Tender For maintenance of e.i in rb at chandigarh. (addition/ alteration of e.i in house no. 83, sector-23, house no. 320 and 3947, sector-22, chandigarh). - dsr item no. 1.15rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm. frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /pvc conduit including dismantling as required., group a., group b., dsr item no. 2.18 supplying and fixing 20amps, 240 volts, spn industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required., dsr item no. 1.16rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm. frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required., dsr item no. 1.17supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required., 3 x 1.5 sq. mm, 3 x 2.5 sq. mm, 3 x 4 sq. mm, dsr item no.1.21supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required., 25mm, dsr item no.1.23supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required., 5/6 amps switch, 2 way 5/6 a switch, 3 pin 5/6 a. socket outlet, dsr item no. 1.29 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required., dsr item no. 1.30 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required., dsr item no. 1.33supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required., dsr item no.1.38 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required., dsr item no.2.3 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/ isolator), 12 way, double door, dsr item no. 2.4 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (but without mcb/ rccb/ isolator)., 4 way (4 + 12) double door, dsr item no. 2.10 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, "c" curve, miniature circuitbreaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required., single pole, double pole, triple pole and neutral, supply and erection of electronic step type socket type fan regulator in existing b.l. sheet including making connection and petty material reqd. to complete the job. the fan regulator should be of anchor panta / havells reo/ gold medal essenza make only., supply and erection of b.l. holde
Tender For corrigendum : aoh of electrical equipment and auxiliaries of sstpp unit-1 of 2x600mw, sstpp, mppgcl, khandwa. - generator, misc works in generator overhauling, h2 purging after unit shutdown & h2 refilling before of unit light up., transformers, general overhauling of ht transformers, generating transformer(work description as detailed intender schedule), station transformer (work description as detailed intender schedule), inter-connecting transformer (work description as detailed intender schedule), unit auxiliary transformer (work description as detailed intender schedule), neutral grounding panel ( gen., gt, st, uats) {(work description as detailed intender schedule)}, general overhauling of lt transformers, lt dry type transformers (work description as detailed intender schedule), lt oil filled transformers (work description as detailed intender schedule), switchyard, breaker, isolators ,earth switch, bay equipments (cleaning & terminal tightness), bus ducts (work description as detailed intender schedule), 21/ 15.75 kv gen bus duct, 11 kv uat/st bus duct, 6.6 kv uat/st bus duct, lt transformer bus duct, esp, ltmsb & acp buses , ec panels & heater work (as per scope of work), ltmsb & acp breakers (as per scope of work), ltmsb & acp modules(as per scope of work)eerm=80 , cerm=80, gdrm=8, fields= 80, vfd supply=4, lighting supply & etc. = 25(approx), ht switchgear (11 kv/ 6.6 kv), bus cleaning , tightness & complete inspection of all buses., breaker cleaning, tightness & operation checking, bop switchgears panel / local control panels / wall mounted panels and 415v lt swbd/ mcc/acdb/dcdb switchgear panel, bus cleaning , tightness & complete inspection of all buses. breaker cleaning, tightness & operation checking, power house lighting & power supply, cleaning , tightness & complete inspection of all lightning transformers & ldb, providing power supply as per site requirement & for other maintenance work of bmd,tmd etc., ht motors, servicing of ht motors, ht motor cooler (general inspection & cleaning), lt motors servicing, motors above 40 kw, motor 40 kw to 11 kw, motors 10 kw to 5.5 kw, motors 5 kw to 1.1 kw, motors 1 kw and below, esp lt motors 1 kw and below, lt motor overhauling, motors above 40 kw(machining), motor 40 kw to 11 kw, motors 10 kw to 5.5 kw, motors 5 kw to 1.1 kw, motors 1 kw and below, servicing of dc bus, cleaning/servicing of 220 v dcdb buses & modules, servicing of soot blowers, servicing of soot blower motor 1 kw & below, servicing of soot blower panel/modules
Tender For corrigendum : providing of operation and maintenance power house / power plant - complete system 630 kva 11/0.433 kv oil type transformer , 11kv vcb ht breaker pane, 1000amp main lt panel with bus coupler
Tender For ttps es circle em i annual maintenance and testing of wbct breaker las cvt isolators cc wave traps main bus i ii and iii pt cts transfer bus station transformer i ii and spare generator transformer under hung bus earth bus and its frame under hung bu
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - non comprehensive annual maintenance contract for abb make air circuitbreaker of rating up to 1250a of blast furnace for nmdc steel limited; as per tender document; as..
Tender For providing of customized amc/cmc for pre-owned products - nc-amc of air circuitbreaker; as per tender document; annual maintenance contract (amc); as per tender document; no
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, 220kv switchyard three phase manual isolators (ds) preventative maintenance (total quantity 1 is equal to 19 numbers ..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, 220kv switchyard three phase motorized isolators (ds) preventative maintenance (total quantity 1 is equal to 17 numbe..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, assistance in preventative maintenance of three phase 220kv sf6 circuitbreaker (total quantity 1 is equal to 10 numb..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, assistance in preventative maintenance of 220 / 132 kv three phase mocb (total quantity 1 is equal to 2 numbers for t..,repair, main
Tender For corrigendum : 1) providing of separate earth pits (3nos) for las of 132kv bellampally-mandamary-ii feeder and for circuitbreaker (1no) of 1no.132kv bellampally-sirpur kagaznagar-i feeder at 132kv ss bellampally2) erection of 1no new earth pit for ptr-2 at 132kv ss bellampally3) erection of 1no earth pit for ptr-2 at 132kv ss luxettipet4) erection of 2nos.new earth pit for ptr-1,2 at 132kv ss chennur in operation and maintenance division, mancherial in omc circle, adilabad