structure 09 m height & 10 kl (5000l x 2no.)- 01 no.} pe tank & elevated service reservoirs of rcc staging and hdpe slim tank of capacity 5000 ltr of 00 no. 9 mtr staging (with switch room of size 1.8mx1.8mx3m) and 10000 ltr of 00 no. 12 mtr staging.including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber.providing, laying, jointing, interconnection, testing and commissioning of rising main upvc class 10 kg/sqcm 90 mm dia 00 m & hdpe 75mm dia 00 m & 63 mm dia 990 m., distribution upvc class 6kg/sqcm 90mm dia. 00 m., 110 mm dia. 00 m., 140 mm dia. 00 m. 160 mm dia. 00 m.& distribution hdpe class 6kg/sqcm 63 mm dia. 25257 m., 75 mm dia. 10374m.with suitable joints gi pipe, valve, specials and all fittings including all allied civil works, supplying & installation of energy taging n five star bee rating isi marked required capacity single phase / three phase, 50 hz, 220v,, deep well submersible pump stainless steel body, suitable for 4”/6” tube well with contral panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,ss/nylonwireropeandconnection cable including verification of tubewell yield& electric connection from cspdcl, construction of brick masonry switch room, construction of boundary wall around the over head tank, installation of electro chlorinator , construction of chlorinator room of providing functional household tap connection (f.h.t.c. 622 ) in individual households and government instiution etc. complete with trial run of 03 months after that o&m of 06 months under piped water villege radhakrishnanagar(colony,purvtola,schoolpara), jamuniya(uraonpara, khaspara,), bata(baigapani,sarnatoli,banjutola, masjidpara, saraidih,bichtola, kataidih, khaspara) block- balrampur,rajpur,kusmi district – balrampur(c.g.)
Tender For corrigendum : maintenance- repairs- replacement of electrical items for various projects executed under srinagar smart city limited for a period of 2 years. - supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage, delivery and erection of following sizes of distribution transformer at site., i) 630 kva distribution transformer, ii) 400 kva distribution transformer, iii) 250 kva distribution transformer, iv) 100 kva distribution transformer, v) 63 kva distribution transformer, fixing of fabricated gi angle/channel/flat/pole collars., fixing of galvanised nuts and bolts., supply, installation, testing, commissioning, insurance, unloading, carriage and delivery at site, laying, stringing and binding of conductor including joints with pg clamps of required following size of acsr conductor (0.1 /0.05/ 0.03), i) 100 sqmm acsr (dog), ii) 50 sqmm acsr (rabbit), iii) 30 sqmm acsr (weasel), supply, installation, testing, commissioning of ab (ht) cable of following sizes:, iii) 50 mm ab (ht) cable (3x50+1x70 mm ) xlpe(11 kv, 3c +earth), iv) 70 mm ab (ht) cable (3x70+1x95 mm ) xlpe(11 kv, 3c +earth), v) 95 mm ab (ht) cable (3x95+1x95 mm ) xlpe(11 kv, 3c +earth), vi) 120 mm ab (ht) cable (3x120+1x95 mm ) xlpe(11 kv, 3c +earth), mid span straight through jointing kit for 11 kv abc of following sizes:, i) 11 kv abc 50-95mm straight through jointing kit (3 core), ii) 11 kv abc 120-185mm straight through jointing kit (3 core), iii) 11 kv abc 240-300mm straight through jointing kit (3 core), heat shrinkable outdoor cable termination kit for ht/lt abc of following sizes:, i) 11 kv abc 70-95 mm outdoor cable termination kit, ii) 11 kv abc 120 mm outdoor cable termination kit, iii) 11 kv abc 150-185 mm outdoor cable termination kit, iv) 11 kv abc 240-300 mm outdoor cable termination kit, supply, installation, testing, commissioning of ab (lt) cable of following sizes:, ii) 50 mm ab (lt) cable ( 3x50 + 1 x 16 + 1 x 35) mm xlpe (1.1kv, 3+1 c, al), iii) 70 mm ab (lt) cable (3 x 70 + 1 x 16 + 1 x 50) mm xlpe (1.1kv, 3+1 c, al), iv) 120 mm ab (lt) cable (3 x 120 + 1 x 25 + 1 x 95) mm xlpe (1.1kv, 3+1 c, al), straight through cable jointing kit for lt abc of following sizes:, ii) 50 mm ab (lt)straight through cable jointing kit, iii) 70 mm ab (lt)straight through cable jointing kit, iii) 120 mm ab (lt)straight through cable jointing