Tender For tender for supply of fire detection and annunciation system - m call pt for indoor , m call pt for outdoor , multicriteria type smoke detectors , inteligent adrsable control oi3 module , zone ctrl card , mdl 600mw , intelligent addrsable zoneaim module , probe type heat detector , response indicator , loop hooter of fda system , display card of fda system , mcu card of fda system , ofc netwok card of fda system , loop card 600 mw , psu 6 pwr supply mod for fire alarm , listec controller of fda system , listec connnection box of fda system , listec connecting cable of fda system
Tender For bid to ras bid to ras supply of rrc for addressable fire detection system onboard in ships and yard crafts at nsry karwar -repairs to main control panel , repairs to repeater panel , repairs to control cards , repairs to ionization smoke detector , repairs to multi sensors , repairs to temperature heat detection sensor , repairs to flame detector , repairs to manual call point , repairs to front panel switches , repairs to alarm bells lights hooters , repairs to internal circuit wiring , repairs refurbishment of ups , repairs to cabling from main control panel , reprogramming of the pcbs
Tender For e-tender annual maintenance contract for maintenance of fire protection fire/ smoke/heat detector system available at 400kv/220kv koradi-1 substation under 400kv rs (o&m) division koradi
Tender For corrigendum : supply of supply of floor mounted direct radiography system with dual detector under buy-bcak policy floor mounted direct radiography system with dual detector floor mounted direct radiography system with dual detector:- 1.generator the generator should be high frequency capacity of 30 kw or more. kv range should be 40 kv- 125 kv or more. the output at 80 kv should be 400 ma or more. generator frequency should be 200khz or more 2. x-ray tube and collimator the x-ray tube should be of rotating anode with dual focus having the following sizes: (i) large focus: 1.5 mm or less. (ii) small focus: 0.6 mm or less the unit should have anode heat storage capacity of 100 khu or more. distance measuring scale should be provided. should have an multi-leaf collimator having bright light source auto shut provision for the light along with automatic image cropping facility. the light output should be minimum 160lux tube rotation on vertical axis should be - 180 degree locked (clockwise) & + 120 degree (anticlockwise) at least with end stopper. the tube column should be ceiling-free floor mounted and should have longitudinal travel of a minimum 1500mm. touch screen display on tube head to control kvp & mas as well as selection of body parts. 3. vertical detector stand the unit should be provided with vertical stand. the unit should have provision to do all upright x-rays. the vertical detector should travel from at least 1.4 ft to 5.5 ft above floor level. it should be flat vertical motion can be locked in any position. 4. table the table top should be floating with transverse and longitudinal movements 250 mm, 300 mm respectively or better. the table should have a weight bearing capacity of minimum 200 kg or more. the table should have anti scatter grid electromagnetic ) /bid number : gem/2026/b/7398823 * /dated: 28-03-2026 & & / bid document 1 / 8