Web Analytics Made Easy - StatCounter

Uv Cabinet Tenders

Get complete information related to latest Uv Cabinet Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Uv Cabinet Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Uv Cabinet Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :43030803 Due date: 01 Jan, 202601 Jan, 2026 NA
Tender For corrigendum : supply of supply and installation and commissioning of equipment for ideas lab d d -fpv drone motors , freestyle fpv racing drone motor , brushless motor for drone , outrunner brushless drone motor , magnetic micro coreless motor for micro quadcopters , dc geared motor with encoder , planetary gear dc motor , stepper motor-keyway type shaft , high voltage bus servo , studio grove haptic moto , linear actuator , analog sound level meter , grove speech recognizer , stereo camera , 8mp wide-angle camera module , hydraulic absorbers , pneumatic absorbers , current sensors and sensor brackets , 5 inch raspberry pi screen , cooling fan or heatsinks , dronecan magnetometer , xr dog xiaor geek , bittle x petoi , industrial iot module based on cm4 , waterproof mn601 s 170kv , cs30 rgb d tof camera with solid state lidar and usb connection , depth camera d435 , thermal imaging or fpv diy cameras , x500 v2 kits , pixhawk pro 6c , dof collaborative robotic arm , trito tri023s cc , three axis gimbal camera , mmwave 360 degree fov, weather and environment resistant outdoor or industrial robotics , open source ai robot dog with robot arm , ai robot dog , acoustic modem m16 , s2cr 18 by 34 , matrice 600 pro , blue rov 2 , interactive flat panel monitor 3840x2160 pixels , interactive panel display stand ) /bid number: gem/2025/b/6854003 * /dated: 03-12-2025 & & / bid document1 / 36

CTN :43321988 Due date: 14 Jan, 202614 Jan, 2026 NA
Tender For supply of magnetic stirrers (q4) , uvvis spectrophotometer , ft-ir spectrophotomter with accessories , uhplc versongradient pda fluorescent and ri ditector auto sampler and essential coloums , hplc gradient with uv detector auto sampler and essential coloums , glc with fid detector with head space , atomic absorption spectrophotometer aas with hydride and graphite furnance , potentiometric titrator with necessary electrodes , kf titrator , dissolution apparatus manual , dissolution apparatus with auto sampler , dt apparatus with facility for bolus vaginal tablets and suppository , polari meter digital single wavelength , refractometer digital , melting point apparatus digital , analytical balance 4 digit with printer along with anti vibration table , ph meter digital , hot air oven , vaccum oven , sonicator , centrifuge , uv cabinet , laboratory refrigerator , colorimeter , thermostatic water bath , platinum crucible , muffle furnance digital , water purification system

CTN :43305073 Due date: 03 Jan, 202603 Jan, 2026 NA
Tender For supply of i pad pro 13? (m4) : ultra retina xdr display, 256 gb, 12mp front camera / 12mp back camera, lidar sc

CTN :43185676 Due date: 05 Jan, 202605 Jan, 2026 NA
Tender For purchase of various apparatus/instruments required for department of chemistry, chaudhary ranbir singh university, jind - stirrer- the stirrer should be made up of ceramic coated aluminium alloy top with digital speed and temperature control. the stirring speed should be 50-1500 rpm or better. the stirrer should be operational up to a temperature range of 300oc with an accuracy of 1.0oc and ip 42 protection class. the input power should be 600 w or above. the stirrer should be supplied with hemispheric bowl (100 ml= 1 no; 250 ml= 1 no) to replace oil baths and mantles in order to perform clean and safe analysis with round bottom flasks.warranty must be one year., electronic balance- the electronic balance should have a maximum weighing capacity of 200 g or more with a resolution and repeatability of 0.1 mg, and a response time of 5 sec or better. the system should have automatic internal calibration with touch screen display. the system should have internal database capacity of 2500 or more with multiuser password protection feature. warranty must be one year., vaccum pump - the pump should be operational at a maximum power of 65 w or more with a max. vaccum of 99 mbar or more. the pump should be fitted withvacuum and filter cartridge., hot air oven- the inner chamber should be made of stainlesssteel and the outer chamber should be m.s powdercoated. the maximum capacity of the oven shouldbe 100 ml or more. the operational temperatureshould be between ambient to 250oc or more witha temperature accuracy of 1o c. pid based digitaltemperature control., double distillation unit- the unit should be pyrogen free with a distillation water output capacity of 1.5 l/h. the minimum cooling water requirement should be 1lt/min. auto-power cut facility in case of halted supply of water., circulating oil bath- the oil bath should be made up of stainless steel with 4 digit 7 segment led display for temperature and time. the bath should have s.s perforated tray for holding flasks. the bath should have a capacity to accommodate flask of 1l. the working temperature range should be +5 to 240oc (0.1oc increment) with a temperature stability of 1oc, water bath- the water bath should have a capacity of 20 l within built water level sensor. the bath should be made up of stainless steel and supplied with 8 concentric rings. the bath should have digital temperature control with pt100 sensor. the system should have stirring capability with ptfe magnetic bars., ph/ condutivity meter - operational between a ph range of -2 to 16.00 with a resolution of 0.01 ph and an accuracy of 0.02 ph. 5 points calibration. the ec range shouldbe in between 0.00 to 29.99 s/cm, uv cabinet- operational at two uv wavelengths (254 and 365 nm). the cabinet should also be equipped with one visible light. the external body should be coated with ms powder/epoxy., flame photometer- application: the flame photometer is used for qualitative and quantitative determination of several cations, especially for metals that are easily excited to higher energy levels at flametemperature. these metals include na+, k+, ca2+, ba2+ and li2+.specification requirementmeasuring range na+: 0 to 99.9 ppm k+:0 to 99.9 ppm ca 2+ :0-99.9 ppmli 2+: 0 to 99.99 ppmsensitivity na+= 0.1 ppmk+ = 0.1 ppmspecificity less than 0.5% interference when concentrations are equal to test sample concentrationsgas control-adjustable with knobsignition system-auto ignition systemflame failure-auto detectiongas cut off-automaticreproducibility-less than 1% coefficient of variation for 20 consecutive samplesusing 10 ppm na set as maximum standardlinearity-less than 1%display led, 12.5 mm (1/2")fuel supply-high-grade propane/butane mixture regulated at approximately30 psiair supply-6 l/min at 12 psi; oil and moisture freerecorder-output 0.05 to 5 v (switchable)operating manuals, service manuals, other manuals should provide user, technical and maintenance manuals in english language list of equipment and procedures required
 Loading, Please wait...

Connect us via What's Up