kit, dismantling, i) dismantling, stacking of 9/8 mtr st poles and transportation back to divisional store as per the instruction of electrical incharge., ii) dismantling of 0.03/0.05/0.1 acsr conductor and transportation to divisional stores (servicible), servo voltage stabilizer, i) supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 63 kva, 3-phase oil cooled servo (complete job), ii) supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 50 kva, 3-phase oil cooled servo (complete job), rmu, supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 4 way type,two isolators and two circuit breakers 11 kv, ring main unit ,sf6 insulated, out-door type, extensible type,breaking capacity 25 ka for one second with sf6 circuit breaker / vcb self powered with o/c + e/f relay comprising of a) 11kv 630 amp motorised isolator including earthing switches with making capacity 52ka, having mechanical on/off, earth indications with fault current indicator.b) 11kv ,400 amp motorised spring operated, circuit breakers with earthing switches, connecting the rmu to supply transformer. c). copper bus bar of 630 amp rating.d). 1 no numerical aux. powered relay having non directional o/c and e/f protection (for each ciruit breaker).d). the circuit breaker enclosures shall be outfitted with a communicable-type numer
Tender For corrigendum : repair/maint of 11 kv ht cable joints and other related works and repair/maint of over head lines and connected works at technical and domestic area at af stn gwalior
Tender For - arc of electrical material. - electrical work :, providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 10% humidity 10% to 90% rh working temp -5c to 45c . driver current 750ma. the luminaire shall be bis certified and trade mark certified. life expectancy equal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities for led fixtures. (lm79/lm80) certificate/ report with liable warranty of product/accessories from oem shall be submitted. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . led street light fixture with minimum lumen output 5600 lm, supplying and drawing of xlpe insulated lt aerial bunched aluminium conductor cable confirming to is 14255/1995 and is 398 (pt-4)/ 1994 and as per discom specs. on existing cross arms through i hook with all necessary t&p required including binding and twisting etc. complete in all respect as required. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . 1 x 25 sq. mm. + 1x25 sq. mm. (insulated), supply and fixing of 11 kv pin insulator confirming to is:731:1971 with latest ammendment on existing bracket including all accessories like ms forged hot dipped gi pin confirming to is 2486(part-i)/1993 & is:2486 (part-ii)/1989 with latest amendment, and as per latest discom specs. etc. as required. all as per pre approved by engineer in-charge.for additional technical parameters of product / work refer annexure a attached with this bsr, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . c
Tender For supply of dc ammeter , ac ammeter , dc voltmeter , ac voltmeter , wattmeter , power factor meter , rheostat , rheostat double tube , wire striper , screw driver , plier , nut driver , pop spaner , line tester five hundred volts , cable cutter , pvc batten , pvc conduit , pvc casing and caping batten , hydraulic crimping tool , hand crimping tool , mcb single pole , dpmcb , module box for fitting of switches sockets etc , switches , fan regulator , socket , angular holders , main switch dpmcb , changeover switch , elcb , rccb , two way switch for module fitting , ordinary electric bell , relay for bell circuits , wooden board , acsr wire dog conductor for making joints practice , g i pipe earthing with all accessories , g i plate earthing with all accessories , electric iron , water heater , heat convector , desert cooler , room heater , mixer , blender , drilling machine , pvc bends , pvc junction boxes , clamp on meter , soldering iron station , lamp , variac , dc regulated power supply , kcl kit , kvl kit , galvanometer , conversion of galvanometer into ammeter and voltmeter kit , wheatstone bridge , capacitor , lead acid battery , lithium ion battery , battery management system and controller for electric scooty , induction coil air core iron core , rl rc and rlc kit for active reactive and apparent power , load bank , current transformer , potential transformer , earth tester , megger insulation tester , energy meter , inductive load bank , capacitive load bank , patch cords , cro probes
