Get complete information related to latest Uretherorenoscope Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Uretherorenoscope Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Uretherorenoscope Tenders.
Tender For rate contract for medicine - stainless steel abdominal hysterectomy set, n.s.v set (s.s), g.v set, self abdominal detractor, m.t.p set., vaccine carrier (small size), x-ray digitalisation with high-end cr system (with installation & 1 yers. warrenty) console software with mulitmodality work station the cr system should have advances workstation provided with 17" high resolution monitor, keyboard & ouse, with the fol., digital ultrasound machine colour dopler (high resolution ) with 4 probe, semi auto analyzer, fully automated bio-chemistry analyzertechnical specificationsthroughput-150t/hr (constant with both mono and double reagent)system function-random access/stat/batchtest method-end point, fix time, kinetic, (single/double reagents chemistry, mono/ bio-chromatic measurements)calculation methods-1 point linear, 2 point linear, exponential, logit log3p, logit log 4 p, logit log 5p, spline, line graph, k factorblank-reagent blank, sample blank, pre sample blank, pre reagent blanksample tray-40 position, sample volume :2-30 ui, 0.1 ul increment, micro cup, & test tube can be used for samplereagent tray-80 position, reagent volume: 20-300 ul, 1 ul incrementmixing system-teflon coated mixersample probe-1 needle with liquid detector, shock sensoroptics-halogen-tungsten lamp, absorbance range: 0-4.0 abs resolution: 0.0001 abs.diffraction photometry with wave length: 340, 405, 450, 505, 546, 578, 630, 700nm & 4 more optionswash station-12 step washing, 4 needle wash station, 1 dry pad, external needle cleaningcalibration-linear and non-linearqc-multi-level qc setup with levy-jennings graph and westgrads multi rules with mean sd, and cvwater consumption-not more than 6l/hrtemperature-reagent: 2-14 c (24 hr refrigeration), reaction cuvette: 37c 0.1 humidity- 80%system interface-usbpower requirement-ac 220v 10%, 50/60 hzdimensions-750 mm*560mm*530mm, hotair oven, binocular microscope (olampus), centri fuge machin (good quality), micropipette (0-50 microliter), micropipette (0-500 microliter), micropipette (0-1000 microliter), microtips (0-50 microliter), microtips (0-1000 microliter), bed side screen with cloth 1"round pipe with wheel, sponge holding (all size), artery forceps 6" curved, artery forceps 6" straight., artery forceps 8" curved, artery forceps 8" straight., artery forceps 4" straight., alliys tissue forcep (all size curved straight), mosquito forcep (all size curved straight), scissor 6 " curved (all size), scissor 6 " straight (all size), scissor mosquito straight. (all size curved, straight), diatheromy (machine), laparoscopic instrument full set (best quality), needle holder 8 "curved, needle holder 8 " straight, needle holder 6 "curved, needle holder 6 " straight, needle holder 4 "curved, needle holder 4 " straight, doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside, elisa reader with washer mechine with printer & ups., doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside ( best quality), fully automated chemiluminescence analyzer(clia) 1. system should be fully automated walk -away with continuous loading facility.2. analyzer should have able to perform thyroid, bone, cardiac, fertility, diabetes and anemia profile test.3. working principle of system should be micron super paramagnetic particles platform with alp labeled reagents and amppd substrate.4. must have 3 phase magnetic separation with precisely controlled temperature.5. analyzer should have photon counting detection mode with photomultiplier photo counter with led reference module.6. the analyzer must have vortex non-touch mixing which can reduce carryover., 7. throughput of the system should be more than 180 tests in a hour.8. system should have 15 reagents onboard with onboard 2 -8 nonstop refrigeration facility 9. system should have at least 50 sample positions and continuous loading facility.10. system should have continuous reagent
Tender For bid to ras providing of design installation and maintenance of educational lab/centre - science lab; site preparation, supply and installation of hardware, maintenance of hardware (amc/cmc), lab equipments; buyer,design installation and maintenance of educational lab/centre - smart class lab; site preparation, supply and installation of hardware, maintenance of hardware (amc/cmc), furniture, smart class; buyer,design installation and maintenance of educational lab/centre - ict lab; site preparation, supply and installation of hardware, maintenance of hardware (amc/cmc), mfm machine; buyer,design installation and maintenance of educational lab/centre - ict lab; site preparation, supply and installation of hardware, maintenance of hardware (amc/cmc), computers; buyer,design