Get complete information related to latest Vacuum Motor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Vacuum Motor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Vacuum Motor Tenders.
Tender For supply of field coil assy , drying and distributor unit , starter motor 24 volts , system protection valve , wheel cyl with citradelip 44 45 mm dia , clutch master cylinder 19 05 dia , passenger driver fan 24v
Tender For supply of field coil assy , drying and distributor unit , starter motor 12 volts , starter motor 24 volts , system protection valve , wheel cyl with citradelip 44 45 mm dia , clutch master cylinder 19 05 dia , assy drive shaft , passenger driver fan 24v
Tender For annual tender-2026-27-street light materials supply-veeravanallur town panchayat - insluation gum tape roll - isi, 1/18 vir copper wire [1/44] [90mtr], 3/20 cts copper wire [3/36] [90mtr], 7/20 cts copper wire [7/34] [90mtr], 7/16 cts copper wire [7/67] [90mtr], 19/16 cts copper wire [19/51] [90mtr], 1.5 sq.mm 3 core copper cable, 2.5 sq.mm 3 core copper cable, 4 sq.mm 3 core copper cable, 6 sq.mm 3 core copper cable, 10 sq.mm 3 core copper cable, 16 sq.mm 3 core copper cable, 36w 4pin lamp holder, 36w lamp clip, 24w t5 holder, 20 / 25 mm 1 no gi bend pipe, with 2nos of pole clamps with bolts and nuts, 32 / 40 mm 1 no gi bend pipe, with 2nos of pole clamps with bolts and nuts, 6amps to 32 amps sp mcb, 40amps 2pole isolator, 63amps 4pole isolator, 32a d.p switch, mcb box, fuse unit 16 amps 240v, fuse unit 32 amps 415v, fuse unit 63 amps 415v, fuse unit 100 amps 415v (heavy duty), fuse unit 200 amps 415v (heavy duty), fuse unit 300 amps 415v (heavy duty), fuse unit 400 amps 415v (heavy duty), fuse unit 500 amps 415v (heavy duty), main switches spn 32 amps, main switches tpn 32 amps, main switches tpn 63 amps, main switches tpn 100 amps, main switches tpn 315 amps, 63a 4pmc changeover switch, 100a 4pmc changeover switch, automatic on/off street light timer switch with 24hrs 7 days programable digital timer clock, 40 amps 4 pole contactor with coil, mcb switch and connector fully wired with all accessories, street light meter/main box with wooden board, main switch, fuse carrier fully wired with all accessories, electronic 7 days 24 hrs programable ditial timer clock, 63 amps 4 pole contact with coil, 220v - 250v contactor coil, power capacitor, 9w led bulb, 15w led bulb, 30w led lamp, 36w 4 pin non retrofit type cfl power saver lamp, 36w 4 pin non retrofit type cfl power saver choke, 20w high bright led 4 feet tube light, 20w led power saver street light fitting, 25w led power saver street light fitting, 30w led power saver street light fitting, 36w led power saver street light fitting, 50w led power saver street light fitting, 60w led power saver street light fitting, 80w led power saver street light fitting, 120w led power saver street light fitting, 150w led power saver street light fitting, 100w led power saver flood light fittings, 150w led power saver flood light fittings, 200w led power saver flood light fittings, 40w all-in-one solar led street light fittings, 60w all-in-one solar led street light fittings, 80w all-in-one solar led street light fittings, 18w to 25w led chip board, 30w to 36w led chip board, 45w to 60w led chip board, 72w to 90w led chip board, 120w to 200w led chip board, 18w to 25w led heavy duty electronic driver, 30w to 36w led heavy duty electronic driver, 45w to 60w led heavy duty electronic driver, 72w to 90w led heavy duty electronic driver, 120w to 200w led heavy duty electronic driver, 10 kv surge protector, 48` ceiling fan with all accessories, d.o.l motor starter up-to 10 hp, 10metre hot dip galvanised octogonal pole with round ring arm and 4nos of strong 5feet anchor bolts, templates, and nuts etc.. complete set, 1 hp to 10hp single phase control panel with contactor, relay, auto-start preventor, volt meter, amps meter, etc.. complete in a suitable powder coated enclosure., 5 hp to 7.5hp three phase fasd - auto-start / dry run protection control panel with contactor, relay, auto-start preventor, volt meter, amps meter, etc.. complete in a suitable powder coated enclosure., 10 hp to 25hp three phase fasd - auto-start / dry run protection control panel with contactor, relay, auto-start preventor, volt meter, amps meter, etc.. complete in a suitable powder coated enclosure., service charges automatic on/off street light timer switch box, service charges for mini mast lighting system, service charges for high mast lighting system
