Tender For supplying installation testing and commissioning of laundry equipment in ashadeep narela delhi - supplying installation testing and commissioning of laundry equipment in ashadeep narela delhi - sitc of front loading washing machine with loading capacity of 30 kg dry weight per charge heavy duty , electrically heater inner basket & outer drum stainless steel, micro countroller base cyclic timer for auto- reserve, auto- timer & auto digital temperature control, water- inlet valve drain valve complete with control panel, & electric motor for wash, driver through pulleys & v- belts and control panel operator on 3ph, 415 v, 50 hz, a.c. supply operation cycle 30 to 40 mintutes complete connection etc as required, sitc of hydro extractor machine direct- driver self- balance with automatic electromangnetic dc injection brake system having capaciy of 30 kg per charge with auto -timed top loading vibration less innner basket and outer drum stainless steel complete with specially designed electric motor and control panel operator on 415 v,3 phase , 50 hz ac supply . operation cycle 5 to 10 mintes complete connection etc as required., sitc of drying tumbler machine front loading open pocket, electrically heater with loading capacity of 30 kg . per charge complete with micro controller base cyclic timer for auto timed & auto - reserver, auto digital temperature control, fitted with control panel , one motor each for driver and blower double walled glass wool insulated outer body mild steel with inner basket stainless steel, self lint screen , v belt driver waster air exhaust etc operates on 415 v, phase 50 hz ac supply . operation cycle 40 to 60 mintes complete connection etc as reqd, supplying and drawing following sizes of frls/hffr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required.a) 3 x 4 sq. mm, b) 6 x 4 sq. mm, supplying and fixing of following capacity, 240/415 volts, 10ka/15ka c series mcbs suitable for lighting and other loads of following poles in the existing mcb db complete with connection, testing and commissioning etc as reqd.a) 40a, 10 ka , fp mcb (415v), b) 63a, 10 ka , fp mcb (415v), supplying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size complete as required.a) 4x 16 sqmm, b) 4x 25 sqmm, supplying, installation, testing & commissioning of led surface mounted batten light of following body material and construction as per is : 10322 with driver (replaceable) as per the requirement with driver efficiency >85%, operating voltage ac 140- 270 volt, frequency 50/60 hz, operating temp range -5 c to 40 c, internal surge protection of 2.5 kv with short & open circuit protection, thd 10%, p. f. 0.95, ip20, cri >80, flicker free, (flicker shouldbe below 5 %), life time (led, driver & electrical circuitry), of minimum 50000 burning hours with 70% of initial lumen maintained till life ends, cct 3000 k / 4000 k / 5700 k /6500 k (as per ansi bin), sdcm(standard deviation colour matching) 3, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard. manufactures word mark/ name engraved/ embossing/ screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy 105 120 lm/watt output . lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90 c). powder coated die cast /extruded aluminium body (thickness > 1.20 mm)a) 40 watt, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in th
Tender For replacement of age old 66kv pneumatic circuitbreaker and c&r panel of 66kv capacitor bank at 220kv r/s hoody. pertaining to tr (op) circle-south, bengaluru on total turnkey basis including supply of all matching materials/equipment including supply of 66kv breakers and erection (including civil works) of all materials/ equipment, testing and commissioning- on percentage basis
Tender For corrigendum : tender description: supply and supervision of etc of 765kv circuitbreakers for ntpc sipat project. - supply- circuitbreaker : 765kv, 50ka for 1s, 25mm/kv creepage, 3150a 3 phase circuitbreaker without pir with control switching capability alongwith support structure, interpole cables, operating mechanism, control boxes and all accessories complete in all respect, supply- circuitbreaker : 765kv, controlled switching device for 3-ph circuitbreaker, supply- circuitbreaker : special cables for cb / csd / rp interfacing. mode of measurement shall be cable-trench running length from circuitbreaker to csd/ relay panel, supply- circuitbreaker : 765kv, foundation bolts for circuitbreaker, platform and ladder, supply- circuitbreaker : laptop for csd, supply- circuitbreaker : 765kv, circuitbreaker operational analyzer with dcrm as per specification, services- circuitbreaker : 765kv, supervision of erection, testing and commissioning of circuitbreaker, services- circuitbreaker : 765kv, supervision of erection testing and commissioning of controlled switching device
