Get complete information related to latest Usb Drive Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Usb Drive Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Usb Drive Tenders.
Tender For supply of high capacity digital storage media for technical training data recording and analysis 256 gb , removable digital storage media for training equipment and demonstration system 64 gb , aerial imaging and observation module for technical training demonstration and data collection , visual data acquisition and recording system for technical training projects , technical reference publication on artificial intellige application , technical reference publication on unmanned aerial system technology
Tender For supply of machinery and equipment - uv-vis spectrophotometer spectrophotometer should be of true double beam optics system. sample compartment should have dedicated one reference cell holder and one sample cell holder. system should be czerny-turner monochromator with lo-ray-ligh grade blazed holographic grating or equivalent. system should have a light source of 20-w halogen lamp and deuterium lamp. automatic switch over of light source to be possible and auto position adjustment. system should have a fixed spectral bandwidth of 1nm. system should have facility to use as stand-alone keyboard-display and with pc-controlled software. wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be 0.1 nm at d2 656.1 nm & 0.3 nm for entire range. stray light: less than 0.02% at 220 nm (nai)less than 0.02% at 340 nm (nano2) less than 0.5% at 198 nm (kcl) photometric range:absorbance: -4 to 4 abs transmittance: 0% to 400% system should have photometric accuracy : 0.002 abs at 0.5 abs 0.004 abs at 1.0 abs 0.006 abs at 2.0 abs(measured using nist930d/nist1930 or equivalent) system should have a baseline flatness: less than 0.0006 abs (1,100 to 190 nm, one hour after light source turned on) system should have a noise level: less than 0.00005 abs (700 nm). detector should be silicon photodiode only. system should have a usbdrive port to connect the printers or external drives. system should compulsorily have bio-method mode of measurement for determining dna and protein concentrations. quantitates dna or protein using the absorbance at 260/230nm. system should be capable of identification of organic compounds, chemical reaction tracking and enzyme reaction measurement. pc with relevant hardware including monitor keyboard, mouse., fuming hoods the proposed floor-mounted aerodynamic fume hood (1800 1000 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. the system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards ideal for advanced research and chemical handling applications.1) design & compliance aerodynamic structure with automatic bypass airflow system. conforms to ashrae 110:2016 / en 14175 standards, including tracer gas containment test. certified ashrae compliance required 2) construction & materials made of powder-coated galvanized iron (gi, 120 gsm, is 277 compliant) sheet thickness: 1 mm (1.2 mm for structural supports) heavy-duty base frame: 60 40 2 mm phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean ss 304 worktop with 15 mm raised edges for spill containment ss 304 aerodynamic airfoil with anti- corrosive coating 3) dimensions & workspace usable workspace: 1500 mm (w) 850 mm (d) 1180 mm (h) clear viewing height: 1100 mm modular base cabinets with maintenance access 4) coating & finish 8-stage chemical pre-treatment epoxy polyester / polyurethane coating (70 80 microns) corrosion resistance validated by 1000-hour salt spray test 5) functional features vertical sliding toughened glass sash (4 5 mm), counterbalanced openable front top panel for easy maintenance aerodynamic baffle system for efficient fume removal (light to heavy fumes) flow control damper for airflow regulation 6) utilities & safety integrated gas, water, and electrical fittings in corner posts remotely operated, color-coded service valves safety partition between utilities no cable entry below sash (enhanced safety design) electrical fittings: norysis /legrand (230v, 5/16a, 50 hz) 7) accessories pp cup sink with water tap and drainage led lighting with protective enclosure adjustable leveling screws ( 10 mm) storage base cabinets with shelves and self-closing shutters 8) centrifugal blower specifications remote, silent ms + frp blower with chemical-r
Tender For corrigendum : supply of portable pa neckband system, rechargeable with 1 neckband mic with usb and sd card input, black, mp3 player, mounting type-neckband, power source- battery powered, connector type-usb, number of channels 2, audio input 3.5mm mic, 3.5mm line, output wattage-12 watts, item weight unit of measure 0.40 kg- 0.50 kg, built-in mp3 digital player for playback of music through a usbdrive or a tf card; the unit can be used while hanging on the shoulder or by putting around the neck. ]
