Get complete information related to latest Upvc Pipe Line Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Upvc Pipe Line Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Upvc Pipe Line Tenders.
Tender For corrigendum : construction of pump house ,sinking of big dia tube well, boundary wall, interconnection, laying distribution of upvcpipeline and iep with blower room at 3rd tube well site of sultannagar piped water supply scheme at harishchandrapur-ii block of ma
Tender For corrigendum : sinking of big dia. tube well, construction of pump house, inter connection, boundary wall and laying distribution of upvcpipeline at 4th tube well site of hatinda piped water supply scheme at chanchal-i block of malda district under malda division
Tender For corrigendum : additional upvcpipeline for improvement of functionality, providing balance functional house connection, road restoration, land development and pathway at head work site, rectification of fhtc of sanjail piped water supply scheme under malda divis
Tender For corrigendum : dedicated pipe lying distribution of upvcpipeline of arbara piped water supply scheme at chanchal-i block of malda district under malda division, phe dte, govt. of west bengal.
Tender For corrigendum : annual rate contract of instrument maintenance jobs for the year 2025-26 - removing of level gauges, fixing of level gauges, transportation of level gauges, removing of level switches, fixing of level switches, removing of leveltrols, fixing of leveltrols, transportation of leveltrols, removal of differential pressure/ pressure transmitter with or without capillary with flange size upto 80mm and upto 600# rating, diaphragm seal type transmitter, ordinary transmitter, fixing of differential pressure/ pressure transmitter with or without capillary, diaphragm seal type transmitter, ordinary transmitter, fixing of differential pressure/ pressure transmitter with or without capillary, diaphragm seal type transmitter, ordinary transmitter, removal of diaphragm seal type pressure/d.p gauges with flange size upto 80mm and upto 600# rating, fixing of diaphragm seal type pressure gauges with flange size upto 80mm and upto 600# rating, transportation of diaphragm seal type pressure gauges / ordinary pressure gauges, removal of pressure switch, installaltion of pressure switch, removal of glass tube type rotameter, removal of magnetic type rotameter, fixing of glass tube type rotameter, fixing of magnetic type rotameter, transportation of rotameters (any type), removal of different type of flow meters, upto and including 4" size irrespective of pr. rating, above 4" size irrespective of pr. rating, fixing of different type of flow meters, upto and including 4" size irrespective of pr. rating, above 4" size irrespective of pr. rating, transportation of different types of flowmeters irrespective of size & pr rating, removal of orifice plate from flange assembly, upto & including 6" line size (of any rating) ., more than 6" line size (of any rating), fixing of orifice plate at flange assemply, upto & including 6" line size (of any rating) ., more than 6" line size (of any rating), removal of power cylinders, size upto 4" dia, size > 4" dia, mounting of power cylinders., size upto 4" dia, size > 4" dia, transportation of power cylinders, shifting of empty or filled calibration gas cylinders, removal of thermowells alongwith thermocouple, removal of thermocouple without thermowells, fixing of thermowells alongwith thermocouple, fixing of thermocouple without thermowell, removal of weep hole probes of urea reactor, fixing of weep hole probes of urea reactor, laying of tubing., size 6/8mm of copper or ss tube, size 10/12mm of copper or ss tube, removal of tubing, size 6/8mm of copper or ss tube, size 10/12mm of copper or ss tube, laying of gi pipe., upto size 1/2", > 1/2" , upto size 1", > 1" , upto size 2", > 2" , upto size 4", fabriction & laying of impulse lines/air header etc. of following sizes of pipes (non ibr) including welding upto sch 40, upto & including 1/2" carbon steel, upto & including 1/2" stainless steel/alloy steel, > 1/2" upto & including size 1" carbon steel, > 1/2" upto & including size 1" stainless steel/alloy steel, > 1" upto & including size 2" carbon steel, > 1" upto & including size 2" stainless steel/alloy steel, > 2" upto and including size 4" stainless steel/alloy steel, fabriction & laying of impulse lines/air header etc. of following sizes of pipes (non ibr) including welding more than sch 40, upto & including 1/2" carbon steel, upto & including 1/2" stainless steel/alloy steel, > 1/2" upto & including size 1" carbon steel, > 1/2" upto & including size 1" stainless steel/alloy steel, > 1" upto & including size 2" carbon steel, > 1" upto & including size 2" stainless steel/alloy steel, fabriction & laying of impulse lines/air header etc. of upto & including 1/2" carbon steel of pipes (ibr) more than sch 40, removal of impulse line/air header of ibr/non-ibr (for all ratings), size upto & including 1/2" of carbon steel/gi, size > 1/2" upto & including 1" of carbon steel/gi, size > 1" upto & including 2" of carbon steel
Tender For replacing deteriorated c.i. down take soil, waste and antisyphonage pipelines with upvcpipelines of buildings n,o, and p at parel staff quarters.
Tender For construction of 05 (five) nos street stand post, laying 90 mm (od) upvcpipeline and allied work under onda water supply scheme under bankura sadar sub-division of bankura division, p.h.e. dte.
Tender For shifting of pac units from jaisalmer to sardarpura and basni jodhpur - supplying of 0.63mm thick gss sheet , supplying of 0.80mm thick gss sheet , supplying of 1.00mm thick gss sheet , sitc of gi volume control damper , supplying and fixing of powder coated extruded aluminium return air grills with louvers , supplying and fixing of 4x16 sqmm power cable , supplying and fixing of control cable of 3x2,5sqmm , sitc of 40mm upvcpipe , sitc of 20mm upvcpipe , sitc ms cable tray 100mm width x 50mm x 1.6mm thickness , sitc ms cable tray 150mm width x 50mm x 1.6mm thickness , sitc of gi strip for loop earthing , dismantling and removing the existing laid old power or control cables , dismantling the existing old package units , recovering the existing laid refrigerant piping of old defective , dismantling the existing old ducts of package units , transportation of the existing fitted old dissmantled package a.c. units , itc of 7 tr sensible high precision ac package unit , supplying and charging of the referigerant gas r-407 , supply and fixing liquid line filter drier , supply and fixing of size 1-1 by 8 inch and 18 gauge copper referigerant pipe , supply and fixing of size 7 by 8 inch and 18 gauge copper referigerant pipe , supply and fixing of size 5 by 8 inch and 18 gauge copper referigerant pipe , laying of 1-1 by 8 inch recovered copper referigent pipe , laying of 7 by 8 inch recovered copper referigent pipe , laying of 5 by 8 inch recovered copper referigent pipe , providing ms structure for outdoor or indoor units , itc of 100mm width x 50mm x 1.6mm , itc of 150mm width x 50mm x 1.6mm , itc of old recovered 4x10 sqmm cable , itc of old recovered 4x1.5 sqmm cable , laying of existing 25 mm x 5 mm thick g.i. strip
Tender For corrigendum : supply, installation and commissioning of upvcpipeline and fittings (sch-80) at chlorination absorption system with pump and motor compatible with existing chlorination plant of unit.no.3 and 4 at sikka tps