Tender For supply of 2.2 kw ac crane drive , 5.5 kw ac crane drive , 11.0 kw ac crane drive , 22.0 kw ac crane drive , 37.0 kw ac crane drive , 55.0 kw ac crane drive , 75.0 kw ac crane drive 3 phase, digital ac crane drive 2.2 kw, ac drive should be suitable for heavy duty operation of 2.2 kw. offered ac drive should be suitable for crane-hoist operation. if, separate software required for crane application, it must be clubbed with supply of material. ac input voltage: 380 to 480v ac 10%, 3 phase, 3 wire, 50 hz; mode of control: bi-directional fully controlled 3-phase ac; speed regulation: 1% of base speed; braking: suitable dynamic braking resistance and chopper unit (external or in-built); acceleration time: 0.1 to 1000s or better; deacceleration time: 0.1 to 1000s or better; overload: 150%-1min, 200%-3.0s; ambient temperature: 0 to 50 c (derating shall not occur below 50 c. in the event that derating occurs below 50 c, the supplier shall provide a higher-rated drive to match the requirement); rated current at 50 c: min. current should be 5.5 amps at 50 c; high starting torque at low speed: 200% starting torque at 0.3 hz; two analog inputs: two nos. analog inputs having signal voltages of 0 to 10 vdc or 4 to 20 ma (configurable); two analog outputs: two nos. analog outputs having signal voltages of 0 to +/-10 vdc or 4 to 20 ma (configurable); six digital inputs: pnp/npn; one relay output: with short-circuit and overload protection; two digital outputs: with short- circuit and overload protection; brake release signals: outputs braking signals based on inverter operating conditions to prevent cargo bed rollback and overrunning; load adaptive control: when the actual load level is lower than the configured load level, the system can be operated at a ratio-multiplied speed (in terms of the configured frequency), resulting in significantly better efficiency; load ) /bid number : gem/2026/b/7563714 * /dated: 20-05-2026 & & / bid document 1 / 29 frequency), resulting in significantly better efficiency; load limiter: maintains the safety and rescuability of suspended loads by stopping when excessive torque is detected and by allowing operation only in the direction opposite to that in which the excessive load was detected; cooling capacity degradation alarm: detects and displays cooling capacity drop due to cooling fin clogging caused by dust and cooling fan airflow reduction; igbt life expectancy forecasting: estimates the power cycle life expectancy of the main circuit s igbt semiconductor device temperature due to frequent acceleration and deceleration stoppages, and displays the estimate before the design life is reached; protection: it must have all standard protections like stall protection, instantaneous power failure, single phasing, over voltage, under voltage, over current, inverter overload, thermal overload etc; display console: it must have alpha numeric display console for programming of drive, fault display and operating condition; dynamic qr code: it must have dynamic qr code for trouble shooting; tuning facility: it must have auto tuning facility. this must enable perfect matching of motor coupled to load with regards to optimum acceleration time, deceleration time, speed regulation etc; drive programming software: suitable drive programming software along with necessary connecting cable and adapter for connection with laptop and drive should be provided to get online with the offered drive (laptop not in scope); automatic voltage regulation: it must have automatic voltage regulation function to maintain high starting torque even at reduced voltage; regenerative option: it must be capable of regenerative operation; communication protocol: modbus (rtu/serial) or ethernet (tcp/ip); make of drives: fuji- electric/yasakawa/schneider/abb only; suitable dynamic breaking resistance unit of 60% wattage rating of drive, however the value of resistance is to be decided by manufacturer as per their technical manual for crane-ho
Tender For quotation for agency are requested to visit site. and submit quotation for supplying and erecting smart all-in-one solar hybrid streetlight with remote lighting management system similar and supplying and erecting smart all-in-one solar hybrid streetlight with remote lighting management system similar ,supply and installation of smart hybrid non-integral solar hybrid streetlight system with system lumen output of 21275 lumens. minimum system efficacy of 185 lm/w, wattage of luminaire should not be more than 115w, supplying and erecting integrated smart street light fitting with lighting management system, 150w ip66 & ik10 class having single piece pressure die-cast aluminium housing, having system lumens output of min. 25500 lumens, min. efficacy of 170 lumen/w, cri>70, cct upto 5700k, thd<10%, p.f. >0.95, operating range of 140-270v, inbuilt surge protection of 10 kv, life class of 75,000 hrs at l70b50 including dimmable driver complete with minimum 5 years warranty, the luminaries should comply with all required iec and is standard lm79 and im 80 ,supply, installation, testing & commssioning of solar high mast with respect to requied lantern carriage, winch, ss rope, motor & other accs. as per site requirment for 16m & 20m high mast.