Get complete information related to latest Urine Bag Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Urine Bag Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Urine Bag Tenders.
Tender For the supply and installation of equipments to the blood bank of mims teching hospital mandya - mims-1-ultra deep freezer - 80c , mims-1-walk-in cooler , mims-1-vein viewer , mims-1-05 partcell counter , mims-1-refrigerated centrifuge floor model 16 bags , mims-1-blood component extractor , mims-1-fully automated apharesis machine for therapeutic procedure
Tender For supply of srphc82644035-triple blood bag cpd-sagm 450ml.it should have 450ml capacity with 63ml cpd solution and is connected to one satellite transfer bag of 450ml capacity andone satellite transfer bag of 450 ml with 100 ml sagm.needle should be 16g with triple bevel design to reduce penetration force and enable painless vein puncture.mother bag should be with good quality to prevent breakage during centrifugation andthe inner diameter of the tubes should be with good quality to provide easy flow of the component.blood bags should have hot markings in all tubes of the transfer bags. tubes of plasma, platelet and red cell should have hot marking numbers to ensure traceability. should be made of pvc with plasticizer approved as per indian pharmacopoeia/dcgi.the transfer bag for platelet collection should contain plasticizer compatible forstorage of platelets upto 5 days.blood bags and its packing should be properly labeled with batch. no., date of mfg., and date of expiry. product labels should be barcoded as per isbt-128.secondary packing and shipping cartons should be barcoded as per gs1-128 bags should be packed in an outer cover with sufficient barrier properties toprevent moisture loss during storage.the plastics container and the anticoagulant/additive solution shall have been sterilized by steam sterilization or any other validatedmethod.the method of sterlization used shall not adbersely affect the materials or contents ,nor cause any loosening of joints and deterioration of welds in the plastics material nor any major alteration in the shape of the plastics container.blood bags must conform to iso 3826 and indian pharmacopoeia for container,design,plastic(physical,chemical,biological)anticoagulant,labels,and needle.needle must conform to iso 1135-3.proof of compliance with iso 3826 and iso 1135-3 should be submitted bycompany.market standing of more than 05 years. donor tube is provided with luer adapter for online withdrawal of blood samples without contamination.needle injury protector,predonation bag are also provided to ensure more safety.[quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of d cfa re 30 ostomy synthetic skin barrier and microporus tape with centre point block flange and drainable pouch with transparent opaque odour barrier film and belt tab with stominal clamp 70 mm , d cfa re 30 ostomy paste 57 gms for use as skin barrier in fistula and ostomy cases , d cfa re 30 ostomy powder 28 gm , d cfa re 30 ostomy wound drainage collector for wounds up to 10 cm with odour barrier film excess cap synthetic skin barrier , d cfa re 30 ostomy wound drainage collector for wound up to 7 dot 6 cm with odour barrier film excess cap synthetic skin barrier , d cfa re 30 ostomy colostomy bags with microporous adhesive tape stominal one piece system , d cfa re 30 ostomy ileostomy bag with skin barrier stominal one piece system , d cfa re 30 suspensory scrotal , d cfa re 30 linear cutter reload unit blue cartidge for use with safety lock out 75 mm , d cfa re 30 polyamide monofilament size 2 0 70 80 cm 3 8 circle reverse cutting 40 45 mm , d cfa re 30 polydioxanone size 4 0 70 75 cm 1 2 circle rb needle 12 15 mm , d cfa re 30 polyamide monofilament size 3 0 70 80 cm 3 8 circle reverse cutting 25 30 mm , d cfa re 30 polyamide monofilament size 4 0 40 50 cm 3 8 circle cutting 15 20 mm , d cfa re 30 polydioxanone size 3 0 70 75 cm 1 2 circle rb 20 25 mm , d cfa re 30 polypropylene blue monofilament 70 75 cm size 3 0 3 8 circle rb 13 25 mm , d cfa re 30 polypropylene blue monofilament 70 75 cm size 3 0 3 8 circle reverse cutting 12 mm , d cfa re 30 polypropylene blue monofilament 70 75 cm size 4 0 1 2 circle rb 25 mm double needle , d cfa re 30 polypropylene blue monofilament 70 75 cm size 4 0 3 8 circle rb 13 25 mm double needle , d cfa