Tender For corrigendum : supply of rain gauge sensor tbrg with mounting accessories , temperature and humidity sensor with mounting accessories , pressure sensor with mounting accessories , ultrasonic wind sensor with mounting accessories , das with ip-67 compliant enclosure with mounting accessories and usb pen drive 16 gb or more for data retrieval , gprs modem with dual sim slot 4g compatible with 3g or latest facility with minimum 8 dbi antenna gain with mounting accessories , portable aws tripod mast , suitable smf battery for 20 days backup without charging , suitable solar panel for charging the smf battery with mounting accessories on the mast , installation, integration of sensors of aws, masts erection, prototype of earthing for signal ground and lightning arrestor , toolkit for operational and maintenance of aws , data loggers as per technical specification , laptop for data display and transfer purpose , hard copy and soft copy in usbdrive 16 gb of operation and maintenance manuals
Tender For supply and installation of bera system - supply & installa tion of bera system, software and accessories -(specification mentioned as in the notice inviting tender document), specifications ecochg cortical aep (p100, llr, p300, mmn) am lr, eabr vestibular evoke d myogenic potenti al (vemp) algo rithm for emg rec tification assr, stacked abr (if p ossible). transducers - ins ert earphone s -td h headphone -bon e vibra tor - loudsp eaker stimulus - click (user-selecta ble from choi ces of 50, 100, 150, and 200 use) tone bur st (frequenci es 2 50 to 8 khz, choice of linear, henning, blackman or gaussian stimulus ramps for tone burst). t one pip speech: /p a/, /ta/, / ka/ ce- chirp, ce-chirp o cta ve bands mas king noise: pink a nd white noise p olarity: alternating , condensation, rar efaction intensity: 0 to 130 db spl or more repetition rates: 0.2 100 depending on modality data points: 256, 512, 1024 or more test protocols - unlimited, the system must support th e creation of user-d efined custom protocols capable of calculating a numeric correlation of t wo selected wavef orms to define simi larity between the collected waveforms objectively. c apable of performi ng weighted and unweighted addition and subtraction of selected waveforms. capable of sep arating abrdata c ollected with altern ating polarity stimu lation into its separate rarefaction and condensationwave form components. system must sup port automatic elec trode switching for singlechannel data collection such thatmanual movement of electrodesin the electrode cable is n ot required to colle ct ipsilateral data when changing the stimulus ear. syst em must be capabl e of applying user- specified post hoc digital filters durin g data analysis. s ystem must suppor t simultaneous revi ew of data frommultiple test sessions for the patient in th e same on-screen d isplay and report to facilitate monitorin g for changes over time. system mustprovide a means o f password-protecti ng thetransducer c alibration values to prevent inadvertent editing by unautho rised personnel. t he system should h ave an option for external direct printi ng of the report data export to hl7 protocols along wit h the facility to pro vide free api the system should have compliance with international regula tory standards of c e,fda, and iso. free period cali bration for the first three years and afte r three years of cal ibration along with amc support for5 years to be provid ed at the national i nstitute of speech a nd hearing com puter supplied alon g with the equipme nt needed to meet t he below requirem ents latest wind ows operating syst em processor whi ch is intel i 7 or hig her with clock spee d > 2.5mhz ram>= 8 gb and stora ge space ssd>= 5 00gb minimum 3 usb portsalong with 1 hdmi, 1eth ernet port warrant y of the computer b e three years mini mum equipmen t should be powere d using 240v 5ohz. the connection s hould be type d the software sup plied along with th e hardware should have the provision for free upgradation if a new version l aunches in the mar ket within the next five ye ars of the ins tallation also provide free software up dation and support as operating syste m upgradation hap pens penalty for thedelay in repair and delivery of the equipment and acc essories. the penal ty amount is calcul ated based on 24 h ours / 48 hours, an d 72 hours and if t he supplierdoes no t deliver the produc t within ten days of issuing the purchas e order, they should be blacklisted., cmc/amc cost a fter the completion of 3 years of warranty period ( 7 yearsof amc)
Tender For supply installation, testing & commissioning of gps based ohe monitoring & current collection system oliver-g. as per rdso spec no is/rdso-ti/0001:2023 or latest along with all accessories/authentic software as per mentioned specification necessary for mapping with additional power back up. (1) whileproviding complete set of oliver g plus, data loading with one round of testing with consignee person in included with the above item. (2) as per rdso specification supply of laptop with core i 7 with minimum 8 gb ram, 512 ssd hdd, gps for location tracing, and magnet based mounting system. (3) for route mapping provision of the equipment and man power, the location report will be shared to consignee in csv format also loading the new rout data to oliver g system. (4) additional license data logging software will also be provided with above item(5) with magnetic mounting of camera. (6) above the all these specifications the system should capable to detect spark in day time (sun light). [ warranty period: 30 months after the dateof delivery ] ]