Tender For corrigendum : supply of accessories/ consumables/ spares for medical equipment - temperature cable for blt monitor part no 15-031-0066, accessories stand,wall mount for blt monitor part no 15-031-0099, nibp hose cable for blt monitor part no 15-031-0008, nibp cuff adult for blt monitor part no 15-100-0118, spo2 sensor clip type (one piece)for blt monitor part no 15-100-0358, spo2 sensor clip type for blt monitor part no 15-100-0320, spo2 analog extension cable for blt monitor part no 15-100-0357, five-5 lead ecg cable set clip type for blr monitor part no 15-031-0022, five-5 lead ecg cable set snap type for blt monitor part no 15-031-0002, three-3 lead ecg cable set for blt monitor part no 15-031-001, rs232 communication board for schiller tmt machine (stmt), kit screw stickers epure- sav-01-0024 for ot light, model epure, ball values for drain for-ultrasonicinstrument cleaner, epure keybord- sav-01-0025 for ot light, model - epure, analog timer for ultrasonicinstrument cleaner., cover glass 1 complete set for famed -mobile lamp., reusable bipolar with fixed plug , 3m-for electro surgical unit (cautary unit) make- eschmann, model- td830, mattress head section (50mm) t20-431-0001), vpx exhaust hose part no-216018 for eschmann suction unit -1no, compressor for sarns tcm ii, battery li-ion - schiller ecg machine, kit sp2 x battery 12 v,80 w hrl 1280 w-part no 001-20-0058, three axis pcb for ot table make- eschmann , model t20a & t20a+ installed at major ot, vpx valve hose part no-216013 for eschmann suction unit, vpx vacuum gauge part no-743077 for eschmann suction unit, vpx vacuum control valve part no-216059 for eschmann suction unit, vpx manifold hose part no-216016 for eschmann suction unit, vpx handle bar grip part no-216076 for eschmann suction unit, vpx gauge hose part no-216014 for eschmann suction unit, thermal print head for schiller ecg machine, hv board for defibrillator dg 400 for schiller defibrillator, recorder paper for schiller defibrillator, thermal printer head with rollar for schiller defibrillator, battery for schiller defibrillator, recorder pcb for schiller defibrillator, adult contact plate for schiller defibrillator, left and right keypad for schiller defibrillator, left and right keypad pcb for schiller defibrillator, paddle pcb for schiller defibrillator, encoder knob for schiller defibrillator, smps module for schiller defibrillator, relay interface board for schiller defibrillator, lcd for schiller defibrillator, hv board 200j for schiller defibrillator, wooden platform for schiller tmt machine (stmt), walking belt for schiller tmt machine (stmt), nibp tube 3m-reusable-2601195 for monitor, model- vista-120, make- drager, smps for schiller tmt machine (stmt), relay board for schiller tmt machine (stmt), opto coupler - speed for schiller tmt machine (stmt), opto coupler - elevation for schiller tmt machine (stmt), main transformer for schiller tmt machine (stmt), main motor for schiller tmt machine (stmt), iu pcb for schiller tmt machine (stmt), interface cables edc to iu, tmt to iu for schiller tmt machine (stmt), eprom for schiller tmt machine (stmt), elevation motor for schiller tmt machine (stmt), edc pcb for schiller tmt machine (stmt), ac drive unit for schiller tmt machine (stmt), ten lead patient cable for schiller tmt machine (stmt), expiratory valve for evita, reusable-8410580, safely disk for maquet (datascope) iabp machine- data scope, recorder board for maquet (datascope) iabp machine- data scope, purge assembly for maquet (datascope) iabp machine- data scope ., pressure transducer cable for maquet (datascope) iabp machine- data scope ., power supply module for maquet (datascope) iabp machine- data scope ., motor controller pcb for maquet (datascope) iabp machine- data scope ., modem board for maquet (datascope) iabp machine- data scope ., main cpu pcb for maquet (datascope) iabp machine- data scope ., front end pcb for maquet (datascope) iabp machine- data scope., fill assembly for m
Tender For corrigendum : fabrication work d d - places , replacing wornout runner base and installing a new runner base of cane carrier and baggage elevator and r b c , replacing wornout runner with new one of cane carrier and baggage elevator and r b c , removing wornout angle iron and t iron of the cane carrier and reinstalling it by straightening the crooked part , removing the wornout part of the suit from different places and fitting it with new one , chevron grooving of new rollers of the mill , chevron grooving of old rollers of the mill , remove the wornout partition plates of the juice box above and below the juice heater by 10 or 12 mm ms plate and install it , installing ribs at the top and bottom partitions of the juice heater , repairing save all of qurdbody , removing old wornout gutters installed at various places and installing it with new gutters , remove the old wornout save all from pan and quard and install it with new one , reinstalling the new umbrella fitted inside the pan by making a new one and removing the old one , replacement ribbon arm of the mascute receiving crystallizer , making new separator of a centrifugal machine , removing the wornout truff of the hopper and installing it with new one , making and installing new separators for continuous centrifugal machines , removing the tubes of quad juice heater and dynamic juice heater and expanding them by installing new tubes and giving their hydraulic testing satisfactory of size 42 mm , removing the tubes of pan installing new tubes and expanding them and giving hydraulic tesing with satisfactory trial of size 96 mm , removing the wornout flue gas ducting of both the boilers and installing it with newone making from new or old plates , removing the wornout front and roof plate at boiler number 1 and 2 and installing with a new plate , removing the damaged boiler damper and installing a new one , making bagasse suit and installing. , replacement of juice over flow box of clarifier , making and installing bed of motor and pumps at various places as per requirement , replacement 6 inch dia cooling pipe of sulfur furnace , removing the monitor casing of a machine from old machine and installing it and giving its a trial , making amd replacing manholes at various places , making and replacing the enternals of cather of the pan. , making and replacing the new hood of cane cutter , removing the old bottom plate of the lowest compartment of the clarifier and placing a new plate on it after placing an angle trap as per the instructions and giving a satisfactory water trial , reinstalling the stirrer of the clarifier and giving a satisfactory trial , removing the shaft of a pug mill and replacing the old bushes on both sides and fitting new ones , removing and refitting the shaft of a brown sugar magma mixer and installing with new bush , reinstalling the trufff of connecting rod of the hopper , making and installing new catcher strainer , removing the old rail line of the trolley of the unloader and fitting the new rail line satisfactorily and doing water level , reinstalling the old rail line of the unloader s bridge and fitting it and checking water level etc , removal of old and weak channels of 3 inches to 10 inches diameter installed at various places and installation of new ones as per requirement , cutting and straightening old plates installed at various places as per requirement , removal of old and wornout scrubber installed on sulfur furnace and making and replacing with 8 or 10 mm plate and making all the connections , removing the trufff plate including support corroded shell and top cover plate of the top chamber of the clarifier and fitting the new plate and giving it s a water proof trial , re-installation alignment and //bid details 2 / 47 trial of hopper driving end , making and installing the top cover of the centrifugal machine , making an arm and installing it on the shaft of pug mill , making and installing scrubber and bottle jackets of sulfur f