re 30 synthetic absorbable polygalactin 910 polyglycolic acid coated with polycaprolate size 4 0 70 90 cm 1 2 circle rb 16 20 mm , d cfa re 30 u drain male incontinence device made of soft light weight latex sheath size small 25 mm dot , d cfa re 30 personal protective equipment ppe extra large size , d cfa re 30 protective goggles reusable , d cfa re 30 blood sedimentation rate pipette westergren graduated from 0 200 mm in 1 mm divisions dot , d cfa re 30 disposable lancet for finger prick pkt of 100 , d cfa re 30 replaces glass cover microscopic rectangular pv 16442 22x50 mm made of usp no 1 glass pkt of 14 gm , d cfa re 30 micropipettes fixed volume 500ul , d cfa re 30 dispo karman cannula size 4 , d cfa re 30 dispo karman cannula size 5 , d cfa re 30 dispo karman cannula size 6 , d cfa re 30 dispo karman cannula size 8 , d cfa re 30 walker adjustable and foldable , d cfa re 30 disposable plastic apron for arthroscopy surgery //bid details 2 / 31
Tender For corrigendum : purchase of surgical items and sutures at bundi - surgical and sutures, absorbable gelatin sponge ip 66, size 80(+-10) mm x 50 mm x 10 mm should be sterlized., asepto syringe with transparent bulb sterile, 60 ml, blood administration set / blood transfusion set sharp and easy piercing spike suitable for blood bags and standard blood containers transparent cylindrical drip chamber with filter.filter size should be 200+20 micrometer. 150 cm long smooth kink resistant tubing efficient roller clamp to control and adjust the transfusion rate should conform to is 9824(part 3):1996, disposable sterile surgical rubber gloves size 6 inches made of natural rubber latex, powdered, without tear, properly folded in a paper free of holes, with acceptable quality level (aql) of 1.5 or less tensile strength as per en 455-2 powder should be non-allergenic should conform to is 13422 isi marked / ce certified / fda approved, disposable sterile surgical rubber gloves size 6 inches made of natural rubber latex, powder free (polymer /silicon coated), without tear, properly folded in a paper free of holes, with acceptable quality level (aql) of 1.5 or less tensile strength as per en 455-2 should conform to is 13422isi marked / ce certified / fda approved (ce certification / fda approval for item is mandatory for importer firms, that cannot avail is standards), disposable sterile surgical rubber gloves size 7 inches made of natural rubber latex, powdered,,without tear, properly folded in a paper free of holes, with acceptable quality level (aql) of 1.5 or less tensile strength as per en 455-2 powder should be non-allergenic should conform to is 13422 isi marked / ce certified / fda approved, disposable sterile surgical rubber gloves size 7 inches made of natural rubber latex, powder free (polymer /silicon coated), without tear, properly folded in a paper free of holes, with acceptable quality level (aql) of 1.5 or less tensile strength as per en 455-2 should conform to is 13422isi marked / ce certified / fda approved (ce certification / fda approval for item is mandatory for importer firms, that cannot avail is standards), disposable sterile surgical rubber gloves size 7 inches made of natural rubber latex, powdered, without tear, properly folded in a paper free of holes, with acceptable quality level (aql) of 1.5 or less tensile strength as per en 455-2 powder should be non-allergenic should conform to is 13422 isi marked / ce certified / fda approved, disposable sterile surgical rubber gloves size 7 inches made of natural rubber latex, powder free (polymer /silicon coated), without tear, properly folded in a paper free of holes, with acceptable quality level (aql) of 1.5 or less tensile strength as per en 455-2 should conform to is 13422isi marked / ce certified / fda approved (ce certification / fda approval for item is mandatory for importer firms, that cannot avail is standards, suction catheter, sterile. size: fg 5 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) should conform to is0 8836:2014, suction catheter, sterile. size: fg 6 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) should conform to is0 8836:2014, suction catheter, sterile. size: fg 8 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) should conform to is0 8836:2014, suction catheter, sterile. size: fg 10 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) should co