Web Analytics Made Easy - StatCounter

Vaccum Circuit Breaker Tenders

Get complete information related to latest Vaccum Circuit Breaker Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Vaccum Circuit Breaker Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Vaccum Circuit Breaker Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government / Public Sector

CTN :45742789 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For supply of sf6 gas filing equipment (gas filling device) with regulator suitable to abb make circuit breaker of 145kv double pole and outdoor type . demonstration about equipment usage required at consignee location. [ warranty period: 30 months after the date of delivery ] ]

State Government

CTN :45739189 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - for attending gas leakage of 145kv sf6 gas circuit breaker siemens make at 132kv s/s badagaon etd mau; substation; service provider

Central Government/Public Sector

CTN :45704645 Due date: 17 Jul, 202617 Jul, 2026 4.54 Crore
Tender For dgms approved flp circuit breaker 550v, 400a (vacuum type) gas group i , dgms approved flp vcb 6.6kv, 400a gas group i , dgms approved flp gas group i 5kva, 550v/110v lighting transformer , dgms approved flp tsu 500kva, 6.6kv/550v gas group i

CTN :45233865 Due date: 29 Jul, 202629 Jul, 2026 NA
Tender For corrigendum : supply of lm 2500 module support system-fuel filtering module , gas turbine - coalescer cartridge ca33-3, separator cartridge st629fd, duplex pre-filter- filtering cartridge mp5, brg, plc, filter element, charge pump, spin-on, packing, blade stg 11 wide platform, detector, vsvi, vai-48, vao-8, vdop-24, vlli-24, hose assys: supply pump to filter a & b, filtering basket, actuation hose, 1/4" id x 30"l, process valve & instrument - 1/2" hose assy, process valve & instrument - 3/4" hose assy, power filter, emi, 20a, 50vdc, circuit breaker, 20a 2 poles, vdmc/vme pentium sbc+one pmc card tab 08 (ps322875085268), 5a relay, ecu power supply, rugged panel mount 2in trackball, network interface switch, gasket, instrumentations (pumping skid) - pressure gauge 0 10 bar, loosen components - flow meter prosonic 92f50, instrumentations (filtering skid) - magnetic level indicator

Central Government/Public Sector

CTN :45469070 Due date: 02 Jul, 202602 Jul, 2026 6.75 Crore
Location: Goa - Goa Goa - Goa
Tender For corrigendum : annual operation & day to day maintenance of internal & external e&m installations at goa international airport for the year 2026-2028. - servicing, testing and checking of breakers , "servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 800-1600 a " , "servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 2000 a - 2500a " , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 3200a - 4000a , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. schneider make acb of following rating , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. ge make acb of following rating , one time servicing, checking and testing of 33kv vaccum circuit breakers (vcb) including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. make jyoti , servicing, checking and calibration of the following relays as per recommended standards and submission of calibration report complete as required through authorised agency of oem / agency approved by engineer-in-charge. , servicing of 3x 4kw grundfos make hydropneumatic pumps along with control panel which includes cleaning, safety check, motor, gear box, drive check, vfd parameters check etc. as per oem recommendation through oem or authorised service partner of oem. , servicing of 0.55 kw - 5kw grundfos make pumps which includes cleaning, safety check, motor, gear box, drive check etc. as per oem recommendation through oem or authorised service partner of oem. , dehydration & filteration of transformer oil of 1000 kva transformer of aai residential colony to improve the breakdown voltage of oil up to 50 kv by oil filtration machine and carrying out bdv test of oil, top up of transformer oil etc. by keeping the dehydration equipment out side the 33kv yard including transportation of filtration machine up to site etc. complete as required (excluding the cost of transformer oil). , "the execution of items mentioned in cpwd, delhi schedule of rates (e&m) 2025 for electrical repair and maintenance of electrical e&m installations as and when required as per direction of engineer-in-charge at goa airport for period of two years. agency will quote against basic rate of rs. 5,00,000.00 (say x) (including gst) in ""rate column"" for examples : (i) if bidder is quoting rs. 4,00,000.00 (including gst) (y1) then it will be

State Government

CTN :45687349 Due date: 09 Jul, 202609 Jul, 2026 1.29 Lacs
Tender For attending sf6 gas leakcage of 145kv bus coupler circuit breaker at 132kv sub-staton bhathat under etd-i gorakhpur

State Government

CTN :45694609 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For supply of high dielectric strength and thermal stability sf 6 gas , mccb 3 pole 100a 3ph 415v of standard make , rotary head assembly for smc make isolator , jumper cone for panther conductor , vibration damper for earth wire 7 3.25 mm , single tension fitting for acsr panther , pg clamp panther to panther conductor , ct shorting strip for 36kv ct made of copper , 145kv isolator blade smc make , spring charging motor suitable for 145kv cgl make sf6 cb , 145kv isolator clamp suitable for genandy make for panther conductor , tripping coil for 245kv sf6 circuit breaker

