Get complete information related to latest Universal Counter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Universal Counter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Universal Counter Tenders.
Tender For supplying installation testing and commissioning of laundry equipment in ashadeep narela delhi - supplying installation testing and commissioning of laundry equipment in ashadeep narela delhi - sitc of front loading washing machine with loading capacity of 30 kg dry weight per charge heavy duty , electrically heater inner basket & outer drum stainless steel, micro countroller base cyclic timer for auto- reserve, auto- timer & auto digital temperature control, water- inlet valve drain valve complete with control panel, & electric motor for wash, driver through pulleys & v- belts and control panel operator on 3ph, 415 v, 50 hz, a.c. supply operation cycle 30 to 40 mintutes complete connection etc as required, sitc of hydro extractor machine direct- driver self- balance with automatic electromangnetic dc injection brake system having capaciy of 30 kg per charge with auto -timed top loading vibration less innner basket and outer drum stainless steel complete with specially designed electric motor and control panel operator on 415 v,3 phase , 50 hz ac supply . operation cycle 5 to 10 mintes complete connection etc as required., sitc of drying tumbler machine front loading open pocket, electrically heater with loading capacity of 30 kg . per charge complete with micro controller base cyclic timer for auto timed & auto - reserver, auto digital temperature control, fitted with control panel , one motor each for driver and blower double walled glass wool insulated outer body mild steel with inner basket stainless steel, self lint screen , v belt driver waster air exhaust etc operates on 415 v, phase 50 hz ac supply . operation cycle 40 to 60 mintes complete connection etc as reqd, supplying and drawing following sizes of frls/hffr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required.a) 3 x 4 sq. mm, b) 6 x 4 sq. mm, supplying and fixing of following capacity, 240/415 volts, 10ka/15ka c series mcbs suitable for lighting and other loads of following poles in the existing mcb db complete with connection, testing and commissioning etc as reqd.a) 40a, 10 ka , fp mcb (415v), b) 63a, 10 ka , fp mcb (415v), supplying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size complete as required.a) 4x 16 sqmm, b) 4x 25 sqmm, supplying, installation, testing & commissioning of led surface mounted batten light of following body material and construction as per is : 10322 with driver (replaceable) as per the requirement with driver efficiency >85%, operating voltage ac 140- 270 volt, frequency 50/60 hz, operating temp range -5 c to 40 c, internal surge protection of 2.5 kv with short & open circuit protection, thd 10%, p. f. 0.95, ip20, cri >80, flicker free, (flicker shouldbe below 5 %), life time (led, driver & electrical circuitry), of minimum 50000 burning hours with 70% of initial lumen maintained till life ends, cct 3000 k / 4000 k / 5700 k /6500 k (as per ansi bin), sdcm(standard deviation colour matching) 3, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard. manufactures word mark/ name engraved/ embossing/ screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy 105 120 lm/watt output . lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90 c). powder coated die cast /extruded aluminium body (thickness > 1.20 mm)a) 40 watt, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in th
Tender For corrigendum : ca no. ge af no.1/gur-76/2025-26 provn of centralised temperature controlling system at std cal lab at 13 brd, provn of high mast light at stc area at 54 asp and other minor works at 54 asp af and 27 ed under ge (af) gurgaon no 1
Tender For tggenco btps stage ii i and c division removing cleaning testing and refixing of solenoids pressure transmitters vacuum transmitters pressure switches multi sensor detectors manual call points heat detectors ir flame detectors deluge valves motor operated valves analyzers chlorine leak detectors temperature gauges temperature elements rtds rio panels plcs of chlorination plant clarifier pump house plant water system effluent treatment plant(etp) foam pump house hydrant booster pump house ac plant diesel generator set fire detection system sewage treatment plant inert gas system steam water analysis system of unit 3 and 4 for the fy 2026 27
Tender For armo residential and non residential buildings of lhmc & ah, new delhi during 2025-26. sub head:- providing and fixing wireless busbar temperature monitorig system at ess-i
Tender For corrigendum : procurement of low temperature moisture separation system (shell and tube heat exchanger and csystem) for development of condensate removal system (dehydration system) and the associated facilities