Web Analytics Made Easy - StatCounter

Ultra Performance Liquid Chromatography Tenders

Get complete information related to latest Ultra Performance Liquid Chromatography Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ultra Performance Liquid Chromatography Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ultra Performance Liquid Chromatography Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45263804 Due date: 01 Jul, 202601 Jul, 2026 4.63 Crore
Tender For corrigendum : tender for the supply of various equipments - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles, karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard, refrigerated centrifuge (bench top), bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples., gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25m (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25m),, "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 l recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:, matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water., ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubings, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 l, 20 l, 50 l, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each of, c8 = 250 4.6 5m c18 = 250 4.6 5m, cyano = 250 4.6 5m. amino = 250 4.6 5m, phenyl = 250 4.6 5m. silica = 250 4.6 5m., all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., ft-ir with atr & liquid cell, " hydraulic press with kbr die and pellet holder, suitable mortar pestle (dia 5-6 cm), suitable portable de humidifier to maintain 30- 60% rh, temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab., reference nist standard polystyrene film (0.3 mm) over the range of 3800 cm-1 to 650 cm-1., abbes r

State Government

CTN :44943510 Due date: 19 Jun, 202619 Jun, 2026 22.54 Crore
Tender For corrigendum : tender for the supply of various equipments required for upgradation of district food laborartory, karnal - bottle dispenser, deep freezer -20°, 400 l, deep freezer -40°c, capacity 400 l, abbe, refractometer, automated solid, phase extraction, system, electro magnetic, sieve shaker, solvent filtration, unit, automatic, glassware, washers and, dryers, rotary evaporator, with chiller, homogenizer, ultra sonic bath, digital butyro, refractometer, analytical balance, (0.0001 gram, (accuracy), hot air oven, polarimeter, ph meter, muffle furnace, vacuum oven, deep freezer -80°c, micro balance, refrigerator 700 l, (double door &, frost free), water purification, system, inductively coupled, plasma – mass, spectrometer (icpms), microwave digestor, gas chromatography, with tandem mass, spectrometry (gcmsms), lc-ms/ms, ics aquion - specs, ultra performance, liquid, chromatography, (uplc) with photo, diode array, (pda),fluorescence, (fld) and, refractive index, detector(rid)

CTN :44522613 Due date: 14 Apr, 202614 Apr, 2026 NA
Tender For corrigendum : procurement of spares for rawl 02 mk ii a system - procurement of b&d spares of rawl 02 mk iii system - 2kw power amp assy, rf driver unit, power combiner (l band), power supply unit - sspa, coupler dual dir n(f-f) 1-2ghz 15 f.w 5008, passive solid state limiter, connector rf 50 ad waveg-u-ide to co-axial, vswr aasy, radar signal distribution pcb, interface pcb, stc card, wgm, signal processor, digital video gen card, radar video interface card, tracker card, centroider card, downconverter pcb assy, upconverter pcb assy, synthesisor pcb-1, synthesisor pcb-2, l0-1 pcb assy, l0-2 pcb assy, status card - lo, status card - up, status card - dc, lna box assemly, detector dual channel 10-400mhz 10db, power supply unit-rx, motor starter manual 6.3a to 10a, fuse mains 30a 600v, fuse time-lag cube 600v 10a, pdu accs voltage relay, relay ph-montrg dgtl 3ph 3x90 to 400vac, contactor 4p 440vac 22a, contactor 3p 440vac 22a, filter emi 3ph m5 480vac 20a, filter emi 3ph m5 480v ac 30a, filter emi 1ph ms 300vac 10a, pou control card, power supply ac-dc 1ph 230 vin mlt-0/p, wg driyer spares, chiller spares, circuit breaker mcb 4p 10ka 230v 16a, miniature circuit breaker 2a,10ka, miniature,circuit breaker 8a, 10ka, miniature circuit breaker 4a, dpu mother board, rx- mother board, rx -child mother board, cold plate assy(sspa), rfd cold palte assy, cold plate assy(combiner), hose assy 1(ss 316), hose assy 2(ss 316), hose assy 3(ss 316), hose assy 4(ss 316), hose assy 5(ss 316), hose assy 6(ss 316), hose assy 7(ss 316), hose assy 8(ss 316), hose assy 9(ss 316), hose assy 10(ss 316), flow sensor 1.5-30 l/min, socket hex-27x50, plug hex-22x44.5, panel indication lamp, 230v, 8mm, red, panel indication lamp, 230v, 8mm, yel, panel indication lamp, 230v, 8mm, blue, bma straight jack smp female right-angle, bma straight jack smp female right-angle, bma straight jack smp female right-angle, bma straight jack smp female right-angle, cable assy bma straight jack sma rt280mm, cable assy bma straight jack sma rt180mm, bma straight jack sma straight plug flex, cable assembly ,2 sma right-angle plug s, 60 contracts double row cable assembly, 60 contracts double row cable assembly, conn rj 45 panel mount, sma adapter (female to female), con cirs thd pl ss11 mn13/3a crp tpl, conn cir st pl 25ss 19pos crp w/o cont, conn rf75 pin coax size 12 fir cablerg17, cable assy set-rf dr-iv--r 0/p, combiner cas set, 1/2" superflex cable (p-3110501), 1/2" superflex cable (p-3110501), 1/2" superflex cable (p-3110501), 1/2" superflex cable (p-3110501), 2 n-18 right-angle plug shf8 350mm, ddc - wg to coax adapter cable, conn cir pl st 5525 17p crp w/bma coax, conn cir pl st 5521 20p crp w/bma coax, bpa assy, control card (slave) asy, pre driver assy, driver 1 25w assembly, driver 2 500w assembly, control card(master) assy, main bias card, amplifier pwr 30mhz to 3 ghz 1w, power combiner 4- way, detector assy, track ball, sealed, 50mm, 88 key backlet panel (usb), waveguide assy 90deg e-bend 1.2-1.4 ghz, waveguide assy 90deg h-bend 1.2-1.4 ghz, flexible wave guide, circulatr hp 1.2-1.4ghz 10kw, rugged 24 port switch

State Government

CTN :43927260 Due date: 08 Apr, 202608 Apr, 2026 4.63 Crore
Tender For corrigendum : tender for the supply of various equipments required for upgradation of district food laborartory, karnal - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles", karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard", refrigerated centrifuge (bench top),, bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples.", gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25µm (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25µm),", "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 µl recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water.", ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubing’s, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 µl, 20 µl, 50 µl, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each ofc8 = 250 × 4.6 × 5μm c18 = 250 × 4.6 × 5μmcyano = 250 × 4.6 ×5μm. amino = 250 × 4.6 × 5μmphenyl = 250 × 4.6 ×5μm. silica = 250 × 4.6 × 5μm.all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate.", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate.", ft-ir with atr & liquid cell, "• hydraulic press with kbr die and pellet holder• suitable mortar pestle (dia 5-6 cm)• suitable portable de humidifier to maintain 30- 60% rh• temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab.• ref
 Loading, Please wait...

Connect us via What's Up