Tender For various types of furniture materials - table 3 x 6 1. size:3 feet (width) 6 feet (length) 2.5 feet (height) approximate.2. material:frame and legs made of seasoned teak wood (moisture content 10%).tabletop made of 18 25 mm thick isi-marked commercial board / plywood, of approved quality.all wooden parts shall be termite-proof and kiln-seasoned.3. top finish:top covered with 1 mm thick laminate (matte / glossy) of approved shade and brand.all edges sealed with 2 mm pvc edge banding or polished teak beading.surface to be smooth, scratch-resistant, and heat-resistant.4. drawers & box unit:three lockable drawers on one side, mounted on telescopic channels for smooth sliding.one storage box / cupboard with hinged door and locking arrangement on the other side.all drawers and box interiors finished with melamine or laminate.5. legs & frame:made from solid teak wood sections (minimum 2 2 ), joined with proper mortise and tenon joints.cross supports / bracing provided for additional rigidity and strength.6. hardware:branded locks, handles, channels, and hinges (e.g., godrej / hettich / ebco or equivalent).high-quality adhesive and screws used for assembly.7. polish / color:melamine / pu polish in natural teak, walnut, or as approved by the department.uniform finish without marks or uneven coating.8. quality requirements:table must be sturdy, termite-resistant, moisture-protected, and wobble-free.workmanship should be neat and conform to standard office furniture design.minimum load-bearing capacity: 75 kg distributed load on tabletop.9. warranty:minimum one-year warranty against manufacturing or structural defects., table 4 x 6 1. size:4 feet (width) 6 feet (length) 2.5 feet (height) approximately.2. material:frame & legs: made of first-class seasoned teak wood, moisture content not exceeding 10%.top: 25 mm thick isi-marked commercial board / plywood of approved brand and grade.drawer & box components: 18 mm commercial board with teak wood beading on exposed edges.all materials must be termite-proof, moisture-resistant, and well-seasoned.3. top finish:tabletop finished with 1 mm thick premium laminate (matte or glossy) of approved shade and brand (e.g., greenlam, century, merino).edges: 2 mm pvc edge banding or solid teak beading, finely polished.surface should be smooth, scratch-resistant, and heat-resistant.4. drawers and storage box:three lockable drawers on one side with telescopic channels for smooth movement.one storage box / cupboard with hinged door and individual lock on the same side.all drawers to have soft-closing mechanism and branded locks/handles (godrej / hettich / ebco or equivalent).inner surface of drawers and box to be laminated / melamine-coated for a clean finish.5. frame and support:legs of solid teak wood (2" 2" or heavier section) with cross bracing for strength.all joints properly mortised and tenoned, fixed with wood adhesive and screws for rigidity.table should be wobble-free and stable.6. polish / color:pu or melamine polish of natural teak / walnut / oak shade (as approved).finish to be uniform, smooth, and glossy.7. hardware & accessories:all fittings (locks, hinges, channels, handles) to be branded and rust-proof.cable hole with grommet on top for wiring management.8. quality & strength:structure must be durable, termite-resistant, and long-lasting.tabletop load-bearing capacity minimum 100 kg (uniform load).corners rounded for safety and aesthetics.9. warranty:minimum one-year comprehensive warranty against any manufacturing or structural defect., computer table1. size:approx. 1200 mm (l) 600 mm (w) 750 mm (h)(4 feet 2 feet 2.5 feet)2. material:top: 18 25 mm thick pre-laminated particle board / mdf board / plywood, isi-marked, of approved brand (e.g., century, greenply, action tesa).frame / legs: mild steel (ms) tubular frame (25 mm 25 mm 1.2 mm thick) with powder coating, or solid wood frame as specified.keyboard & cpu units: same material as tabletop (laminated board).3. c