Tender For supply of insulation monitoring device as per iec 61557 , insulation fault location system as per iec 61557 , core balance current transformer , condition monitor with integrated gateway , remote alarm indicator , portable insulation fault location system , measuring current transformer , condition monitoring and alarm hmi panel , controller desktop pc of latest configuration , supervision on installation commissioning training charges lumpsum , charges for identifying and locating earth faults in the dc circuit at bhep , replacemen tof dc battery charger 110v statcon for bhepii as per requirement ) /bid number: gem/2025/b/6985112 * /dated: 27-01-2026 & & / bid document1 / 19
Tender For supply of electrical materials for day to day maintenance of ei at balak ram hospital. - supply of 6- 32 amps rating, sp mcb, c curve, 10 ka breaking capacity., supply of 6- 32 amps rating, dp mcb, c curve, 10 ka breaking capacity., supply of 40 amp, 2 pole isolator ., supply of 63 amp, 2 pole isolator ., supply of 63 amp, 4 pole isolator ., supply of 100 amp, 4 pole isolator ., supply of 40 amp rating 2 pole rccb, 30 ma ., supply of 63 amp rating, 4 pole rccb, 30ma ., supply of 20 a, spn, industrial type socket outlet, with plug top and metal chained cover in sheet steel enclosure., supply of 25 mm dia isi marked, pvc conduit, supply of pvc batten / angle holder., supply of 2+6 way, spn, single door, mcb db, supply of 2+2 way, spn, single door, mcb db, supply of 4 way (4 + 12), tpn, mcb db, double door horizontal type., supply of 6 way (4 + 18), tpn, mcb db, double door horizontal type., supplying of led recessed/surface down lighter (round /square/ rectangular) smd type of following body material with pmma and prismatic diffuser and construction as per is : 10322 with driver as per the requirement with driver efficiency >85%, operating voltage ac 140-270 volt, freq 50/60 hz, operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 kv with short & open circuit protection ,thd 10% , p. f. 0.95, ip20, cri >80, ugr (unified glare rating) 19, flicker free, (flicker should be below 5 %), life time (led,driver & electrical circuitary), life time of minimum 50000 burning hours with , 70% of initial lumen maintained till life ends as per lm80 extrapolation ies tm-21-11 report, cct 3000 k / 4000 k / 5700 k / 6000 k /6500 k (as per ansi bin) , sdcm(standard deviation color matching) 3, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard and trade mark certificate ( t.c.). manufactures word mark/ name engraved/ embossing/ screen printing on housing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. complete in all respect i/c connections with 1.5 sq mm frls, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy 105 and 120 lm/watt output . lm79 & lm80 test report from nabl lab for all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90 c). powder coated die cast /extruded aluminium body including trim with aluminium reflector. 12 -15 watt, supplying of panel light 2x2 ft., of following body material and construction as per is : 10322 with driver as per the requirement with driver efficiency >85%, operating voltage ac 140-270 volt, freq 50/60 hz, operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 kv with short & open circuit protection,thd 10% , p. f. 0.95, ip20, cri >80, ugr (unified glare rating) 19, flicker free, (flicker should be below 5 %), life time (led,driver & electrical circuitary), of minimum 50000 burning hours with , 70% of initial lumen maintained till life ends ,cct 3000 k / 4000 k / 5700 k /6000 k/6500 k (as per ansi bin), sdcm(standard deviation color matching) 3, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard and trade mark certificate (t.c.). manufactures word mark/ name engraved/ embossing/ screen printing on housing. complete in all respect i/c connections with 1.5 sq mm frls, pvc insulated copper conductor single core cable and earthing etc. as required withminimum 5 year oem warranty. system lumen efficacy >135 lm/watt output . lm79 & lm80 test report from nabl lab for all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by eng
Tender For supply and installation of microprocessor based intelligent automatic circuitbreaker panel fire protection and detection system in 33kv 11kv control panel at mrss main substation dhori area.