Get complete information related to latest Ups Battery Bank Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ups Battery Bank Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ups Battery Bank Tenders.
Tender For the detail of works includes:a. the tenderer shall carryout the following works during annual maintenance contract period along with the servicing of the diesel generator set.1. general checkup & preventive maintenance and to fill up preventive checkup schedule as follows:a) check lube oil level and conditioning of lube oil, top up/refill if required.b) the oil filters shall be replaced whenever oil is changed.c) the air filters shall be cleaned periodically with compressed air, check batteries and top up the distilled water if required.d) check functioning of changing alternator.e) engine safety viz. high water temperature gauge, oil temperature gauge and high speed gauge shall be checked for their functions and repaired/replaced if required.f) coolant level and conditioning of coolant shall be checked and refilled if required.g) check fan and alternator drive belts and tightened if required.h) the governor shall be checked and tuned for proper functioning.i) check for leaks if any and shall be rectified.j) check reports shall be submitted every month/every breakdown calls.2. checking and servicing of engine for smooth running, its unusual sound and color of smoke and exhaust and set it right in case of deviations.3. checking and repairing and leakage of fuel, lubricating oil and coolant.4. cleaning and changing of air filters as per requirement.5. setting of valves tappets whenever required.6. checking and repairing of accessories drive, turbo charger and crankshaft endplay whenever required.7. checking of alignment of engine & alternator as per requirement.8. checking of throttle control and its setting.9. checking of instrument panel including replacement as and when required.10. checking of rotating diodes assembly in brushless alternator including replacement as and when required.11. checking of wiring system and repairing/replacement as and when required.12. repair and maintenance of relays including contractors in control panel.13. checking of battery terminal and de-sulphating.14. diagnosis of faults in engine and alternator and its rectification.15. breakdown calls to be attended on priority within 6 hrs.16. providing spare avrs, self-starter and accessories, free of charge, if the repair/overhaul/replacement is expected to be taken in more than two days.17. checking/repair/adjustment/replacement/servicing shall be carried under annual maintenance contract except cost of component/parts to be replaced due to wear & tear.18. the firm should undertake to arrange genuine spares of the diesel engine, alternator and amf panel as and when required within two working days.19. the tenderer’s service engineer shall visit the site for attending the generator sets not less than twelve times during the contract period (minimum once in a month) and shall inspect the generator set thoroughly. each visit shall take place during 1st week of each month.20. the tenderer’s service engineer shall visit once in two month for checking of electrical side viz. alternator, amf control panel, if any.21. the engine shall be run on no load or at available load, and should be checked for any leakage and abnormal noise. if any such abnormality noticed shall be diagnosed and remedial action shall be taken.22. standard check list:a) replace minor parts (i.e hoses and filters etc) sub-assemblies as and when required.b) service engineers during the visit will report on the performance or any other abnormality and inform parts requirement. he shall also submit the report on work done and recommendations as well as spare parts required.c) attend emergency call on priority (usually same day). however, if the engineer is required or any particular date and time, it would be the responsibility of the customer to intimate the contractor in advance.d) major overhauling/ top overhauling / pt pump & injector calibration /replacement of major parts/ rewinding of alternator or repairs or breakdown of the diesel generator set are to be charge
Tender For supply of maintenance free valve regulated lead acid (vrla) battery set for 110 volt system 70 ah consisting of 09 modules of 12 volt each, suitable for lhb coach as per rdso specification no. rdso/pe/spec/ac/0009- 2014 (rev.-2) and str no. rdso/pe/str/tl/0014-2010 (rev.-1) with amdt. no.1& 2, complete with inter unit connecting cables. [ warranty period: 30 months after the date of delivery ]
Tender For supply of sealed maintenance free battery, vrla, 120 ah with inter cell and end cell connector conforming to rdso's specification no. rdso/pe/spec/ac/0009-2021 (rev.2) (one sets consist of 19 monoblock battery of 6 volts) [ warranty period: 30 months after the date of delivery ]
Tender For armo of gpra complex at ashiana digha road, rajeev nagar patna. (sh - supply, installation, testing and commissioning of maintenance - free lead acid battery (12v, 18ah and 4.5ah) for otis liftsubwork/packages:sitc of maintenance - free lead acid battery (12v, 18ah and 4.5 ah) for otis lift
Tender For corrigendum : supply of various types of consumable items and miscellaneous items for day to day maintenance works for emd-6 utps. (emd-6 et-6203) - carbon cleaner spray, puff seal have polyurethene based foam sealing compound, stanvac pen oil rust remover 6030,500 ml/pac, 6084 red insulating varnish (500 ml) can, 901 easyclean (nf) 500 ml. spray can - on line electrical contact cleaner., 415v offline contact cleaner (700ml tin), z955 (sl) srippex sltape roll (silicon rubber, self amalgamating, high temperature resistance tape size:-25mmw0.50mmw15mtr./roll, feeler gauge: 0.05 - 1 mm, length - 150. size: 0.05 - 1mm step of 0.05mm, 20 leaves, self expanding cfc free one component polyurethane foam sealant. product2206 360 puf 3x in 700 ml spray can., w963 play safe high voltage tape (50 mm x 0.76 mm x 9.1 mtr) roll, w963 play safe high voltage tape (25 mm x 0.76 mm x 9.1 mtr) roll, self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of green colour, ht pvc insulation tape size 0.18 mm x25 mm x 65 mtr length, temperature measurement laser gun., araldite 180 gram/tube, z 801 fast steel epoxy stick (1 stick 114 grm), emery cloth roll 50mm w x 50 mtr grit 220 extra fine, cable tie 100 mm, cable tie 150 mm, cable tie 200 mm, impact wrench power/battery operated, taparia make utility knife. product no. uk-3., cordless screw driver power/battery operated, tools bag (taad patri type, thick cloth) with 3 to 4 pockets for artisian tools having size 16" x 4" x 10"approximate, weighing scale digital, crc-226 contact cleaner in 415 ml/300 gram spray bottle., wd -40 industrial 420 ml wd 40 spray bottle for rust removing purpose, hss ground thread hand tap set m 10x1, nylon braided pvc hose pipe suitable air/water handling ;at working pressure of 10kg/cm2 ,size; 12mm, molykote 1000 spray can (400ml/270gms/can), electrically operated angle grinder, size: 100 mm, model no:gws 6-100 g,p no: f002 g30 050, make: bosch, digital multimeter 4.1/2 digit (true rms), loctite 242 thred locking 250 ml/tube, 2 tb external usb powered hard disk, pebble ral 7032 color spray bottle for electrical ht / lt panel, high voltage detector, rubber hand gloves, long rang rechargeable torch with charger., ag-4 cutting wheel make:bosch, buffing wheel , size: 100 x 16 x 5/6 mm, circlip plier pvc dip coated sleeve , internal (straight nose type ) ,cap 19mm to 60mm, 185mm length, product no.1441-7n, external circlip plier ( straight nose type ) cap 8 mm to 25 mm.product no:1443-5s, hss ground thread hand tap set m 4x0.7, hss ground thread hand tap set m 5x0.8, hss ground thread hand tap set m 6x1, hss ground thread hand tap set m 8x1.25, hss ground thread hand tap set m 10x1.5, hss ground thread hand tap set m 12x1.75, hss ground thread hand tap set m 14x1.5, digital ma clamp on meter