Tender For supply of laying and construction of 4 inch nb steel pipeline with hot tapping at angul dhenkanal ga d d -pipeline laying installation by open trench method , pipeline laying installation by hdd without casing , long radius bends 300 class 90 degree , purging and inertisation of 4 inch pipeline including supply of nitrogen , hot tapping works , tcp work , supply laying termination glanding and ferruling tcp cables , supply laying termination glanding and ferruling of tcp cables , supply laying termination glanding and ferruling tcp cable , supply laying termination and glanding and ferruling tcp cable , tlp test stations , pipeline laying installation of above ground pipeline , pipeline laying installation of above ground pipelines , pipeline laying and installation of above ground pipeline , supply of assorted pipe fittings and flanges , supply of assorted pipe fittings and flange , supply of assorted pipe fittings flanges , flanges , supply and installation of 90 degree elbow r 1 point 5d rating 300 class , supply and installations of 90 degree elbow r 1 point 5d rating 300 class , sockolet a105 sw , unequal tee a234 gr wpb charpy b 16 point9 and 1 point 5d bw , reducer a234 gr wpb charpy bw , supply of plug valves , ball valves underground , erection of valves as per p and id above ground , erection of the valves as per p and id above ground , erection of the valves as per the p and id above ground , radiography test of weld joints , radiography test of the weld joints , field instruments , installation calibration testing and commissioning of pressure gauges , civil work construction and handing over of brick valve pit as per tender drawing
Tender For corrigendum : supply of replacement of lt incoming panels at various locations and cable termination d d - room panel-2 as per technical spec and sow. , supply of gas operator room panel-3 as per technical spec and sow. , install, replacement, testing and commissioning of gas operator room panel-3 as per technical spec and sow. , supply of 3. 5c x 400 sq. mm aluminum cable. ss4 to gas operator room as per technical spec and sow. , laying, fixing, testing and commissioning of 3. 5c x 400 sq. mm aluminum cable. ss4 to gas operator room as per technical spec and sow. , supply of 3. 5cx 70 sq. mm aluminum cable. ss4 to fire service dept. as per technical spec and sow. , laying, fixing, testing and commissioning of 3. 5cx 70 sq. mm aluminum cable. ss4 to fire service dept. as per technical spec and sow. , supply of 3. 5c x 25 sq. mm cable. pump house 1 to pump house operator room as per technical spec and sow. , laying, fixing, testing and commissioning of 3. 5c x 25 sq. mm cable. pump house 1 to pump house operator room as per technical spec and sow. , supply part for end termination. as per technical spec and sow. , service part for end termination. as per technical spec and sow. , supply part for new earthings with 75mm ci cast iron pipe and gi flat as per is standards 3043 and as per technical spec and sow , service part for new earthings with 75mm ci cast iron pipe and gi flat as per is standards 3043 and as per technical spec and sow , supply of gi flat 25 x 6mm necessary joints with nut and bolts from earth pit to panel boards. as per technical spec and sow. , laying of gi flat 25 x 6mm necessary joints with nut and bolts from earth pit to panel boards. as per technical spec and sow. , civil works - breaking of existing concrete and excavate the cable trench up to 60cm depth provide sand 45mm thick lay the3. 5 core 400sq. mm lt 1. 1kv ss4-gas operator room , civil works - breaking of existing black top road and excavate the cable trench up to 60 cm depth provide sand 45mm thick lay the 3. 5 core 70sq. mm lt. ss4 to fire service dept. , a. foundations for lt panels at all locations, b. creation of power room for lt panels in gas operator room with al partition