Tender For auction sale of rolling stock - pl no.98111061, condemned bg-8 wheeler- icf ac coaches 3 nos, without bogie, with all available ferrous, non-ferrous-wooden fittings thereon but excluding the following reclaimable items. 1} coach no. special repair accn 056905 (year built 2005), ds-8 no. 334716 dt 31.03.26, mechanical rc items are common for all three coaches as per sse/c&w/srr letter dt 24.01.2026- 1] complete bogie arrangements including wheel sets 2 nos, 2] buffer plunger and casing 4 nos 3] cbc/screw coupling set [draw bar with hook, draft gear assembly] 2 sets, 4] center pivot 2 nos. 5] bogie mounted brake cylinder 4 nos, 6] distributor valve complete full set 1 set, 7] wearing piece( bronze) and plate 4 nos each, 8] auxiliary reservoir 200 l. 1 no 9] main doors -4 nos 10] cut off angle cock- 4 nos. 11] dirt collector- 2 nos 12] non return valve(fp)- 1 no. electrical rc items as per sse/electrical/srr /letter no.elg/srr/6a dt 23.01.2026- 1] alternator - 2 nos 2] regulator - 2 nos 3]vrla battery -56 nos. 4] tensioning device - 4 no 5] bldc fan 400 mm-8 nos. 6] 150mm fan- 4 nos 7] exhaust fan-04 nos 8]5 w led with fittings (double led)- 16 nos 9] 5 w led with fittings (single) - 5 nos 10] 2w led 8 nos 11] emergency light unit-3 nos 12] d type led fitting - 5 nos 13] md switch-32 nos 14] mobile charger - 16 nos 15] axle pulley -4 nos 16] pumb - 2 nos 17] pre cooling unit - 1 no 18] pre cooling socket -1 no 19] inverter panel- 2 units 20] power panel- 1 unit 21] rmpu- 2 units.. 2} coach no. special repair accn 056904 (year built 2005), ds-8 no. 334717 dt 31.03.26, electrical rc items as per sse/electrical/srr /letter no.elg/srr/6a dt 23.01.2026-1] alternator 25 kw - 2 nos 2] regulator - 2 nos 3] vrla battery -56 nos. 4] tensioning device - 4 no 5] inverter 2 nos 6] bldc fan -8 nos. 7] emergency light unit-2 nos 8] 150mm fan- 4 nos 9] exhaust fan-04 nos 10] 5 w led with fittings (double led)- 18 nos 11] 5 w led with fittings (single) - 1 no 12] 5 w led -5 nos 13] axle pulley -4 nos 14] pump - 2 nos 15] pre cooling unit -1 no 16] pre cooling socket - 2 nos 17] inverter panel -2 units 18]power panel- 1 unit 19] rmpu- 2 units.. 3} coach no. special repair accn 041198 (year built 2004), ds-8 no. 334718 dt 31.03.26, electrical rc items as per sse/electrical/srr /letter no.elg/srr/6a dt 23.01.2026-1] alternator - 2 nos 2] regulator - 2 nos 3]vrla battery -56 nos. 4] tensioning device - 4 no 5] inverter 2 nos 6] bldc fan -8 nos. 7] 150mm fan- 4 nos 8] exhaust fan-04 nos 9]5 w led with fittings (double led)- 18 nos 10] 5 w led with fittings (single) - 6 nos 11] d type 5 w led 2 nos 12] 2 w led-8 nos 13] md switch-32 nos 14] mobile charger - 8 nos 15] axle pulley -4 nos 16] pump - 2 nos 17] pre cooling unit - 1 no 18] pre cooling socket -2 nos 19] inverter panel- 2 units 20] power panel- 1 unit 21] rmpu- 2 units. custodian sse/ c&w/ shoranur.
Tender For resurfacing of tata sports complex grounds including irrigation system, borewell, reservoir and development works at iit kharagpur (west bengal). (pkg-2 : borewell, reservoir and development works)subwork/packages:preparation of structural drawing of rcc undergroundreservoir and pump house room.
Tender For procurement of spares for m and m tippers working at area workshop, mm area - tipping valve 3 dhmp 3/4 inch m, return line filter assy (plastic cap), breather filter element, seal, hose valve to cylinder, hose pump to valve, hose tank to pump 1 3/4 inch 1m, return line filter element, p.t valve 1220 assemble, pto for zf 9s7s 9s109 9s110, air breather assy, pvc flexible tube 20mm od, air tube od 6mmxid 4mm, gear pump 82l bi 4h, knock off valve assembly + accessories, inner seal part no 7005aap00031n, prop shaft with slip 25tt std bog part no 6901baq00161n, tie rod end assy-lh -mpn- 7503aap00100n, ball joint m10lh talbros - mpn-6702fap00031n, ball joint m10rh talbros - mpn-6702fap00021n, rubber hose assy, gasket axle shaft part no 7005bap00021n, tilting cylinder, repair air kit-dual brake valve -mpn-7718aap04570n, service kit- hand brake valve -mpn-7718aap04600n, service kit- quick release valve, service kit-inversion relay valve, service kit-relay valve, pump fuel injection-ve - mpn-0305hav00380n, pump to gearbox hose (zf) part no 7502cap00052n, gearbox to reservoir hose (zf) part no 7502cap00062n, bolt hex m18x2x245x10.9, nut nyloc m18x2x245x10.9, pto assy without quill shaft, minor repair kit-air compressor part no 7718aap04680n, major repair kit-air compressor part no 7718aap04650n, piston repair kit-air compressor, piston ring repair kit-air compressor, minor repair kit part no 7718aap00570n, major repair kit part no 7718aap00580n, flange yoke, uj kit part no 6903aap00020n, flange yoke part no 6903aaq00050n, uj kit part no 6903aaq00020n, slip yoke assembly part no 6903aaq00030n, tube shaft assembly part no 6903aaq00040n, clutch-disc-assembly-dia395, clutch cover assembly,dia395, rr-view-mirror-main-rh, rr-view-mirror-wide-angle, rr-view-mirror-main-lh, proximity mirror, clutch release fork - mpn-6802bap00070n, clutch release shaft lh part no 6802bap00080n, clutch release shaft rh part no 6802bap00090n, clutch release bearing assy, clutch release fork locking clip - mpn-6802bap00150n
Tender For corrigendum : repair/maintenance cleaning and sanitization underground/overhead reservoir/storage tank and other connected work at saa under ge (s) tezpur
Tender For cleaning of ug sump, oh reservoir, swt ug, repair to valve pit chamber, dozing pump and connected works of water supply system at af stn palam under ge af palam, delhi cantt-10
Tender For - procurement and supply of bis-certified water treatment chemicals for urban water supply (uws) schemes, namely alumina ferric (grade-iv conforming to is: 299:2012, fifth revision with latest amendments) and hydrated lime grade-i, along with dosing of chlorine dioxide solution prepared at 10,000 ppm concentration (using scs 10k, 1% chlorine dioxide powder) directly into the undergroundreservoirs for disinfection of drinking water at swtp melaghar under the jurisdiction of dws sub-division, melaghar during the year 2026–27 (gr–i).