Tender For supply of gulmay x ray machine spares required d d - spare xray on-off sw assy-part no as1090 mp1 , mp1- spare lampholder-part no as1091 mp1 , mp1-spare fuse kit-part no as3867 mp1 , mp1-led spares kit 01-part no as1092 mp1 , key switch-3 pos-part no h271 , lead mp1 cpu i byo-part no as1077 mp1 , mp1 control panel assy mp1 by23 with ict-part no as1952 mp1 , f010 fuse-high speed-63a-part no f010 fuse , f002 fuse-1a-anti surge- part no f002 fuse , f003 fuse-5a-part no f003 fuse , h060 fan-axial -230v-ac-120mm-part no h060 fan , d025 diode-rectifier module-1200v-part no d025 diode , sc03 module-thyristor-double-part no sc03 module , h223 switch-thermal-80deg-n byc-part no h223 switch , cp control pcb assy cp160 by225 by320-part no as0067 , smt dual f byb pcb assy cp160-part no as4009 , cp igbt drive and sensing pcb spare-part no as2070t , cp igbt cont pcb assembly cp160 by320-part no as2083 , cp commutating cap pcb ass spare-part no as0088t , pcb- gx-drive spare-part no as4600t , cp heatsink sense pcb assy spare-part no as0086t , blanking plug-r24-part no res059
Tender For supply of as per boq d d - main lt panel indoor type with fp ai high safety mode technology , apfc capacitor panel 1250 kvar indoor type with aluminium tp , vacuumcircuitbreaker panel 11 kva 800 amp and vcb panel , transformer 3500 kva input voltage 11 kv output voltage 415 v , earthing arrangement copper plate earthing with 50 kg of chemical earthing transformer - 3500 kva technical specification- 1- capacity : 3500 kva, 2- input voltage : 11 kv, 3- output voltage : 415 v, 4- number of phase : 3 phase 5- applicable standard : standard, 6- number of winding : 02 nos, 7- installation type : outdoor, 8- cooling type : onan, 9- terminal arrangement : bare, bushing for hv side & 10- cable box for lv side., 11- vector group : dyn 11, 12- ambient temperature : 50 c, 13- temperature rise of oil : 40 c, 14- temperature rise of winding : 45 c, 15- impedance : 6.25% (subject to +/-10% tolerance), 16- transformer oil : "a grade" tested & certified as per is:335 standard., 17- no load losses : as per is standard, 18- full load losses : as per is standard, 19- copper : pure electrolytic grade, 20- tapping mode 01 nos - rotary type off circuit tap changer (octc) with locking arrangement & tap indication., 21- basic insulation leve for hv : 75 kv peak / 28 kv rms, 22- basic insulation level for lv : - / 3 kv rms, 23- tapping range +5% to -5% in steps of 2.5% by off circuit tap changer (octc)., (a) earthing arrangement (1) copper plate earthing 600x600x6 mm with 50 kg of chemical compound depth around 10 meter with testing pit. (2) gi plate earthing 600x600x6 mm with 50 kg of chemical compound depth around 4 meter with testing pit. (3) copper strips 50*6 (4) gi strips 50*6 make premium, (b) cables and accessories (1) 3 c x 240 sqmm al armoured ht cable (2) joint kit (3) 3.5 c x 400 sqmm al ) /bid number : gem/2025/b/6768705 * /dated: 17-10-2025 & & / bid document 1 / 19