Get complete information related to latest Vacuum Contactor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Vacuum Contactor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Vacuum Contactor Tenders.
Tender For supply of isolator 400amps 3 3kv reversing part no ht100b , isolator 200 amp 3 3 kv on off part no ht100 , isolator fixed contact set part no ht1001 , isolator moving contact set part no ht1002 , vacuumcontactor 400 amps 3 3kv part no ht200 , bridge rectifier unit complete part no ht005 , vacuum interrptor 3 3kv 400a part no ht202 , bottle for vaccum contractor 400 amps 3 part no 201 , vaccum contactor holding coil 110v dc part no 204 , auxiliary switch for vaccum contractor 2 part no 205 , p t 40va 0 8 12v 0 110v part no 206 , auxiliary contactor 3no 1nc 110v ac part no 208 , resin cast p t 750va 3 3kv 110v single part no 300 , isolator handle on off with axel bush part no 1501 , ht control fuse 3 3 kv 2 amps part no 400 , resin cast moulded cbct part no 500 , e l unit complete without transformer part no 800 , single phase preventer cup 20 pfr make part no 2001 , ct oprted ct sec 5a motor prtectn relay part no ht900e , o l rly thrml 4 7 5a ct oprtd w mntng part no 900b , 72sq mm ammeter 0 150 450a part no ht1000 , 72sq mm voltmeter 0 5kv part no ht1100 , ammeter selector switch part no 1001 , hrc fuse base carrier for control part no 1200 , hrc fuse link 4a for control part no 1201 , push button with element for start sto part no ht1300 , lamp holder with lamp on off trip part no ht1400 , power hrc fuse part no 1500 , brass cable gland complete with c i clam part no 1600 , copper bus bar 400 amps set of 3 part no ht101 , undervoltage relay part no ht2000 , static type idmtl over current and short part no ht900a , pilot realy 12dc part no ht2200 , voltmeter selector wsitch part no ht1101 , contactor tp 12 amps ac3 duty fitted wit part no ht200a
Tender For : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of spares for diese
Tender For supply of cu bus bar, pvc slvd 25x8 w-cable clamp part no. cb480kwbbr400 , isolator on off reverse part no. ioor480kwp3ir , vacuumcontactor 3.3 kv, coi l - 220v ac part no. vc480kwsavac4 , closing coil of vacuum contractor part no. ccvc480kwvcccc , current transformer part no. ct480kwstd , earth leakage relay , 220vac w-cbt 80mm2 part no. elr480kwelm8 , ammeter part no. am480kwpa1100 , push buttons actuator green-red part no. pba480kwpb , led indicator lamp- green part no. lilg480kw110vac , led indicator lamp- red part no. lilr480kw110vac , led indicator lamp- amber part no. lila480kw110vac , aux contactor _2no plus 2nc_ 220v ac part no. ac2nonc480kwka , electronic timer part no. et480kwbo2aodt5 , thermal o-l with spp part no. tol480kw3ua50001f , o-g and t-g brass cone part no. ogtgbc480kwsg35 , dc pack for closing coil part no. dcpcc480kwpsm , motor protection relay part no. mpr480kw220vac , limit switch for isolator part no. lsfi480kwei , ht hrc fuse part no. hthrc480kw100a , ht pt fuse part no. htptf480kwavt , ht pt fuse support part no. htptfs480kwbs45fs , vcc aux. contact part no. vac480kwvccacb , 1 ph pt 3.3- 110v i 110v ac part no. 1phpt480kwb2spf2v , control fuse part no. cf480kwns , voltmeter ptr 3.3 - 220v part no. vmptr480kw220v , under voltage, over voltage relay part no. uvovr480kw220v , pneumatic on delay timer part no. podt480kw30sec , ht bushing for outgoing part no. htbo480kwhttb10 ) /bid number : gem/2026/b/7476383 * /dated: 04-05-2026 & & / bid document 1 / 26
Tender For corrigendum : supply of spares of prabhu make ht starters for mcl basundhara area : : 5 =5 = - isolator 630a 6 point 6kv on off earth , isolator fixed contact set of 3 , isolator moving contact set of 3 , vaccum contactor 400amp 6 point 6kv grade , diode by255 for vacuumcontactor , bottle f vcum cntctr 400amps 6 point 6kv , vacuumcontactor closing coil 110v dc , auxiliary switch for vacuumcontactor 2n , auxiliary contactor 3no and 1nc 110v , dmc mldd 6 point 6kv insltr fuse , earth leakage relay 30ma 3a w time delay , p t 50va pri 0 110v sec 0 8 12v , ammeter 96sq mm , ammeter selector switch , voltmeter 96sqmm , voltmeter selector switch , push button with element for start sto , lamp holder with lamp on off trip , timer electronics 3sec to 3min on delay , relay overvoltage and undervoltage