installation and maintenance of educational lab/centre - ict lab; site preparation, supply and installation of hardware, maintenance of hardware (amc/cmc), diesel generator set and ro; buyer -uv-vis spectrophotometer laminar air flow autoanalyser , elisa reader & elisa plate deep freezer(-20 c) fluorescence microscope 02 & co2 gas analyser fume hood , hysteresis loop hall effect polymer white microcentrifuge 12500 rpm calorimeter digital turbidity meter cod digester advance rotary microtome single phase stefans boltzmann law ,advance rotary microtome single phase stefans boltzmann law freezing point apparatus melting point centrifugal machine tlc complete set hot plate with magnetic stirrer water distillation , digital muffle furnace soxhlet apparatus refrigerator digital analytical balance fet characteristics apparatus charecterestic of scr study and verification of and, nand, xor, nor gate (complete kit
Tender For corrigendum : supply of chemicals, reagents & consumables for blood centre - fruit juice for blood donors 200 ml, evolis conductive tips 300 ul- 1 tip., evolis conductive tips 1100 ul- 1 tip., deep freezer -80 degree, deep freezer -40 degree celsius, data logar multi channel, thermograph marker pens, steel trays, smiley balls, plastic multipurpose box, bulbs & cuffs for aneroid b.p apparatus (big ben), weighing machine - adult, vdrl slide rotator, table top laboratory centrifuge, spygmomanometer b.p apparatus) (aneroid), serological water bath, rh viewing box, refrigerators with in built temperature monitor - 360 l, portable autoclave 350 x 325 mm dia, photo electric colorimeter, ph meter with accessories, multichannel micro pipette volume range 40-500ul microlitere, micropipette adjustable volume range 100-1000ul, micro pipette adjustable controller volume range 20- 200 ul microlitre (imported), micro pipette adjustable controller volume range 10- 100 ul microlitre (imported), interval timer electric, insulated containers for transporting blood bags between 2 degree celsius c to 6 degree celsius c (capacity 2-3 bags), incubator with thermos tatic control, hot air oven, high precision electronic weighing balance, hemoglobinometer, donor bleeding couch, domestic refrigerators 300 ltrs, data loggers for temperature recording, calibrated laboratory thermometer, blood bank refrigerator 600 l, blood bank refrigerator (50bags capacity)., binocular microscope with built in illumination, bar code stickers, bar code reader, micro slides 1 x100 slides- 1 box, glass test tubes 7ml capacity 12x100mm, glass test tubes 5ml capacity 12x75mm, glass test tubes 5cm x0.5 cm( borosil), glass test tubes 10cm x1 cm( borosil), glass test tubes 7cmx1 cm (borosil), wash bottle (500ml ), wafers for sterile connecting device, transfer bags, tissue paper -1 roll, thermal indicators, test tube cleaning brushes, steel trays with lid, steel test tubes stands with 30 holes 5 cm x 1 cm, stainless steel scissors straight 10 cms, portable trolley for shifting things in camps, portable trolley bags, plastic trays, plastic test tube stand with 50 holes, plastic test tubes stands with 40 holes 10 cmx 1 cm, plastic test tubes stands with 30 holes 7 cm x 1 cm, plastic bowls 8inches & 12inches diam, plain plastic disposable test tubes 5 ml, plain disposable test tubes 5 ml non vaccum red cap, plain disposable test tubes 3 ml non vaccum red cap, microtips blue (0.2 - 1ml) disposable, micro tips yellow ( 20-200 micro litre) disposable, labolene -500 ml -bottle, k2 edta non vaccum tubes 2 ml, k2 edta vaccum tubes 2 ml, insulated containers for carrying 50 blood bags (camps), handy plast (round 2 cms diameter ), disposable pasteur pipettes 5 ml, disposable pasteur pipettes 2 ml, color coded labels for blood bank, chart pen, chart paper for 7 day chart recorder for -40 deep freezer (terumopenpol), chart paper for 7 day chart recorder for - 80degree celsiusdeep freezer (terumo penpol), chart paper for 7 day chart recorder for 2 degree celsius to 6 degree celsius c blood bank refrigerator (terumo penpol), carbonised sample tips 300 ul, carbonised reagent tips 1100 ul, carbon brushes for table top laboratory centrifuge., camp cots, bullet vials 1.5ml with safe cap lock, bulbs for microscope 6 v 20 w, blood collecting triple bags (totm) 450 ml, blood collecting single bags 350 ml, blood collecting bag pediatric 100 ml, blood collecting triple bags 450 ml, blood collecting triple bags 350 ml, blood collecting double bags 450 ml, blood collecting double bags 350 ml, blood collecting quadruple bags for cryo precipitate 450 ml, artery forceps, syphilis elisa kit 4th generation (96/kit)-1kit, syphilis elisa kit 3rd generation (96/kit)-1kit, syphilis cards- 1 test, malaria p. f. / p v cards-1 test, malaria elisa (96 t kit)- 1 kit, hiv rapid kits-1 test /card, hiv elisa kit 4th generation (96t/kit)- 1 kit, hcv elisa kit 4th generation (96/kit)-1kit, hcv elisa kit 3rd gen