Tender For supply of powder free latex surgical gloves microptic size 7point 0 polymer coated surgicals gloves with dermashield extra coatind facilites dry and amp , powder free latex surgical gloves microptic size 7point 5 polymer coated surgicals gloves with dermashield extra coatind facilites dry and amp , powder free non latex sterile surgical ultra thin neoprene gloves size 7point 0 100 chemical accelerator das free synthetic glove , powder free non latex sterile surgical ultra thin neoprene gloves size 7point 5 100 chemcal accelerator das free synthetic glove , silk braided size 1 oblique 0 70 das 76 cms taper cut 1 oblique 2 circle needle 25mm , silk size 2 oblique 0 70 das 80cm 1 oblique 2 circle taper cutting needle 25 das 30mm eu ce oblique us fda oblique , onco surg , scratch pad for electrocautery , skin marking pen thick marking with a flexible scale sterile peel open pouch , closed wound suction drain unit with 02 x perforated pvc drain with 01 trocar 01 spring loaded bellows and connecting tubing size 12 fr , closed wound suction drain unit with 02 x perforated pvc drain with 01 trocar 01 spring loaded bellows and connecting tubing size 16 fr epoint g romovac oblique polymed , closed wound suction drain unit with 02 x perforated pvc drain with 01 trocar 01 spring loaded bellows and connecting tubing size 14 fr epoint g romovac oblique polymed , titanium ligaclips 100 mm cartridges box of 36 cartridges , titanium ligaclips 200 mm cartridges box of 36 cartridges , titanium ligaclips 300 mm cartridges box of 18 cartridge , titanium ligaclips 400 mm cartridges box of 18 cartridges , polymer ligating clip small green box of 14 cartridges oblique box , hemolock size extra large grey 6 pcs oblique cartridge 14 cartridge oblique box , hemolock size large purple 6pcs oblique cartridge 14 cartridges oblique box , reusable clip applicator for open surgery compatible with ligaclip das 100 , reusable clip applicator for open surgery compatible with ligaclip das 200 , reusable clip applicator for open surgery compatible with ligaclip das 300 , reusable clip applicator for open surgery compatible with ligaclip das 400 , solution anti fog for endoscopy box of 20 , curved circular intraluminal stapler 21 das 25mm orvil orvil for 25mm circular staplers , freka trelumina c4 16 oblique 9 150cm enteral tube , underwater seal drainage for use with thoracic drainage catheter with trocar , abdominal drain kit sterile having drainage catheter and collection bag 2000 ml graduated bag soft drainage catheter 28 fr , skin stapler with 35 stainless staples , skin stapler remover , aami level das 3 reinforced performance sterile surgical gown consists of five layer sfsms fabric with two hand towel das , multi ligaclip applicator for open surgery containing 25 das 30 large clips , multi ligaclip applicator for open surgery containing 25 das 30 small clips , patient scrub kit das disinfectant for pre das surgery patient bathingpoint should include chg 4 100ml solution with medical grade polyurethane , synthetic absorbable polydioxanone suture monofilament voilet size das 3 oblique 0 1 oblique 2 circle round body double needle 26mm 70cm box of 12 , synthetic absorbable polydioxanone suture monofilament bolet size das 4 oblique 0 1 oblique 2 circle round body rb das 1 double needle 17mm 90cm box of 36
Tender For expression of interest of (eoi) for planning, design and detailed assessment for establishment of modular dental operation theatre / dental surgical unit at sadar hospital, latehar.
