Get complete information related to latest Vaccum Interruptor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Vaccum Interruptor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Vaccum Interruptor Tenders.
Tender For supply of fixed type air circuit breaker for power cars conforming to iec :60947 (part. 1 & 2) of ra ting 800 amps, 3 pole, 690v, 50 ka breaking capacity with 6 no+ 6 nc auxiliary contact blocks, manu ally operated with under voltage release, earth fault release with 30% i 40% /50% setting and built in cts and arc chute 660 v, thermal magnetic dn 1 auxiliary contact uvi ef release equivalent to drg. abb cat no. e2n800 or ge cat no.rms-9d or l&t cat no. cn-cs 800c as per rcf spec. no. edts-103 rev.d amdt.7. offers from oem or authorized dealers will only be accepted. [ warranty period: 30 months after the date of delivery ]
Tender For supply of molded case circuit breaker (mccb), 100a, 3 pole, rated voltage 415v ac, breaking ca pacity 36 ka with thermal magnetic trip unit confirming to is: 13947 part-ii (latest revision). [ warran ty period: 30 months after the date of delivery ]
Tender For procurement of spares of mineline private limited make flp vcb 3 3kv flp tsu 3 3kv 550v flp acb etc - isolator 400a , vacuum circuit breaker 3.3kv , potential transformer 3.3 kv , hrc ht pt fuse , primary side p.t fuse plate wiring assembly , h.t. control plate wiring assembly , voltmeter , fuse terminal , multicore bushing , indicating lamp , 3.3kv adopter , 3.3kv coupler , bullet pin 3.3kv , hv bushing , dc power pack , neutral monitoring relay with resistance , earth leakage 50 750m a and 750ma 2a dual settings , earth leakage relay 50 750m a with time lag with cbct , overload short circuit and motor protection relay , vcb aux .rotary switch , control relay , ht bushing , vcb shunt trip coil , timer , 3 pole oil dashpot relay , cover bolts , insulator assembly k3 on off , overload assembly breaker 110a 200a , overload assembly breaker 310a 400a , overload coil 200a , short trip assembly complete , shunt trip coils , no volt coil assy. under voltage coil assy. with moulding , catcher assembly , arc chutes , ammeter 200 5 for acb , ammeter 100 5 for acb , ammeter 300 5 for acb , ammeter 400 5 for acb , busbar , potential transformer , brass cone and gland assembly , indicating lamps , power cable for 300a for breaker chamber ic and og , limit switch 2no 2nc for breaker , brass terminal for cp , brass terminal with dmc insulator , terminal bushing insulator dmc incoming 10mmx25mm , on off isolator 300a , split type terminal box , on off isolator 400a , circuit breaker for 100a with complete assy. , circuit breaker for 200a with complete assy. , complete control wiring including pla relay ptds elm7 control fuses control plate wiring harness etc mounted on control plate or circuit breaker for 300a with complete assy , complete control wiring including pla relay ptds elm7 control fuses control plate wiring harness etc mounted on control plate or circuit breaker for 400a with complete assy , earth leakage 50 750m a with time lag , core balance transformer , on off isolator 100a , isolator handle , 1ph 5kva lighting transformer 550 440v sec.110v with mid point earthed , earth leakage relay , brass terminal with dmc bushing , brass stud with dmc bushing for og , magnetic ol relay , thermal ol relay , on delay timer , push button and element , isolator on off rev 100a , pilot relay , switch module , isolator on off rev 200a , on off rev isolator 300a , copper terminal bushing cp og , aux. contactor 220v ac , resistance
Tender For supply of miniature circuit breaker 4 pole of capacity 40 amp, 415 / 440 v, 50 hz, c type confirming t o is : 60898-1 : 2002, , rated insulation voltage (uj ):440v, ac rated impulse withstand voltage (uimp):5 kv, rated short-circuit capacity (lcn) 10 ka, each circuit-breaker shall be marked as per is 60947.2.2003, protection type: l- for overload protection (thermal) & i- for short-circuit protection (magnetic), suitable for panel mounting, screw-type terminals, protection type - l for overload protection (thermal) & i for short-cir cuit protection (magnetic), adjustable thermal-magnetic trip and protection unit, fixed magnetic settings a nd with toggle control. [ warranty period: 30 months after the date of delivery ]
Tender For supply of 16 a protected poles: 4 pole, 10 ka mcb, rated current (in)16a , user value rated operation al voltage (ue ):415v / 440v ac, rated insulation voltage (uj ):440v ac, rated impulse withstand voltage ( uimp):5 ,kv, rated frequency:50 hz, rated short-circuit capacity (lcn):10 ka, instantaneous tripping current : c-type, each circuit-breaker shall be marked as per is 60947.2.2003, protection type - l for overload prote ction (thermal) & i for short-circuit protection (magnetic), adjustable thermal-magnetic trip and protection u nit, fixed magnetic settings and with toggle control [ warranty period: 30 months after the date of deliver y ]
Tender For supply of moulded case circuit breaker four pole (1pole for protected neutral conductor), 415v, ac , of 100a capacity thermo magnetic release type, confirming to iec 60947-ii or is 13947-ii-2003 with ce marking and with the following technical parameters. 1.thermal release setting (for overload prote ction ) adjustable from 70-100% of the rated current. 2. magnetic release setting ( for short circuit ) ad justable 4-10 times of the rated current. 3. breaking capacity of minimum 10 ka ics type. 4. extended terminals [ warranty period: 30 months after the date of delivery ]