Tender For supply of lab equipment for department of instrumentation and control engineering - i/p and p/i converter, pressure measurement using bourdon tube and lvdt setup, level measurement using float and sight glass indicator, temperature transmitter trainer kit, single phase transformer with load, saybolt viscometer, on off control of temperature process, flow measurement using electromagnetic flowmeter
Tender For purchase of lab equipments for ice dept - purchase of lab equipments for ice dept, i/p and p/i converter (iemcode:g002) i/p converter:(4 20) ma to (3 15) psi conversion. p/i converter:(3 15) psi to (4 20) ma conversion. air filter regulator (afr):20 psi regulated air supply. built-in current source. 3 digit led display for process indication. power supply: 230 v ac, 50 hz. mounting:bench-top / panel-mounted trainer configuration., level measurement using float and sight glass indicator- itemcode: g005specifications: sight glass level indicator. float type level indicator. power supply:230 v ac, 50 hz. monoblock pump:0.5 hp / 1 hp. sump tank., 8051develop ment board with usb/rs 232 cable to connect with computer (item code: g008)specifications: communication interface:usb / rs-232. on-board facilities:8 output leds,8 input switches,ldr,reed switch,8-bit adc,8-bit dac. display interfaces:seven-segment display,16 2 lcd interface. motor interfacing:stepper motor with driver,dc motor with h-bridge driver, 8 bit adc/dac interface board (item code: g009)specifications: thermistor / lm35 input in one channel. variable input (0 5) v in another channel. 8 leds for digital output indication.. necessary control signals provided for adc0809. 8-bit dac using dac0808. 8-bit digital input from controller. single-channel dac output:(0 10) v. power supply: 12 v or 15 v for analog circuitry, water level measurement trainer kit using capacitive type transducer (item code: g020) tabletop model with transparent acrylic tank of approximately 50 cm height. capacitive type level sensor for continuous level measurement. sensor output: (4 20) ma and/or (0 5) v with built-in signal conditioning. vertical pump for water circulation from sump to tank. flow control valve, overflow, and drainage arrangement. digital display for water level indication in cm. power supply: 230 v ac, 50 hz, single phase. in-built regulated dc power supply for sensor and control circuit. mounted on powder-coated ms frame for laboratory use. suitable for calibration and study of capacitive level measurement., flow measurement using electromagn etic flow meter(item code: g021)specifications: medium: water (salt water / bore well water). electromagnetic flow measurement: instantaneous flow rate and totalized flow indication. electromagnetic flow meter: integral mounted type. power supply: 90 260 v ac, 50 hz. minimum media conductivity: 15 s/cm. flow rate unit: m /hr. operating pressure: up to 10 kg/cm . electrode material: ss-304 / ss-316 / ss 316l. lining material: ptfe / neoprene / hard rubber / pfa. line size: 15 nb 25 nb. flow range: 0.1 10 m /hr. connection type: flanged. display: digital indication for flow rate and totalized flow. water pump: submersible type, 230 v ac, 50 hz. water tank: approximately 20 25 liters capacity. flow control valve provided. drain valve and overflow arrangement provided. mounted on powder-coated ms frame suitable for laboratory use.
Tender For purchase of renewable energy practical equipments - equipments for renewable energy practices:, rc phase shift oscillator oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram, strain guage characteristics kitac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristics kit input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer input supply: 230 v / 50 hz ac with regulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation. measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter input supply: 230 v / 50 hz ac with regulated internal dc supply unit. measurement principle: buoyancy (archimedes principle) using displacer element. tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement of temperature using pt100 input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath. measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to 150 c (or suitable laboratory range). display unit: digital temperature indicator with direct c display. accuracy: high accuracy with linearized rtd signal conditioning circuit. sign
Tender For purchase of lab equipments for res dept - purchase of lab equipments for res dept, rc phase shift oscillator (iemcode:o001)specifications: oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram., strain guage characteristi cs kit(iemcode:o002)specifications: ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. no rs.10,000 2 table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristi cs kit(item code: o003)specifications:input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer(item code: o004)specifications: input supply: 230 v / 50 hz ac withregulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter(item code: o005)specifications: input supply: 230 v / 50 hz acwith regulated internal dcsupply unit. measurement principle:buoyancy(archimedesprinciple) using displacerelement tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement oftemperature using pt100(item code: o006a)specifications: input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to
Tender For supply of metrology lab equipment - purchase of lab equipments, digital vernier caliper (0 - 150mm) specifications: measuring range: 0 200 mm least count / resolution: 0.01 mm accuracy: 0.02 mm material: hardened stainless steel measurement: outside, inside, and depth measurement display: digital lcd power supply: battery operated protection: ip54 or better make: reputed brand such as mitutoyo / insize / baker or equivalent, digital micrometer specifications: measuring range: 0 25 mm least count / resolution: 0.001 mm accuracy: 0.002 mm measuring faces: carbide tipped display: digital lcd repeatability: 0.001 mm protection: ip54 or better power supply: battery operated material: hardened stainless steel frame make: reputed brand such as mitutoyo / insize / baker or equivalent, pneumatic trainer board specifications: type: modular pneumatic training system working pressure: 2 8 bar components: frl unit with pressure gauge (0 10 bar) 3/2 valve 2 nos 5/2 dc valve 2 nos flow control valve 2 nos double acting cylinder 1 no single acting cylinder 1 no tubing: pu tubes with push fit connectors panel: rigid modular panel with mounting slots power supply: 24v dc (for solenoid valves) modular training panel with sturdy metal frame all cylinders, control valves, limit switches and other accessories should be kept separately and should not be fixed permanently in the board/ stand.