Tender For bid to ras supply of abscess drainage set pigtail type with ip needle guide wire j tip ptfe coated dilators drainage bag connector scalpel 10fr , disposable mouth piece filter with niose clip for spirometry compatible with ganshorn body box , enzymatic cleaner with amylase lipase protease and cellulose , lignocaine spray 10 percentage bott of 50 ml , recombinant human tissue type plasminogen powder for inj 20 mg , salmeterol 50 mcg fluticasone 250 mcg multi dose dry powder inhaler of 60 , salmeterol 50 mcg fluticasone propionate 500 mcg accuhaler dose inhaler 60 doses , acebrophyllin 100mg nac n acetycstine 600mg tab , budesonide 160 mcg formoterol fumarate 4 point 5 mcg dry powder multi unit dose inhaler 60 dose , nintedanib 150mg tab cap , oseltamivir 75 mg cap , budesonide 500 formoterol 20 mcg respules , dpi umeclidinium62 point 5mcg vilanterol 25mcg fluticasone furoate 100mcg 30 doses , pigtail drainage catheter set including no 11 surgical blade initial puncture needle gidewire set of dilators pigtail catheter connecting tubes 12f , bipap mask full face medium , oscillaring postive respiratory pressure device , rotacap glycopyrronium 25 mcg formeterol fumarate 12 mcg budesonide 400 mcg , vilanterol 25 mcg fluticasone furoate 100 mcg glycopyrronium 50 mcg inhalation powder pack of 30 , pirfendione 800 mg tab , tobramycin respules 300 mg 2 ml , metronidazole inj for iv use containing 500mg per bott of 100 ml , adrenaline tartrate 1 1000 1 ml inj , dexamethasone sodium phosphate 4 point 4 mg equivalent to dexamethasone phosphate 4 mg ml 2 ml inj ) /bid number: gem/2026/b/7136862 * /dated: 11-02-2026 & & / bid document1 / 24
Tender For corrigendum : short term e-bid for rate contract cum supply and empanelment of surgical items - "syphilisantibody (rapid) detection kits1. the assay should be based on rapid chromatographic immunoassay for qualitative detection of antibodies (lgg, lga & lgm) to tp in serum, plasma & whole blood.2. the assay should utilize recombinant treponemal antigens i.e. tp15, tpl7, tp47 against syphilis.3. the assay should be in card format.4. adequate documents detailing the principle components, bio- safety methodologies, validity criteria, interpretation of results, performance characteristics storage conditions, limitation of assays manufacturing & expiry dates should be provides with each kit.5. the kit should have approval of the statutory authority in its country of origin.6. in case of imported kits it should be registered and licensed under the provisions of drugs & cosmetics act and rules and/or medical devices rules 2017 in india.7. in case of indigenous manufacturers should be licensed under the provisions of drugs & cosmetics act and rules and or medical devices rules 2017 issued by the competent authority defined under drugs and cosmetics act, 1940.8. the kit should have minimum shelf- life of 5/6th or 12 months (whichever is more) at the port of discharge of consignees.9. read result time should not be more than 20 minutes.10. assay should have sensitivity 100% & specificity 99 %or more with documentary evidence.11. the storage & transport temperature of the kit should be 2-30 c.12. the pack size should not be more than 50 tests wherein each test is individually", bed side leucodepletion filters for blood transfusion (for 2 unit of red cell) [ne32b] 1. filters should be able to leucodepletered cells form leukocytecontamination separately for 1 unitof red cells and for 2 units of redcells each.2. filters should be having thecapacity of log 4 reduction(99.99%)3. filters should not carry anycharges it should be neutrallycharged.4. filters material should bepolyester woven / non- woven.5. leukocytes should beconsistently averaging less than0.5x105 residual leucocytes forone unit of red cell and 0.2*106for two units of red cell. rbcrecovery should be averaging morethan 90%.6. filters should have hard / softhousing for optical monitoring.7. filtration loss should not bemore than 35 ml for one unit redcell.8. should have integrated 40 m,micro aggregate filter.9. should be us fda/ europeance certified., hepatitis b surface antigen (elisa) testing kits iv generation/high sensitiveshould have microplate elisa coated with either polyclonal or monoclonal antibodies to hbsag and either polyclonal or monoclonal antibodies in conjugate. the assay should be able to detect all the 11 subtypes (ad & ay subtype) including mutant strains. the assay should be able to detect surface antigen to hepatitis b virus., hbsag (rapid test)
Tender For supply of 69072 - spine drapes drape - us fda approved, ce certified spine drape should contain 6 sheets with a separate sterile sheet for surgical site and fluid collection unit for endoscopic surgery [ warranty period: 30 months after the date of delivery ]