CTN :45679372 Due date: 02 Jul, 202602 Jul, 2026 20.16 Lacs
Tender For supply and replacement of defective parts of kirloskar make transformers of 1000/750/500 kva capacity at ugc & cag building, new delhi. - supply and fixing of over current earth fourth relay 24 dc l&t make etc complete as reqd. , supply and fixing of 11 kv indoor single phase resin cast current transformer 300/5amp etc complete as reqd., , supply and fixing of transformer 500 kva 11/0.433 kv wt1 scanner & rtd sencer lead., , supply & installation of suitable rating of 500 kva 11/0.433 kv lv bussing porcelain or epoxy-cast resin comply with is-1180 complete as required, , supply and fixing of suitable rating of 500 kva 11/0.433 kv lv flexible porcelain or epoxy-cast resin comply with is-1180 complete as required., , dismantling /loading and unloading of 500kva, 11kv/433volt, 3phase, 50hz, cast resin dry type kirloskar make indoor transformer hv/lv coil/core etc and repair of crack in hv/lv winding/core and putting cast resin/resin hardener, reassembling all the dismantle parts accessories confirming to is 11171 and iec 60076 etc including all tests i.e voltage ratio, magnetic balancing, vector group, ir magnetizing current, winding resistance etc complete as reqd., , supply & installation of 630a vcb vacuum interrupter etc complete as reqd., , sh-2 (old cag bldg), , supply and replacement of 750- 1000 kva transformer oil gas kit etc complete as reqd., , checking in 750-1000 kva transformer all type of protection etc complete as reqd., , supply and replacement of lv bushing oil seal in 750-1000 transformer etc complete as reqd. no.ryb) (4, , supply and replacement of hv bushing oil seal in 750-1000 transformer etc complete as reqd. (3 no. r,y, b), , supply and replacement of off load tape changer in 750-1000 kva transformer etc complete as reqd., , replacement of transformer oil in oltc top-up of main tank etc complete as reqd., transformer oil filtration and dehydration of 750 kva & 1000 kva transformer using high-vacuum oil filtration plant, including removal of moisture, dissolved gases, sludge and impurities from transformer oil, circulation of oil through filtration machine, achieving required bdv value, testing before and after filtration, manpower, tools & tackles, consumables, complete as required at site., , complete servicing, overhauling, cleaning, contact checking, lubrication, insulation resistance testing, contact resistance testing, functional testing and commissioning of oil circuit breaker (ocb), complete as required at site., , supply & installation of male contact, , supply & installation of female contact, , supply & installation of over current earth fault relay, , supply & installation of 24 volt dc power pack unit etc complete as reqd., , supply and fixing of transformer wti relay etc complete as reqd.., , supply and replacement of transformer oti relay etc complete as reqd.., , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, ics=100% icu and operational voltage 690v etc. as required., , (make: schneider electric-nsx /siemens / lk/ abb/hager)

corporations/Associations/Others

CTN :45421041 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For corrigendum : supply of closing spring assembly including closing spring, dub bush and spring holder assembly of vm12 breaker , dashpot assembly for 6.6 kv 1250 a vaccum circuit breaker , set of pins for vcb, vm-12, bhel drg nos: 25211001581-002: 3 nos, 25211001581-004: 3 nos, (2521100158 , set of clips for vcb make bhel, type: vm- 12, bhel drg nos: 25211001588- 001: 2 nos, 25211001588- 002 , closing coil/tripping coil (220v dc) for 6.6kv vaccum circuit breaker bhel make type vm 12 , breaker auxiliary 52c/d contact operating leaver assembly with switches 6no+ 6nc for bhel make 6.6kv , breaker auxiliary 52a/b contact operating leaver assembly with switches 6no+ 6nc for bhel make 6.6kv , spring charging motor for vm-12, 7.2kv, indoor vacuum circuit breaker. make: bhel. drg. no. 25211001 , aux switch 16 way , closing unit assembly , rack-in/rack-out handle , service/ test position limit switch , complete assembly of plug and socket(32-pin plug & socket) assembly with interlock. bhel drg no: 352 , tripping spring assembly set bhel drg. 35211001536-v00

State Government

CTN :45425604 Due date: 06 Jul, 202606 Jul, 2026 31.08 Lacs
Tender For corrigendum : sitc of 145kv, sf6, 2500a bus coupler switchgear including c&r panel at ushp-ii, kangan j&k ut . - supply of 132kv control and relay panel for bus coupler simplex/duplex as per requirement, completely wired including substation automation supporting ieds/numerical relays of make abb/siemens/ge micom/alstom/schneider with iec 61850 compatibility, including bus bar protection suitable for min 08 no. bays., supply of 3 pole, sf6 gas filled, outdoor circuit breaker , including all accessories, auxiliaries and marshalling boxes/kiosks, (145kv, 2500 amps or higher, of 3 phase, 50 c/s and 40 ka for 1 second) along with supporting structures etc. complete in all respects ss body,universal spring charging motor with mandatory sparesthis job includes foundation rework/retrofitting, ensuring that the retrofitting process shall not cause any vibration or disturbance to the switchgear structure during its operation., supply of 10 core, 2.5 sq mm, 1100 v, pvc insulated, pvc sheathed, frls, galvanized steel wire/ strip armored stranded copper conductor control cable complete
 Loading, Please wait...

Connect us via What's Up