Tender For purchase of instrumentation and control engineering practices (equipment) - motorized control valve trainer kit signal input:4 20 ma or 0 5 v valve characteristic:equal percentage stem movement:maximum 10 mm or 12 mm body material:cast iron trim material:ss 316 trim size: cv value:2 or 5 actuator:servo motor supply voltage:230 v ac, 50 hz connection: flanged or screwed type. digital indicator provided potentiometer provided for varying the 4 20 ma input signal, saybolt viscometer apparatus glass type: high-quality borosilicate glass tube. control type: manual energy regulator control. shape: rectangular bath with cylindrical test chamber. temperature range: ambient to 240 c oil bath temperature. humidity: up to 80% rh (non-condensing). power supply: 230 v ac, 50 hz. measuring range: 32 to 1000 sus(saybolt universal seconds). accuracy: as per astm d-88( 0.2 seconds). mounting type:benchtop. capacity:one cup(approximately 60 ml). control mode:manual operation. port size:standard orifice sizeas per astm d-88. features:oil bath with heater,thermoregulator,insulated outer body,orifice,receiver flask, control valve trainer kit three pneumatic control valves provided with individual hand valves valve characteristics: i) quick opening ii) linear iii) equal percentage. valves connected in parallel configuration for comparative study. pneumatic operation with air supply connection. control valve assembly mounted on trainer panel. power supply: 230 v ac, 50 hz., water level measurement trainer kit using capacitive type transducer tabletop model with transparent acrylic tank of approximately 50 cm height. capacitive type level sensor for continuous level measurement. sensor output: (4 20)ma and/or (0 5)v with built-in signal conditioning. vertical pump for water circulation from sump to tank. flow control valve, overflow, and drainage arrangement. digital display for water level indication in cm. power supply: 230 v ac, 50 hz, single phase. in-built regulated dc power supply for sensor and control circuit. mounted on powder-coated ms frame for laboratory use. suitable for calibration and study of capacitive level measurement.
Tender For bid to ras corrigendum : supply of bi facial solar panel 550 watt , topcon solar panel 610 watt , cut section of gate valve,globe valve,ball valve,diapharm valve,needle valve,check valve,safety valve,butterfly valve,pnematic control valve 4 inch diameter , cut section of centrifugal pump,gear pump,multistage c f pump,reciprocating pump,screw pump , cut section of shell and tube heat exchanger acrylic material , cut section of reactor with accessories motor,agitatot,support leg,nozzle,manhole,baffels,thermo well,bottom valve , vrf or vrv unit with two indoor unit 2 point 5 tr each and 5 tr capacity out door unit complete with air cooled condenser,accessories and controls,harmetic shield type compresor,r410 a single phase , evacuating and charging station as above but fitted with weighing scale 0 point 25 hp,230v,50 hz with gauge manifold , gauge manifold with gauges different size of hoses for r134a,r22,r32 and r 410 , wash bag cover jacket for ac service indore 1 point 5 ton,2 point 5 ton capacity , safety belt, industrial type full body protection double rope double hook,100 kg human weight , embroidery machine , brake test arrangement with two spring balance 0 to 25 kg rating , automatic motor coil winding machine with step arbor , three phase variable auto transformer ac varic 3 phase , 0 to 440v, 25a, 50 hz , synchronous motor, with accessories , vfd ac drive ac motor drive with vvvf control 3 phase , single phase transformer, core type, air cooled,1 kva,240 or 415 v,50hz , stepper motor with digital controller , bipolar , 12v dc , input pulse 5v, step angle 1 point 8 , power supply 230 v ac , oprating condition 0 to 40 deg c , bldc motor fan with controller 40 watt , servo motor with contoller 300rpm,12v dc,6mm dia and 15mm legth shaft ,holding torque 30kg cm,no load current 0 point 8 amp,full load current 7 point 5 amp , electrical test bench integrated with 0 to270v ac variac 25a , synchronization trainer for laboratory , solid flow measurement set up bi facial solar panel 550 watt,efficiency 21.3 percentage,dimension 2285mm x 1134mm x 35 mm,anodized aluminumsilver frame,connector mc4 ev02,maximum system voltage 1500v dc, topcon solar panel 610 watt,efficiency 22 point 6 percent to 22 point 9 percent,n type topcon,dimension 2382x1134x30 mm,2 mm dual glass,maximum system voltage 1500v dc, cut section of gate valve,globe valve,ball valve,diapharm valve,needle valve,check valve,safety valve,butterfly valve,pnematic control valve 4 inch diameter, cut section of centrifugal pump,gear pump,multistage c f pump,reciprocating pump,screw pump, cut section of shell and tube heat exchanger acrylic material, cut section of reactor with accessories motor,agitatot,support leg,nozzle,manhole,baffels,thermo well,bottom valve, vrf or vrv unit with two indoor unit 2 point 5 tr each and 5 tr capacity out door unit complete with air cooled condenser,accessories and controls,harmetic shield type compresor,r410 a //bid details 2 / 25